Spectral simulation methodology for calibration transfer of near-infrared spectra

被引:45
|
作者
Sulub, Yusuf
Small, Gary W.
机构
[1] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[2] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
关键词
simulation; near-infrared spectroscopy; calibration transfer; partial least squares; PLS; glucose;
D O I
10.1366/000370207780466280
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A spectrum simulation method is described for use in the development and transfer of multivariate calibration models from near-infrared spectra. By use of previously measured molar absorptivities and solvent displacement factors, synthetic calibration spectra are computed using only background spectra collected with the spectrometer for which a calibration model is desired. The resulting synthetic calibration set is used with partial least squares regression to form the calibration model. This methodology is demonstrated for use in the analysis of physiological levels of glucose (1-30 mM) in an aqueous matrix containing variable levels of alanine, ascorbate, lactate, urea, and triacetin. Experimentally measured data from two different Fourier transform spectrometers with different noise levels and stabilities are used to evaluate the simulation method. With the more stable instrument (A), well-performing calibration models are obtained, producing a standard error of prediction (SEP) of 0.70 mM. With the less stable instrument (B), the calibration based solely on synthetic spectra is less successful, producing an SEP value of 1.58 mM. For cases in which the synthetic spectra do not describe enough spectral variance, an augmentation protocol is evaluated in which the synthetic calibration spectra are augmented with the spectra of a small number of experimentally measured calibration samples. For instruments A and B, respectively, augmentation with measured spectra of nine samples lowers the SEP values to 0.64 and 0.85 mM.
引用
收藏
页码:406 / 413
页数:8
相关论文
共 50 条
  • [1] Near-infrared calibration transfer based on spectral regression
    Peng, Jiangtao
    Peng, Silong
    Jiang, An
    Tan, Jie
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (04) : 1315 - 1320
  • [2] Spectral Encoder to Extract the Features of Near-Infrared Spectra for Multivariate Calibration
    Duan, Chaoshu
    Liu, Xuyang
    Cai, Wensheng
    Shao, Xueguang
    [J]. JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2022, 62 (16) : 3695 - 3703
  • [3] Wavelength calibration of near-infrared spectra
    Hinkle, KH
    Joyce, RR
    Hedden, A
    Wallace, L
    Engleman, R
    [J]. PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2001, 113 (783) : 548 - 566
  • [4] Calibration transfer of near-infrared spectra based on compression of wavelet coefficients
    Yoon, JG
    Lee, BW
    Han, CH
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2002, 64 (01) : 1 - 14
  • [5] A New Study of Calibration Model Transfer Method for Near-Infrared Spectral Analysis
    Liang Chen
    Zhao Zhong
    Cao Yu-ting
    Yuan Hong-fu
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (05) : 1589 - 1596
  • [6] Calibration model transfer for near-infrared spectra based on canonical correlation analysis
    Fan, Wei
    Liang, Yizeng
    Yuan, Dalin
    Wang, Jiajun
    [J]. ANALYTICA CHIMICA ACTA, 2008, 623 (01) : 22 - 29
  • [7] A new multivariate calibration model transfer method of near-infrared spectral analysis
    Liang, Chen
    Yuan, Hong-fu
    Zhao, Zhong
    Song, Chun-feng
    Wang, Jia-jun
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2016, 153 : 51 - 57
  • [8] Transfer of calibration in near-infrared reflectance spectrometry
    Dreassi, E
    Ceramelli, G
    Perruccio, PL
    Corti, P
    [J]. ANALYST, 1998, 123 (06) : 1259 - 1264
  • [9] TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY
    FORINA, M
    DRAVA, G
    ARMANINO, C
    BOGGIA, R
    LANTERI, S
    LEARDI, R
    CORTI, P
    CONTI, P
    GIANGIACOMO, R
    GALLIENA, C
    BIGONI, R
    QUARTARI, I
    SERRA, C
    FERRI, D
    LEONI, O
    LAZZERI, L
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) : 189 - 203
  • [10] A dual model strategy to transfer multivariate calibration models for near-infrared spectral analysis
    Wang, Jiajun
    Li, Zhengfeng
    Wang, Yi
    Liu, Yan
    Cai, Wensheng
    Shao, Xueguang
    [J]. SPECTROSCOPY LETTERS, 2016, 49 (05) : 348 - 354