Spatial Beam Shaping for Femtosecond Laser in Vitreo-Retinal Surgery

被引:0
|
作者
Hansen, A. [1 ]
Ripken, T. [1 ]
Krueger, A. [1 ]
机构
[1] Laser Zentrum Hannover, Biomed Opt Dept, Hannover, Germany
关键词
D O I
10.1515/bmt-2012-4133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In ophthalmic surgery, femtosecond laser pulses provide a high precision tool for tissue dissection in the anterior part of the eye with little peripheral implications. However, for an application in the posterior part the precision is diminished by the aberrations of the eye which also cause higher pulse energy required for photodisruption. In order to increase the precision and decrease the pulse energy for vitreo-retinal surgery an adaptive optics system was designed for spatial beam shaping of femtosecond laser pulses. A Hartmann-Shack-Sensor was used for aberration measurement and a deformable mirror for aberration correction. The influence of an adaptive optics aberration correction on the resulting wave front and incision process was investigated in an eye model. The adaptive optics system designed for the requirements of vitreo-retinal surgery provides a wave front correction with diffraction limited precision. The spatial confinement as a consequence of the corrected wave front decreases the pulse energy for the incision process in the model eye. As less energy is required for the incision process adaptive optics in a femtosecond laser scalpel potentially allow for tissue dissection with reduced peripheral damage. This offers new possibilities for non-invasive high precision surgery in the posterior eye segment and the treatment of vitreal and retinal pathologies.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 50 条
  • [1] Vitreo-retinal surgery
    F. Koerner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 (10) : 1071 - 1072
  • [2] VITREO-RETINAL SURGERY
    LEUENBERGER, PM
    SCHWEIZERISCHE RUNDSCHAU FUR MEDIZIN PRAXIS, 1980, 69 (32): : 1134 - 1137
  • [3] Anaesthesia in vitreo-retinal surgery
    Absalom, A
    Mitchell, E
    Goldsmith, C
    Burton, R
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (04) : 316 - 317
  • [4] Robotics in Vitreo-Retinal Surgery
    Ramamurthy, Srishti Raksheeth
    Dave, Vivek Pravin
    SEMINARS IN OPHTHALMOLOGY, 2022, 37 (7-8) : 795 - 800
  • [5] VITREO-RETINAL SYMPOSIUM - REVOLUTIONS IN RETINAL SURGERY
    FISON, LG
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1977, 97 (JUL): : 224 - 224
  • [6] Cytologic analysis in vitreo-retinal surgery
    Benisty, D.
    Hayate, F.
    Boulagnon, C.
    Ducasse, A.
    Arndt, C.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [7] Cytologic analysis in vitreo-retinal surgery
    Arndt, C.
    Ducasse, A.
    Diebold, M. C.
    Boulagnon, C.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [8] Anaesthetic management in vitreo-retinal surgery
    Dal, D
    Aykut, T
    Demirtas, E
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (10) : 830 - 831
  • [9] Controversies in Anticoagulant Therapy in Vitreo-Retinal Surgery
    Grzybowski, Andrzej
    Kupidura-Majewski, Konrad
    Kupidura, Paulina
    CURRENT PHARMACEUTICAL DESIGN, 2015, 21 (32) : 4661 - 4666
  • [10] Indications of the Modern Vitreo-Retinal Surgery Techniques
    Talu, S. D.
    Lazan, N.
    Lupascu, S.
    Sebestyen, E.
    Toader, L.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 15 - 18