A numerical and experimental study on the energy efficiency of a regenerative Heat and Mass Exchanger utilizing the counter-flow Maisotsenko cycle

被引:67
|
作者
Abadi, Ali Mohammad Ez [1 ]
Sadi, Meisam [1 ]
Farzaneh-Gord, Mahmood [2 ]
Ahmadi, Mohammad Hossein [3 ]
Kumar, Ravinder [4 ]
Chau, Kwok-wing [5 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, Shahrood Branch, Shahrood, Iran
[2] Ferdowsi Univ Mashhad, Fac Engn, Mech Engn Dept, Mashhad, Razavi Khorasan, Iran
[3] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[4] Lovely Profess Univ, Sch Mech Engn, Phagwara, India
[5] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
counter-flow configuration; heat and mass transfer modeling; Maisotsenko cycle; regenerative evaporative cooling; number of channels; POLLUTANT TRANSPORT MODEL; THERMAL COMFORT; SYSTEMS; STORAGE; EXERGY;
D O I
10.1080/19942060.2019.1617193
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, a numerical and experimental study is performed to evaluate the affecting variables on energy efficiency of a novel regenerative evaporative cooler utilizing dew-point indirect evaporative cooling. For first time, an investigation is experimentally and numerically carried out to study the effects of the channel number on important parameters such as product temperature and humidity ratio. Investigations are carried out for five configurations with various channel numbers. The comparison of the numerical and experimental results is obtained and well accuracy observed. For the five studied configurations, the results show that with an increase in the number of channels, the outlet temperature decreases. For an inlet air flow rate of 100?600?m(3)/h, the cooled outlet flow temperature changes to the range of 23.4?30.7?C, 19.7?28.3?C, 18?26.4?C, 17.2?25?C and 16.6?23.8?C. For the configurations with finned channels, the percentage of increase in produced air temperature reaches 11.5% for HMX B, 18.6% for HMX C, 23.4% for HMX D and 26.9% for HMX E, as compared with HMX A.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] PARAMETRIC INVESTIGATION OF A COUNTER-FLOW HEAT AND MASS EXCHANGER BASED ON MAISOTSENKO CYCLE
    Ali, Muzaffar
    Sheikh, Nadeem Ahmed
    Khalid, Omar
    Manzoor, Shehryar
    Ali, Hafiz Muhammad
    [J]. THERMAL SCIENCE, 2018, 22 (06): : 3099 - 3106
  • [2] Numerical study of the Maisotsenko cycle heat and mass exchanger
    Anisimov, Sergey
    Pandelidis, Demis
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 75 : 75 - 96
  • [3] Maisotsenko Cycle based Counter and Cross Flow Heat and Mass Exchanger: A Computational Study
    Tariq, Rasikh
    Sheikh, Nadeem Ahmed
    [J]. 2017 INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE), 2017, : 44 - 49
  • [4] Experimental and Numerical Design and Optimization of a Counter-Flow Heat Exchanger
    Bahrami, Salman
    Rahimian, Mohammad Hassan
    [J]. 2017 ASIA CONFERENCE ON MECHANICAL AND AEROSPACE ENGINEERING (ACMAE 2017), 2018, 151
  • [5] Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling
    Zhao, X.
    Li, J. M.
    Riffat, S. B.
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1942 - 1951
  • [6] Design and experimental analysis of counter-flow heat and mass exchanger incorporating (M-cycle) for evaporative cooling
    Khalid, Omar
    Butt, Zubair
    Tanveer, Waqas
    Rao, Hasan Iqbal
    [J]. HEAT AND MASS TRANSFER, 2017, 53 (04) : 1391 - 1403
  • [7] Numerical analysis of heat transfer of a nanofluid counter-flow heat exchanger
    Ozenbiner, Omer
    Yurddas, Ali
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 137
  • [8] Design and experimental analysis of counter-flow heat and mass exchanger incorporating (M-cycle) for evaporative cooling
    Omar Khalid
    Zubair Butt
    Waqas Tanveer
    Hasan Iqbal Rao
    [J]. Heat and Mass Transfer, 2017, 53 : 1391 - 1403
  • [9] Numerical analysis of a desiccant system with cross-flow Maisotsenko cycle heat and mass exchanger
    Pandelidis, Demis
    Anisimov, Sergey
    Worek, William M.
    Drag, Pawel
    [J]. ENERGY AND BUILDINGS, 2016, 123 : 136 - 150
  • [10] Comparison study of the counter-flow regenerative evaporative heat exchangers with numerical methods
    Pandelidis, Demis
    Anisimov, Sergey
    Worek, William M.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 84 : 211 - 224