Isotope ratio analysis of carbon and nitrogen by elemental analyser continuous flow isotope ratio mass spectrometry (EA-CF-IRMS) without the use of a reference gas

被引:6
|
作者
Bay, L. J. [1 ]
Chan, S. H. [2 ]
Walczyk, T. [1 ,3 ]
机构
[1] Natl Univ Singapore, Dept Chem, Fac Sci, Singapore 119077, Singapore
[2] Hlth Sci Author, Food Safety Div, Appl Sci Grp, Singapore 169078, Singapore
[3] Natl Univ Singapore, Dept Biochem, Yong Loo Lin Sch Med, Singapore 119077, Singapore
关键词
D O I
10.1039/c4ja00284a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach to normalize measured isotope ratios (carbon and nitrogen) by elemental analyser continuous flow isotope ratio mass spectrometry (EA-CF-IRMS) was evaluated. Isotope ratios of samples are altered during the IRMS measurement and must be corrected for both instrumental drifts as well as instrumental isotope fractionation for comparing data within and between laboratories. Traditionally, the isotope ratio of a reference gas is measured intermittently to correct for time dependent changes in isotope fractionation over the course of the measurement. However, this step appears to be redundant as bracketing standards are usually included in a measurement run for comparisons between measurements and laboratories and they can serve, in principle, the same purpose. Here we show that measurements without normalization to the reference gas are on a par in terms of accuracy and precision with those where the reference gas was used when employing an optimized strategy for bracketing samples with reference standards. Abolishment of intermittent reference gas measurements in EA-CF-IRMS analysis has the potential to cut short the analysis time significantly, can help to save costs in commercial IRMS laboratories and may open a new door for instrument developers to design high through-put IRMS instruments.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [1] Preliminary study to characterize plastic polymers using elemental analyser/isotope ratio mass spectrometry (EA/IRMS)
    Berto, Daniela
    Rampazzo, Federico
    Gion, Claudia
    Noventa, Seta
    Ronchi, Francesca
    Traldi, Umberto
    Giorgi, Giordano
    Cicero, Anna Maria
    Giovanardi, Otello
    [J]. CHEMOSPHERE, 2017, 176 : 47 - 56
  • [2] A closer look into the nitrogen blank in elemental analyser/isotope ratio mass spectrometry measurements
    Langel, Reinhard
    Dyckmans, Jens
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 2051 - 2055
  • [3] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench Ⅱ
    刘运德
    周爱国
    甘义群
    刘存富
    余婷婷
    李小倩
    [J]. Journal of Central South University, 2013, 20 (01) : 193 - 198
  • [4] CF-IRMS (CONTINUOUS FLOW-ISOTOPE RATIO MASS-SPECTROMETRY), AN ANALYTICAL STABLE-ISOTOPE METHOD FOR BIOLOGICAL SAMPLES
    WAGNER, G
    [J]. ISOTOPENPRAXIS, 1992, 28 (01): : 114 - 115
  • [5] Deuterium/hydrogen isotope ratio measurement of water and organic samples by continuous-flow isotope ratio mass spectrometry using chromium as the reducing agent in an elemental analyser
    Kelly, SD
    Heaton, KD
    Brereton, P
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (15) : 1283 - 1286
  • [6] Forensic Analysis of Explosives Using Isotope Ratio Mass Spectrometry (IRMS)-Part 1: Instrument Validation of the DELTAplusXP IRMS for Bulk Nitrogen Isotope Ratio Measurements
    Benson, Sarah J.
    Lennard, Christopher J.
    Hill, David M.
    Maynard, Philip
    Roux, Claude
    [J]. JOURNAL OF FORENSIC SCIENCES, 2010, 55 (01) : 193 - 204
  • [7] Bias estimation in the certification of steroid reference materials for carbon isotope delta measurements via elemental analyser and gas chromatography-combustion-isotope ratio mass spectrometry
    Merrick, Jeffrey P.
    Liu, Fong-Ha
    Lewin, Mark
    Iavetz, Raluca
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (10)
  • [8] Oxygen isotope analysis of silicates using continuous flow isotope ratio mass spectrometry
    Kingston, A. W.
    Weis, D.
    Francois, R.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A474 - A474
  • [9] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench II
    Yun-de Liu
    Ai-guo Zhou
    Yi-qun Gan
    Cun-fu Liu
    Ting-ting Yu
    Xiao-qian Li
    [J]. Journal of Central South University, 2013, 20 : 193 - 198
  • [10] Evaluation of honey authenticity in Thailand by analysis of carbon stable isotope ratio using elemental analyser coupled to isotope ratio mass spectrometry and cavity ring-down spectrometry
    Kamdee, Kiattipong
    Naksuriyawong, Sasiwimon
    Uapoonphol, Nichtima
    Fungklin, Ratchai
    Esor, Jeerawat
    Permnamtip, Vorapot
    Meepho, Sang-arun
    Judprasong, Kunchit
    [J]. INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2023, 58 (05): : 2458 - 2464