Photon beam energy dependent single-arc volumetric modulated arc optimization

被引:1
|
作者
Momin, Shadab [1 ,2 ]
Grafe, James L. [2 ]
Georgiou, Konstantinos [3 ]
Khan, Rao F. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63130 USA
[2] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[3] Ryerson Univ, Dept Math, Toronto, ON, Canada
关键词
Single arc VMAT; Multiple photon energy optimization; Convex relaxation; IMRT; RADIATION-THERAPY; INTENSITY; IMRT;
D O I
10.1016/j.ejmp.2021.02.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths. & nbsp; Methods and materials: Owing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD). Results: The contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP?VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP?VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP?VMAT either improved or maintained femoral heads compared to SE?VMAT. SAMP?VMAT reduced the nontarget tissue integral dose in all ten cases. Conclusions: A single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage.
引用
下载
收藏
页码:122 / 133
页数:12
相关论文
共 50 条
  • [1] On Formulation of a Single-rotation Volumetric Modulated Arc Therapy with Simultaneous Optimization of Photon Beam Energy
    Momin, Shadab
    Grafe, James
    Khan, Rao
    MEDICAL PHYSICS, 2019, 46 (11) : 5396 - 5397
  • [2] Comparison of Single-Arc and Multiple-Arc Approaches for Delivering of Volumetric Modulated Arc Therapy
    Cao, D.
    Afghan, M.
    Ye, J.
    Wong, T.
    Shepard, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Single-Arc Volumetric Modulated Arc Therapy Planning for Left Breast Cancer and Regional Nodes
    Sakumi, Akira
    Shiraishi, Kenshiro
    Onoe, Tsuyoshi
    Yamamoto, Kentaro
    Haga, Akihiro
    Yoda, Kiyoshi
    Ohtomo, Kuni
    Nakagawa, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (01) : 151 - 153
  • [4] Simultaneous optimization of mixed photon energy beams in volumetric modulated arc therapy
    Momin, Shadab
    Grafe, James
    Georgiou, Konstantinos
    Khan, Rao
    MEDICAL PHYSICS, 2019, 46 (09) : 3844 - 3863
  • [5] Dosimetric comparison of single-arc/partial-arc volumetric modulated arc therapy and intensity-modulated radiotherapy for peripheral and central lung cancer
    Akcay, Melek
    Etiz, Durmus
    Duruer, Kerem
    Bozdogan, Ozge
    Ozen, Alaattin
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 80 - 87
  • [6] Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique
    Chow, James C. L.
    Jiang, Runqing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 3 - 12
  • [7] Arc-modulated radiation therapy (AMRT): a single-arc form of intensity-modulated arc therapy
    Wang, Chao
    Luan, Shuang
    Tang, Grace
    Chen, Danny Z.
    Earl, Matt A.
    Yu, Cedric X.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (22): : 6291 - 6303
  • [8] Simultaneous Optimization of Dual Energy for Volumetric Modulated Arc Therapy
    Momin, S.
    Grafe, J.
    Khan, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E178 - E179
  • [9] Dosimetric Impact of Breathing Cycle Irregularity On Target Dose for Pancreatic Cancer Using Single-Arc Volumetric Modulated Arc Therapy
    Nakamura, M.
    Goto, Y.
    Ishihara, V.
    Mukutnoto, N.
    Kishi, T.
    Mizowaki, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [10] Single-Arc IMRT?
    Bortfeld, Thomas
    Webb, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01): : N9 - N20