Muscle activation during traditional laparoscopic surgery compared with robot-assisted laparoscopic surgery: a meta-analysis

被引:17
|
作者
Hislop, Jaime [1 ]
Tirosh, Oren [2 ]
McCormick, John [3 ]
Nagarajah, Romesh [4 ]
Hensman, Chris [5 ,6 ]
Isaksson, Mats [1 ]
机构
[1] Swinburne Univ Technol, Dept Mech Engn & Prod Design Engn, Melbourne, Vic, Australia
[2] Swinburne Univ Technol, Sch Hlth Sci, Melbourne, Vic, Australia
[3] Swinburne Univ Technol, Ctr Transformat Media Technol, Melbourne, Vic, Australia
[4] Swinburne Univ Technol, Sch Software & Elect Engn, Melbourne, Vic, Australia
[5] Monash Univ, Dept Surg, Melbourne, Vic, Australia
[6] Univ Adelaide, LapSurg Australia, Melbourne, Vic, Australia
关键词
Electromyography; Musculoskeletal disorders; Robot-assisted laparoscopic surgery (RALS); Traditional laparoscopic surgery (TLS); MUSCULOSKELETAL DISORDERS; ERGONOMICS; FATIGUE; TASKS; DESIGN;
D O I
10.1007/s00464-019-07161-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The repetitive and forceful motions used by operating surgeons increase the risk of developing musculoskeletal disorders. Most ergonomists consider the surgical environment to be incredibly harsh for its workers. Traditional Laparoscopic Surgery (TLS) in particular has a number of physical and mental challenges associated with it, and while Robotic-Assisted Laparoscopic Surgery (RALS) provides several features that improve upon TLS, some surgeons have still reported musculoskeletal symptoms they attribute to RALS. In this paper, we endeavored to systematically review muscle activation for both TLS and RALS, to compare the modalities and present the results as a meta-analysis. Methods A literature search was conducted using Pubmed, Embase, and Cochrane databases in November 2018 with the following inclusion criteria: full text was available in English, the paper contained original data, EMG was one of the primary measurement techniques, and the paper included EMG data for both TLS and RALS. Results from studies were compared using standardized mean difference analysis. Results A total of 379 papers were found, and through screening ten were selected for inclusion. Sample populations ranged from 1 to 31 surgeons, and a variety of study designs and metrics were used between studies. The biceps were the only muscle group that consistently and significantly demonstrated lower muscle activation for RALS for all included studies. Conclusions The results may support the belief that RALS is ergonomically superior to TLS, shown through generally lower muscle activation scores. However, these results must be interpreted with caution due to the heterogeneity between the studies and multiple potential sources for bias within studies. This analysis would be strengthened with a higher number of homogenous, high-quality studies examining larger sample sizes.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [1] Muscle activation during traditional laparoscopic surgery compared with robot-assisted laparoscopic surgery: a meta-analysis
    Jaime Hislop
    Oren Tirosh
    John McCormick
    Romesh Nagarajah
    Chris Hensman
    Mats Isaksson
    [J]. Surgical Endoscopy, 2020, 34 : 31 - 38
  • [2] Meta-analysis of Robot-assisted Versus Laparoscopic Surgery for Rectal Cancer
    Ohtani, Hiroshi
    Maeda, Kiyoshi
    Nomura, Shinya
    Shinto, Osamu
    Mizuyama, Yoko
    Nakagawa, Hiroji
    Nagahara, Hisashi
    Shibutani, Masatsune
    Fukuoka, Tatsunari
    Amano, Ryosuke
    Hirakawa, Kosei
    Ohira, Masaichi
    [J]. IN VIVO, 2018, 32 (03): : 611 - 623
  • [3] Robot-assisted laparoscopic surgery versus conventional laparoscopic surgery in randomized controlled trials: A systematic review and meta-analysis
    Roh, Hyunsuk Frank
    Nam, Seung Hyuk
    Kim, Jung Mogg
    [J]. PLOS ONE, 2018, 13 (01):
  • [4] Robot-assisted versus laparoscopic-assisted surgery for colorectal cancer: a meta-analysis
    Zhang, Xuan
    Wei, ZhengQiang
    Bie, MengJun
    Peng, XuDong
    Chen, Cheng
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (12): : 5601 - 5614
  • [5] Robot-assisted versus laparoscopic-assisted surgery for colorectal cancer: a meta-analysis
    Xuan Zhang
    ZhengQiang Wei
    MengJun Bie
    XuDong Peng
    Cheng Chen
    [J]. Surgical Endoscopy, 2016, 30 : 5601 - 5614
  • [6] A systematic review and meta-analysis compared the safety and effectiveness of the AirSeal system with traditional pneumoperitoneum systems in robot-assisted laparoscopic urologic surgery
    Wen, Zhi
    Zhang, Yu
    Yang, Yan-xin
    Yang, Le
    [J]. JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [7] Robot-assisted surgery versus conventional laparoscopic surgery for endometrial cancer: a systematic review and meta-analysis
    Xie, Weimin
    Cao, Dongyan
    Yang, Jiaxin
    Shen, Keng
    Zhao, Lin
    [J]. JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2016, 142 (10) : 2173 - 2183
  • [8] Robot-assisted surgery versus conventional laparoscopic surgery for endometrial cancer: a systematic review and meta-analysis
    Weimin Xie
    Dongyan Cao
    Jiaxin Yang
    Keng Shen
    Lin Zhao
    [J]. Journal of Cancer Research and Clinical Oncology, 2016, 142 : 2173 - 2183
  • [9] Laparoscopic surgery versus robot-assisted surgery for choledochal cyst excision: A systematic review and meta-analysis
    Zhang, Ke
    Zhao, Difang
    Xie, Xiaolong
    Wang, Wentao
    Xiang, Bo
    [J]. FRONTIERS IN PEDIATRICS, 2022, 10
  • [10] Comparison of robot-assisted surgery, laparoscopic-assisted surgery, and open surgery for the treatment of colorectal cancer A network meta-analysis
    Sheng, Shihou
    Zhao, Tiancheng
    Wang, Xu
    [J]. MEDICINE, 2018, 97 (34)