The use of a hand-held conductivity meter for the diagnosis of subclinical mastitis in dairy cows during late lactation

被引:5
|
作者
Mansell, PD [1 ]
Seguya, A [1 ]
机构
[1] Univ Melbourne, Werribee, Vic 3030, Australia
关键词
conductivity; mastitis; diagnosis; dairy; cattle; cow;
D O I
10.1080/00480169.2003.36325
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
AIM: To evaluate the accuracy of a hand-held electrical conductivity meter for the detection of subclinical mastitis in an Australian dairy herd in late lactation. METHODS: A hand-held conductivity meter was evaluated during late lactation in a herd of dairy cows that had a high prevalence of Streptococcus agalactiae and Staphylococcus aureus infection. The ability of the conductivity meter to accurately discriminate between uninfected quarters and those infected with major pathogens was assessed, using bacteriology as the definitive test for infection status. Milk samples for bacteriology, and electrical conductivity measurements; were collected from 233 quarters from 59 cows. The ability of the device to identify infected and uninfected cows was also assessed. Sensitivity and specificity were calculated for a range of threshold values, using absolute values, the range of quarter values within a cow and the ratio of quarter values within a cow. RESULTS: Electrical conductivity was higher in infected quarters than uninfected quarters, but the degree of overlap between the populations was substantial, even when quarters were assessed as case-control pairs from the same cow. Use of the device according to the manufacturer's recommendations for diagnostic criteria of mastitic quarters had a sensitivity of 51% and a specificity of 71%. The ability of the device to correctly diagnose the infection status of cows was dependent on both the analytical method and the threshold value used. Applying the manufacturer's recommended criteria to the diagnosis of the status of cows, the sensitivity of the test was 91% and the specificity 17%. CONCLUSION: The variability between individual quarters and between cows in this study was such that the use of this device to measure the conductivity of milk was not a reliable method by which to diagnose subclinical mastitis in cows in late lactation. CLINICAL RELEVANCE: Interpretation of results from handheld conductivity meters when used for the diagnosis of subclinical mastitis in dairy cows needs to be made with care. In some circumstances the results obtained do not accurately reflect the bacteriological status of either individual quarters, or cows.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [1] Use of a hand-held meter for detecting subclinical ketosis in dairy cows
    Voyvoda, Huseyin
    Erdogan, Hasan
    [J]. RESEARCH IN VETERINARY SCIENCE, 2010, 89 (03) : 344 - 351
  • [2] IDENTIFICATION OF SUBCLINICAL MASTITIS WITH A HAND-HELD ELECTRICAL-CONDUCTIVITY METER
    HILLERTON, JE
    WALTON, AW
    [J]. VETERINARY RECORD, 1991, 128 (22) : 513 - 515
  • [3] An evaluation of a hand-held electrical resistance meter for the diagnosis of bovine subclinical mastitis in late lactation under Australian conditions
    Seguya, AG
    Mansell, PD
    [J]. AUSTRALIAN VETERINARY JOURNAL, 2000, 78 (09) : 608 - 611
  • [4] Evaluation of a hand-held electrical conductivity meter for detection of subclinical mastitis in cattle
    Musser, JMB
    Anderson, KL
    Caballero, M
    Amaya, D
    Maroto-Puga, J
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 1998, 59 (09) : 1087 - 1091
  • [5] Sensitivity and specificity of a hand-held milk electrical conductivity meter compared to the California mastitis test for mastitis in dairy cattle
    Fosgate, G. T.
    Petzer, I. M.
    Karzis, J.
    [J]. VETERINARY JOURNAL, 2013, 196 (01): : 98 - 102
  • [6] Assessment of the economic relevance of the treatment of subclinical mastitis during lactation in dairy cows
    Seegers, H
    Billon, D
    Fourichon, C
    Hortet, P
    [J]. 9TH MEETING ON RUMINANT RESEARCH, 2002, : 29 - 32
  • [7] Evaluation of hand-held sodium, potassium, calcium, and electrical conductivity meters for diagnosing subclinical mastitis and intramammary infection in dairy cattle
    Kandeel, Sahar A.
    Megahed, Ameer A.
    Constable, Peter D.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2019, 33 (05) : 2343 - 2353
  • [8] USE OF A CONDUCTIVITY METER FOR THE DETECTION OF SUBCLINICAL MASTITIS
    CHAMINGS, RJ
    MURRAY, G
    BOOTH, JM
    [J]. VETERINARY RECORD, 1984, 114 (10) : 243 - 245
  • [9] Use of serum amyloid A and milk amyloid A in the diagnosis of subclinical mastitis in dairy cows
    Gerardi, Gabriele
    Bernardini, Daniele
    Elia, Carla Azzurra
    Ferrari, Vanni
    Iob, Luciano
    Segato, Severino
    [J]. JOURNAL OF DAIRY RESEARCH, 2009, 76 (04) : 411 - 417
  • [10] Evaluation of the hand-held Precision Xtra system for diagnosing ketosis in early lactation dairy cows.
    Oetzel, G. R.
    [J]. JOURNAL OF DAIRY SCIENCE, 2010, 93 : 526 - 526