H2S and VOCs abatement robustness in biofilters and air diffusion bioreactors: A comparative study

被引:71
|
作者
Lebrero, Raquel [1 ]
Rodriguez, Elisa [1 ]
Martin, Maria [2 ]
Garcia-Encina, Pedro A. [1 ]
Munoz, Raul [1 ]
机构
[1] Univ Valladolid, Dept Chem Engn & Environm Technol, E-47011 Valladolid, Spain
[2] Univ Girona, Lab Chem & Environm Engn LEQUIA, E-17071 Girona, Spain
关键词
Air diffusion bioreactor; Biofiltration; Odour treatment; Robustness; VOC biodegradation; WASTE-WATER TREATMENT; MASS-TRANSFER COEFFICIENTS; ODOR CONTROL; BIOTRICKLING FILTERS; POLLUTION CONTROL; ACTIVATED-SLUDGE; OPERATING-CONDITIONS; TOLUENE; TEMPERATURE; PERFORMANCE;
D O I
10.1016/j.watres.2010.05.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The robustness of a conventional biofilter and an air diffusion bioreactor (ADB) was comparatively evaluated in laboratory-scale plants treating a mixture of H2S, butanone, toluene and alpha-pinene at gas residence times of 50 s. Under steady state conditions, H2S, butanone and toluene were almost completely degraded, while alpha-pinene removal did not exhibit removal efficiencies (REs) higher than 11.0 +/- 2.3%. Fluctuations in temperature from 8 degrees C to 30 degrees C did not impact significantly process performance in any of the biotechnologies tested. However, while the ADB unit was able to cope with three and six fold step increases in pollutant loadings, volatile organic compounds (VOCs) REs noticeably decreased in the biofilter when subjected to a six fold step change (i.e. 90% reduction for butanone and 30% for toluene). A process shutdown of five days resulted in the temporary loss of butanone and toluene RE in the ADB system. A lack of irrigation during five days caused a slight decrease in the biofilter REs, while a failure in the pH control system drastically affected the ADB performance. Finally, process robustness was quantified. The calculated overall risks showed that both biotechnologies were reliable for H2S and VOCs treatment in wastewater treatment plants, ADB diffusion exhibiting a higher robustness towards fluctuations commonly found under routine operation. This robustness was further confirmed by the high stability of the DGGE profiles. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3905 / 3914
页数:10
相关论文
共 50 条
  • [1] H2S abatement during air drilling of geothermal wells
    Bedell, Stephen A.
    Hammond, C.Alan
    [J]. Bulletin. Geothermal Resources Council, 1988, 17 (08): : 13 - 14
  • [2] H2S emission abatement
    Nagl, Gary J.
    [J]. Pollution Engineering, 2010, 42 (05) : 38 - 41
  • [3] Comparison of autotrophic and mixotrophic biofilters for H2S removal
    Chung, YC
    Huang, CP
    Pan, JR
    Tseng, CP
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1998, 124 (04): : 362 - 367
  • [4] CHELATION CHEMISTRY IN GEOTHERMAL H2S ABATEMENT.
    Bedell, Stephen A.
    Hammond, C.Alan
    [J]. Bulletin. Geothermal Resources Council, 1987, 16 (08): : 3 - 6
  • [5] The removal of H2S from process air by diffusion into activated sludge
    Moussavi, G.
    Naddafi, K.
    Mesdaghinia, A.
    Deshusses, M. A.
    [J]. ENVIRONMENTAL TECHNOLOGY, 2007, 28 (09) : 987 - 993
  • [6] Explosions limits of H2S/CO2/air and H2S/N2/air
    Pahl, R
    Holtappels, K
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2005, 28 (07) : 746 - 749
  • [7] PHOTOIONIZATION STUDY OF (H2S)2 AND (H2S)3
    PREST, HF
    TZENG, WB
    BROM, JM
    NG, CY
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (26) : 7531 - 7536
  • [8] H2S abatement in geothermal plants: Evaluation of process alternatives
    Sanopoulos, D
    Karabelas, A
    [J]. ENERGY SOURCES, 1997, 19 (01): : 63 - 77
  • [9] COST EFFECTIVE ALTERNATIVE FOR H2S ABATEMENT IN THE GEYSERS.
    Vestal, Ken
    [J]. Bulletin. Geothermal Resources Council, 1985, 14 (10): : 7 - 10
  • [10] COMPARATIVE STUDY OF PACKING MATERIALS FOR H2S REMOVAL BY BIOFILTRATION
    Charron, I.
    Zozor, P.
    Renner, C.
    Jovic, M.
    [J]. BIOTECHNIQUES FOR AIR POLLUTION CONTROL, 2010, : 199 - 200