DES study of blade trailing edge cutback cooling performance with various lip thicknesses

被引:46
|
作者
Effendy, M. [1 ]
Yao, Y. F. [2 ]
Yao, J. [3 ]
Marchant, D. R. [4 ]
机构
[1] Univ Muhammadiyah Surakarta, Dept Mech Engn, Jln Ahmad Yani,Tromol Pos 1, Kartasura 57102, Surakarta, Indonesia
[2] Univ W England, Dept Engn Design & Math, Coldharbour Lane, Bristol BS16 1QY, Avon, England
[3] Lincoln Univ, Sch Engn, Brayford Pool LN6 7TS, Lincs, England
[4] Kingston Univ London, Fac Sci Engn & Comp, Penrhyn Rd, Kingston Upon Thames KT1 2EE, Surrey, England
关键词
Detached-eddy simulation; Effects of lip thickness to slot height ratio; Thermal mixing process; Blade trailing-edge cutback cooling; DETACHED-EDDY SIMULATIONS; HEAT-TRANSFER; UNIFORM-DENSITY; SLOT; ARRAYS; INJECTION; FLOW;
D O I
10.1016/j.applthermaleng.2015.11.103
中图分类号
O414.1 [热力学];
学科分类号
摘要
Three-dimensional detached-eddy simulation (DES) study has been carried out to evaluate the cooling performance of a trailing-edge cutback turbine blade with various lip thickness to slot height ratios (t/H). By adopting the shear-stress transport (SST) k-omega turbulence model, the numerical investigations were performed at two successive steps: first, to validate simulation results from an existing cutback turbine blade model with staggered circular pin-fins arrays inside the cooling passage against experimental measurements and other available numerical predictions; second, to understand the effects of the lip thickness to the slot height ratio on the blade trailing-edge cooling performance. It was found from the model validations that at two moderate blowing ratios of 0.5 and 1.1, DES predicted film cooling effectiveness are in very good agreement with experimental data. Further comparisons of four various t/H ratios (t/H = 0.25, 0.5, 1.0, 1.5) have revealed that the thermal mixing process between the 'cold' coolant gas and the 'hot' mainstream flow in the near wake region of the exit slot has been greatly intensified with the increase of the t/H ratio. As a result, it causes a rapid decay of the adiabatic film cooling effectiveness downstream of the blade trailing-edge. The observed vortex shedding and its characteristics in the near wake region are found to play an important role in determining the dynamic process of the 'cold' and the 'warm' airflow mixing, which in turn have significant influences on the prediction accuracy of the near-wall heat transfer performance. As the four t/H ratio increases from 0.25 to 1.5, DES predicts the decrease of main shedding frequencies as f(s) = 3.69, 3.2, 2.21, and 1.49 kHz, corresponding to Strouhal numbers S-t = 0.15, 0.20, 0.23, and 0.22, respectively. These results are in good agreement with available experimental measurements. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:434 / 445
页数:12
相关论文
共 50 条
  • [1] Film Cooling Performance on the Trailing Edge Cutback of Turbine Blade with Various Slot Inner Angles
    Chen, Mingfeng
    Ling, Changming
    Zhang, Yuwen
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON COMPUTER MODELING AND SIMULATION (ICCMS 2018), 2017, : 192 - 196
  • [2] Effects of blowing ratios and lip thicknesses on film cooling for trailing edge cutback with latticework ducts
    Jia Q.
    Du W.
    Li X.
    Luo L.
    Jiao Y.
    Yan H.
    Applied Thermal Engineering, 2024, 252
  • [3] DDES study on a pressure-side cutback cooling turbine blade with a whisker lip and a whisker trailing edge
    Luo, Yuxi
    Wen, Fengbo
    Wang, Songtao
    Wang, Zhongqi
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024, 85 (05) : 739 - 760
  • [4] Large eddy simulation study on trailing edge cutback cooling with a whisker lip
    Luo, Yuxi
    Wen, Fengbo
    Sullivan, Pierre
    Wang, Songtao
    Wang, Zhongqi
    International Journal of Heat and Mass Transfer, 2022, 194
  • [5] Large eddy simulation study on trailing edge cutback cooling with a whisker lip
    Luo, Yuxi
    Wen, Fengbo
    Sullivan, Pierre
    Wang, Songtao
    Wang, Zhongqi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 194
  • [6] Detached eddy simulation of blade trailing-edge cutback cooling performance at various ejection slot angles
    Effendy, M.
    Yao, Y. F.
    Yao, J.
    Marchant, D. R.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2019, 80
  • [7] DES study of the unsteady flow and film cooling at trailing edge cutback with various internal rib configurations
    Jia, Qiankun
    Du, Wei
    Luo, Lei
    Yan, Han
    Li, Xingchen
    Jiao, Yinghou
    Wang, Songtao
    AEROSPACE SCIENCE AND TECHNOLOGY, 2024, 145
  • [8] Cutback squealer tip trailing edge cooling performance
    Lu, S.
    Ma, H.
    Zhang, Q.
    Teng, J.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 154
  • [9] NUMERICAL STUDY ON FILM COOLING AND CONVECTIVE HEAT TRANSFER CHARACTERISTICS IN THE CUTBACK REGION OF TURBINE BLADE TRAILING EDGE
    Xie, Yong-Hui
    Ye, Dong-Ting
    Shen, Zhong-Yang
    THERMAL SCIENCE, 2016, 20 : S643 - S649
  • [10] Investigations into film cooling and unsteady flow characteristics in a blade trailing-edge cutback region
    Gao, Yan
    Yan, Xin
    Li, Jun
    He, Kun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (10) : 5015 - 5029