Twice-refocused stimulated echo diffusion imaging: Measuring diffusion time dependence at constant T1 weighting

被引:4
|
作者
Martin, Jan [1 ]
Endt, Sebastian [1 ,2 ]
Wetscherek, Andreas [3 ,4 ]
Kuder, Tristan Anselm [5 ]
Doerfler, Arnd [6 ]
Uder, Michael [1 ]
Hensel, Bernhard [7 ]
Laun, Frederik Bernd [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Univ Hosp Erlangen, Inst Radiol, Erlangen, Germany
[2] Tech Univ Munich, Dept Comp Sci, Garching, Germany
[3] Inst Canc Res, Joint Dept Phys, London, England
[4] Royal Marsden NHS Fdn Trust, London, England
[5] German Canc Res Ctr, Dept Med Phys Radiol, Heidelberg, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg, Univ Hosp Erlangen, Inst Neuroradiol, Erlangen, Germany
[7] Friedrich Alexander Univ Erlangen Nurnberg, Ctr Med Phys & Engn, Erlangen, Germany
关键词
diffusion time dependence; microstructure; pulse sequence design; stimulated echo; T-1; relaxation; WHITE-MATTER; IN-VIVO; WATER DIFFUSION; HUMAN BRAIN; NERVOUS-SYSTEM; SELF-DIFFUSION; MONTE-CARLO; GRADIENT; EXCHANGE; MODEL;
D O I
10.1002/mrm.28046
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Diffusion times longer than 50 ms are typically probed with stimulated-echo sequences. Varying the diffusion time in stimulated-echo sequences affects the T-1 weighting of subcompartments, complicating the analysis of diffusion time dependence. Although inversion recovery preparation could be used to change the T-1 weighting, it cannot ensure equal T-1 weighting at arbitrary mixing times. In this article, a sequence that ensures constant T-1 weighting over a wide range of diffusion times is presented. Methods The proposed sequence features 2 independent longitudinal storage periods: TM1 and TM2. Diffusion encoding is performed during TM1, effectively coupling the diffusion time and TM1. Equal T-1 weighting at arbitrary diffusion times is realized by keeping the total mixing time TM1 + TM2 constant. The sequence was compared with conventional stimulated-echo measurements of diffusion in a 2-compartment phantom consisting of distilled water and paraffinum perliquidum. Additionally, in vivo DTI of the brain was carried out for 8 healthy volunteers with diffusion times ranging from 50 to 500 ms. Results Diffusion time dependence of the axial and radial diffusivity was detected in the brain. Both sequences resulted in almost identical diffusivities in white matter. In regions containing partial volumes of gray and white matter, a dependency on T-1 weighting was observed. Conclusion In accordance with previous studies, little variance of T-1 values appeared to be present in healthy white matter. However, this is likely different in diseased tissue. Here, the proposed sequence can be effective in differentiating between diffusion time dependence and T-1 weighting effects.
引用
收藏
页码:1741 / 1749
页数:9
相关论文
共 50 条
  • [1] A fractional motion diffusion model for a twice-refocused spin-echo pulse sequence
    Karaman, M. Muge
    Zhou, Xiaohong Joe
    NMR IN BIOMEDICINE, 2018, 31 (11)
  • [2] Orthogonalizing Crusher and Diffusion-Encoding Gradients to Suppress Undesired Echo Pathways in the Twice-Refocused Spin Echo Diffusion Sequence
    Nagy, Zoltan
    Thomas, David L.
    Weiskopf, Nikolaus
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 506 - 515
  • [3] Comparison of Twice Refocused Spin Echo Versus Stimulated Echo Diffusion Tensor Imaging for Tracking Muscle Fibers
    Noehren, Brian
    Andersen, Anders
    Feiweier, Thorsten
    Damon, Bruce
    Hardy, Peter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 624 - 632
  • [4] Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
    Reese, TG
    Heid, O
    Weisskoff, RM
    Wedeen, VJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 177 - 182
  • [5] Anomalous Diffusion Measured by a Twice-Refocused Spin Echo Pulse Sequence: Analysis Using Fractional Order Calculus
    Gao, Qing
    Srinivasan, Girish
    Magin, Richard L.
    Zhou, Xiaohang Joe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1177 - 1183
  • [6] BOLD background gradient contributions in diffusion-weighted fMRI-comparison of spin-echo and twice-refocused spin-echo sequences
    Pampel, Andre
    Jochimsen, Thies H.
    Moeller, Harald E.
    NMR IN BIOMEDICINE, 2010, 23 (06) : 610 - 618
  • [7] Assessing the radiofrequency shielding effect of titanium mesh on diffusion-weighted imaging: a comparative study of the twice-refocused spin-echo and Stejs']jskal-Tanner sequences
    Imamura, Eizaburo
    Jomoto, Wataru
    Takatsu, Yasuo
    Enoki, Takuya
    Wakayama, Tsukasa
    Kotoura, Noriko
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1051 - 1057
  • [8] Dependence of gradient-echo and spin-echo BOLD fMRI at 4T on diffusion weighting
    Michelich, Charles R.
    Song, Allen W.
    MacFall, James R.
    NMR IN BIOMEDICINE, 2006, 19 (05) : 566 - 572
  • [9] Echo time dependence of observed T1 in the human lung
    Triphan, Simon M. F.
    Jobst, Bertram J.
    Breuer, Felix A.
    Wielpuetz, Mark O.
    Kauczor, Hans-Ulrich
    Biederer, Juergen
    Jakob, Peter M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (03) : 610 - 616
  • [10] SPIN DIFFUSION AND ORIENTATION DEPENDENCE OF DEUTERIUM T1 IN SOLIDS
    YE, C
    ECKMAN, R
    PINES, A
    JOURNAL OF MAGNETIC RESONANCE, 1983, 55 (02) : 334 - 337