Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances-Part 1: Particulate and gaseous emissions

被引:3
|
作者
Trojanowskia, Rebecca [1 ,2 ]
Lindberga, Jake [1 ,3 ]
Butcher, Thomas [1 ]
Fthenakisa, Vasilis [1 ,2 ]
机构
[1] Brookhaven Natl Lab, Interdisciplinary Sci Dept, Energy Convers Grp, Bldg 815,Rutherford Dr, Upton, NY 11973 USA
[2] Columbia Univ, Dept Earth & Environm Engn, New York, NY USA
[3] SUNY Stony Brook, Dept Mat Sci & Chem Engn, Stony Brook, NY 11794 USA
基金
芬兰科学院;
关键词
SMALL-SCALE COMBUSTION; SOURCE APPORTIONMENT; BLACK CARBON; WOOD COMBUSTION; FINE-PARTICLE; FOSSIL-FUEL; PM2.5; MATTER; HOUSEHOLD; AEROSOLS;
D O I
10.1080/10962247.2022.2044409
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled-elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements. Implications: In this work we provide information on the particulate and gaseous emissions from two wood fired outdoor hydronic heaters. The units were tested using an integrated duty cycle test method that captured cold starts, reload, cyclic and modulating periods between 15 and 100% of maximum rated output. The data and results show a much higher emission factor than those reported by current certification test methods but are more representative of how the units operate in the field.
引用
收藏
页码:738 / 761
页数:24
相关论文
共 4 条
  • [1] Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances-Part 2: Particle number and size
    Lindberg, Jake
    Vitillo, Nicole
    Wurth, Marilyn
    Frank, Brian P.
    Tang, Shida
    LaDuke, Gil
    Fritz, Patricia Mason
    Trojanowski, Rebecca
    Butcher, Thomas
    Mahajan, Devinder
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2022, 72 (07) : 762 - 776
  • [2] Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances-Part 3: Optical properties of black and brown carbon emissions
    Lindberg, Jake
    Wurth, Marilyn
    Frank, Brian P.
    Tang, Shida
    LaDuke, Gil
    Trojanowski, Rebecca
    Butcher, Thomas
    Mahajan, Devinder
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2022, 72 (07) : 777 - 790
  • [3] Characterization of in-stack particulate emissions from residential wood hydronic heater appliances under different combustion conditions
    Lindberg, Jake
    Vitillo, Nicole
    Wurth, Marilyn
    Frank, Brian P.
    Tang, Shida
    LaDuke, Gil
    Fritz, Patricia Mason
    Trojanowski, Rebecca
    Butcher, Thomas
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2022, 72 (07) : 720 - 737
  • [4] Comparison of Emissions from Wood Combustion. Part 1: Emission Factors and Characteristics from Different Small-Scale Residential Heating Appliances Considering Particulate Matter and Polycyclic Aromatic Hydrocarbon (PAH)-Related Toxicological Potential of Particle-Bound Organic Species
    Orasche, Juergen
    Seidel, Torben
    Hartmann, Hans
    Schnelle-Kreis, Juergen
    Chow, Judith C.
    Ruppert, Hans
    Zimmermann, Ralf
    [J]. ENERGY & FUELS, 2012, 26 (11) : 6695 - 6704