Monte-Carlo-Based Estimation of the X-ray Energy Spectrum for CT Artifact Reduction

被引:7
|
作者
Nazemi, Ehsan [1 ]
Six, Nathanael [1 ]
Iuso, Domenico [1 ]
De Samber, Bjorn [1 ]
Sijbers, Jan [1 ]
De Beenhouwer, Jan [1 ]
机构
[1] Univ Antwerp, Dept Phys, Imec Vis Lab, B-2610 Antwerp, Belgium
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 07期
关键词
X-ray energy spectrum; Expectation Maximization; Monte Carlo simulation; imaging system; FleXCT; SIMULATION;
D O I
10.3390/app11073145
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Beam hardening and scattering effects can seriously degrade image quality in polychromatic X-ray CT imaging. In recent years, polychromatic image reconstruction techniques and scatter estimation using Monte Carlo simulation have been developed to compensate for beam hardening and scattering CT artifacts, respectively. Both techniques require knowledge of the X-ray tube energy spectrum. In this work, Monte Carlo simulations were used to calculate the X-ray energy spectrum of FleXCT, a novel prototype industrial micro-CT scanner, enabling beam hardening and scatter reduction for CT experiments. Both source and detector were completely modeled by Monte Carlo simulation. In order to validate the energy spectra obtained via Monte Carlo simulation, they were compared with energy spectra obtained via a second method. Here, energy spectra were calculated from empirical measurements using a step wedge sample, in combination with the Maximum Likelihood Expectation Maximization (MLEM) method. Good correlation was achieved between both approaches, confirming the correct modeling of the FleXCT system by Monte Carlo simulation. After validation of the modeled FleXCT system through comparing the X-ray spectra for different tube voltages inside the detector, we calculated the X-ray spectrum of the FleXCT X-ray tube, independent of the flat panel detector response, which is a prerequisite for beam hardening and scattering CT artifacts.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] X-Ray CT Energy Spectrum Estimation Algorithm Based on Weighted TV Normalization
    Li Lei
    Wang Lin-yuan
    Xi Xiao-qi
    Han Yu
    Yan Bin
    Bao Shang-lian
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (07) : 2230 - 2236
  • [2] MR Image Based Approach for Metal Artifact Reduction in X-Ray CT
    Anderla, Andras
    Culibrk, Dubravko
    Delso, Gaspar
    Mirkovic, Milan
    [J]. SCIENTIFIC WORLD JOURNAL, 2013,
  • [3] A prior-based metal artifact reduction algorithm for x-ray CT
    Li, Ming
    Zheng, Jian
    Zhang, Tao
    Guan, Yihui
    Xu, Pin
    Sun, Mingshan
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (02) : 229 - 241
  • [4] Comparative Methods for Metal Artifact Reduction in x-ray CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [5] A hybrid metal artifact reduction algorithm for x-ray CT
    Zhang, Yanbo
    Yan, Hao
    Jia, Xun
    Yang, Jian
    Jiang, Steve B.
    Mou, Xuanqin
    [J]. MEDICAL PHYSICS, 2013, 40 (04)
  • [6] Metal Artifact Reduction in X-ray CT via Ray Profile Correction
    Ha, Sungsoo
    Mueller, Klaus
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [7] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [8] Monte Carlo based calculation of patient exposure in X-ray CT-examinations
    Schmidt, R.
    Wulff, J.
    Kaestner, B.
    Jany, D.
    Heverhagen, J. T.
    Fiebich, M.
    Zink, K.
    [J]. 4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2487 - 2490
  • [9] CLIMAR: classified linear interpolation based metal artifact reduction for severe metal artifact reduction in x-ray CT imaging
    Yoon, Huisu
    Lee, Kyoung-Yong
    Bechwati, Ibrahim
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [10] Fast iterative algorithm for metal artifact reduction in X-ray CT
    Wang, G
    Frei, T
    Vannier, MW
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (08) : 607 - 614