Detailed assessment of fetal ventricular septal defect with 4D color Doppler ultrasound using spatio-temporal image correlation technology

被引:31
|
作者
Yagel, S [1 ]
Valsky, DV [1 ]
Messing, B [1 ]
机构
[1] Hadassah Univ Hosp, Dept Obstet & Gynaecol, Jerusalem, Israel
关键词
D O I
10.1002/uog.1804
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
[No abstract available]
引用
收藏
页码:97 / 98
页数:2
相关论文
共 50 条
  • [1] Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC)
    Chaoui, R
    Hoffmann, J
    Heling, KS
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (06) : 535 - 545
  • [2] Examination of the fetal heart by four-dimensional (4D) ultrasound with spatio-temporal image correlation (STIC)
    Gonçalves, LF
    Lee, W
    Espinoza, J
    Romero, R
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (03) : 336 - 348
  • [3] Novel application of 4D sonography with B-flow imaging and spatio-temporal image correlation (STIC) in the assessment of the anatomy of pulmonary arteries in fetuses with pulmonary atresia and ventricular septal defect
    Volpe, P.
    Campobasso, G.
    Stanziano, A.
    De Robertis, V.
    Di Paolo, S.
    Caruso, G.
    Volpe, N.
    Gentile, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (01) : 40 - 46
  • [4] Assessment of Quality of Fetal Heart Views by 3D/4D Ultrasonography Using Spatio-Temporal Image Correlation in the Second and Third Trimesters of Pregnancy
    Rocha, Luciane Alves
    Rolo, Liliam Cristine
    Bello Barros, Fernanda Silveira
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    Araujo Junior, Edward
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (06): : 1015 - 1021
  • [5] Assessment of left ventricular function by spatio-temporal image correlation in fetuses with fetal growth restriction
    Tao Ziyu
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (09): : 1240 - 1244
  • [6] Spatio-temporal image correlation rendering mode visualizes the specific location and surrounding structure of ventricular septal defect
    Liu, Jinyu
    Wang, Yueheng
    Zhao, Huilin
    Liu, Weiwei
    CLINICAL ANATOMY, 2019, 32 (03) : 408 - 420
  • [7] Fetal cardiac interventricular septum: volume assessment by 3D/4D ultrasound using spatio-temporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL)
    Rolo, Liliam Cristine
    Martins Santana, Eduardo Felix
    da Silva, Priscila Henriques
    Costa, Fabricio Da Silva
    Machado Nardozza, Luciano Marcondes
    Tonni, Gabriele
    Moron, Antonio Fernandes
    Araujo Junior, Edward
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2015, 28 (12): : 1388 - 1393
  • [8] Hemodynamic modeling of fetal aortic and ductal arches using computational fluid dynamics and 3D/4D spatio-temporal image correlation fetal echocardiography
    Chen, Z.
    He, Y. H.
    Li, S. L.
    Zhao, H. K.
    Liu, X. W.
    Ge, S. H. P.
    EUROPEAN HEART JOURNAL, 2016, 37 : 61 - 62
  • [9] Application of spatio-temporal image correlation technology in the diagnosis of fetal cardiac abnormalities
    He, Yihua
    Wang, Junlan
    Gu, Xiaoyan
    Zhang, Ye
    Han, Jiancheng
    Liu, Xiaowei
    Li, Zhian
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (06) : 1637 - 1642
  • [10] Robust Spatio-Temporal Registration of 4D Cardiac Ultrasound Sequences
    Bersveldsen, Jorn
    Toews, Matthew
    Danudibroto, Adriyana
    Wells, William M., III
    Urheim, Stig
    Estepar, Raul San Jose
    Samset, Eigil
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790