Simultaneous Determination of Catechol and Hydroquinone on Nano-Co/L-Cysteine Modified Glassy Carbon Electrode

被引:3
|
作者
Huang, Baomei [1 ]
Yao, Chengwei [2 ]
Wang, Enyang [1 ]
Du, Shizhang [1 ]
Yang, Jing [1 ]
Lu, Xiaoquan [3 ]
机构
[1] MianYang Normal Univ, Coll Chem & Chem Engn, Mianyang 621000, Sichuan, Peoples R China
[2] China Aerodynam Res & Dev Ctr, Facil Design & Instrumentat Inst, Mianyang 621000, Sichuan, Peoples R China
[3] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
关键词
Catechol; Hydroquinone; Nano; cobalt; L-Cysteine; Electrochemical method; REDUCED GRAPHENE OXIDE; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC SENSOR; MESOPOROUS CARBON; PASTE ELECTRODE; DOPED GRAPHENE; POROUS CARBON; NANOCOMPOSITE; DERIVATIVES; NANOTUBES;
D O I
10.1002/elan.202100047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel and highly sensitive electrochemical method for simultaneous determination of catechol (CC) and hydroquinone (HQ) was developed, which worked at GCE modified with Nano cobalt (Nano-Co) by electrodeposition and L-Cysteine by electrochemical polymerization. The Nano-Co/L-Cysteine GCE was investigated by cyclic voltammetry (CV), SEM and EIS. The excellent conditions have been selected including supporting electrolyte, pH, accumulation time and scan rate. The calibration curves of were obtained that the linear regression equation was I=0.0734c+6x10(-6) in the range of 5.8 mu M to 103 mu M (R-2=0.9942) for CC and the linear regression equation was I=0.0566c+5x10(-6) in the range of 5.8 mu M to 100 mu M (R-2=0.9967) for HQ. The obtained detection limits of CC and HQ both were 6x10(-7) M. The modified electrode was successfully applied to the simultaneous determination of CC and HQ in water samples.
引用
收藏
页码:405 / 414
页数:10
相关论文
共 50 条
  • [1] Simultaneous determination of catechol and hydroquinone with L-cysteine and nickel cobaltite Co-Functionalised Graphene Oxide Modified Glassy Carbon Electrode
    Xue, Shan
    Wang, Kaiqian
    Cheng, Yalin
    Tu, Biyang
    Xia, Yang
    Yuan, Shengjie
    Tao, Haisheng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (04) : 899 - 914
  • [2] Simultaneous determination of hydroquinone and catechol using a glassy carbon electrode modified with gold nanoparticles, ZnS/NiS@ZnS quantum dots and L-cysteine
    Yong Wang
    Jianhang Qu
    Shufang Li
    Ying Dong
    Jianying Qu
    Microchimica Acta, 2015, 182 : 2277 - 2283
  • [3] Simultaneous determination of hydroquinone and catechol using a glassy carbon electrode modified with gold nanoparticles, ZnS/NiS@ZnS quantum dots and L-cysteine
    Wang, Yong
    Qu, Jianhang
    Li, Shufang
    Dong, Ying
    Qu, Jianying
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2277 - 2283
  • [4] Simultaneous Detection of Catechol and Hydroquinone by Gold Nanorods/Poly(L-cysteine) Modified Electrode
    Zhang, Keying
    Cheng, Deshun
    Yang, Lei
    Zhang, Ziqiang
    Li, Xiaoling
    Zhang, Na
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7860 - 7867
  • [5] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [6] Simultaneous Determination of Hydroquinone and Catechol at an Activated Glassy Carbon Electrode
    Ahammad, A. J. Saleh
    Sarker, Subrata
    Rahman, Md Aminur
    Lee, Jae-Joon
    ELECTROANALYSIS, 2010, 22 (06) : 694 - 700
  • [7] Electrocatalytic oxidation and simultaneous determination of catechol and hydroquinone at a novel carbon nano-fragment modified glassy carbon electrode
    Zhang, Chuyi
    Zeng, Lixuan
    Zhu, Xiaohua
    Yu, Chumei
    Zuo, Xiaoxi
    Xiao, Xin
    Nan, Junmin
    ANALYTICAL METHODS, 2013, 5 (09) : 2203 - 2208
  • [8] Simultaneous Determination of Catechol and Hydroquinone Based on Fluorinated Graphite Modified Glassy Carbon Electrode
    Ma Zhen-Hua
    Wang Hui-Cai
    Yao Xiao-Xia
    Liu Ming-Qiang
    Ma Yu-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (12) : 1906 - 1912
  • [9] L-Cysteine/glycine composite film modified glassy carbon electrode as an enhanced sensing platform for catechol determination
    He, Jiahong
    Xing, Shaohua
    Qiu, Ri
    Song, Zhongrong
    Zhang, Shengtao
    ANALYTICAL METHODS, 2014, 6 (04) : 1210 - 1218
  • [10] An electrochemically aminated glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    Wang, Xiuyun
    Xi, Min
    Guo, Mengmeng
    Sheng, Fangmeng
    Xiao, Guang
    Wu, Shuo
    Uchiyama, Shunichi
    Matsuura, Hiroaki
    ANALYST, 2016, 141 (03) : 1077 - 1082