Direct vertebral rotation significantly decreases the pullout strength of the pedicle screw: a biomechanical study in adult cadavers

被引:5
|
作者
Sariyilmaz, Kerim [1 ]
Ozkunt, Okan [2 ]
Gemalmaz, Halil Can [1 ]
Cingoz, Tunca [1 ]
Pehlivanoglu, Tuna [3 ]
Aksoy, Tamer [4 ]
Kaya, Ozcan [2 ]
Baydogan, Murat [5 ]
Dikici, Fatih [1 ]
机构
[1] Acibadem Mehmet Ali Aydinlar Univ, Dept Orthoped & Traumatol, Sch Med, Turgut Ozal Bulvari 16, TR-34303 Istanbul, Turkey
[2] Istinye Univ, Dept Orthoped & Traumatol, Liv Bahcesehir Hosp, Istanbul, Turkey
[3] Istanbul Educ & Res Hosp, Dept Orthoped & Traumatol, Minist Hlth, Istanbul, Turkey
[4] Hlth Sci Univ, Istanbul Training & Res Hosp, Dept Nucl Med, Istanbul, Turkey
[5] Istanbul Tech Univ, Dept Met, Istanbul, Turkey
来源
关键词
biomechanical; cadaveric vertebra; direct vertebral rotation; pedicle screw; pullout strength; ADOLESCENT IDIOPATHIC SCOLIOSIS; COTREL-DUBOUSSET INSTRUMENTATION; FIXATION; DEROTATION; IMPACT; HOOKS; SPINE;
D O I
10.1097/BPB.0000000000000751
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The pullout strength of the pedicle screws after direct vertebral rotation (DVR) maneuver is not known. This biomechanical study was performed to quantitatively analyze the pullout strength of a pedicle screw after DVR maneuver using human cadaveric vertebrae. Thoracic vertebral bodies from three cadavers were harvested and stripped of soft tissues. Thirty pedicles of 15 vertebrae were separated into two groups after bone mineral density measurements. Polyaxial 5.5 mm pedicle screws with appropriate length were inserted with a freehand technique for each pedicle. One Kirschner wire was inserted to the anterior part of each vertebral corpus the half depth of each corpus was embedded into PVC pipes using polyester paste. In the DVR group, each screw was pulled horizontally with 2 kg (similar to 20 N) load over a screwdriver rigidly attached to the screw, and a DVR maneuver was simulated. The control group did not load with a DVR maneuver. Samples were placed on a universal testing machine and pullout loads were measured. The Mann-Whitney U test was utilized, and the P value <0.05 was considered as statistically significant. In the DVR group, the mean pullout strength was 183.35 N (SD +/- 100.12), and in the control group, the mean pullout strength was 279.95 N (SD +/- 76.26). Intergroup comparisons revealed that DVR maneuver significantly decreases the pullout strength (P = 0.012). The results of this study confirm that the pullout strength of pedicle screw significantly decreases by approximately 35% when DVR maneuver is applied.
引用
收藏
页码:230 / 234
页数:5
相关论文
共 44 条
  • [1] Biomechanical analysis of pedicle screw pullout strength
    Bianco, R-J.
    Arnoux, P-J.
    Mac-Thiong, J-M.
    Wagnac, E.
    Aubin, C-E.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 246 - 248
  • [2] DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH
    Pinheiro, Romulo Pedroza
    Zamarioli, Ariane
    Chandanson, Thibault
    George, Keri
    Shimano, Antonio Carlos
    Defino, Helton Luiz Aparecido
    ACTA ORTOPEDICA BRASILEIRA, 2021, 29 (04): : 203 - 206
  • [3] Biomechanical Pullout Strength and Stability of the Cervical Artificial Pedicle Screw
    Barnes, Alison H.
    Eguizabal, Johnny A.
    Acosta, Frank L., Jr.
    Lotz, Jeffrey C.
    Buckley, Jenni M.
    Ames, Christopher P.
    SPINE, 2009, 34 (01) : E16 - E20
  • [4] Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study
    Kim, Young-Yul
    Choi, Woo-Sung
    Rhyu, Kee-Won
    SPINE JOURNAL, 2012, 12 (02): : 164 - 168
  • [5] Biomechanical study on pullout strength of thoracic extrapedicular screw fixation
    付长峰
    刘一
    张绍昆
    宋之明
    Chinese Journal of Traumatology, 2006, (06) : 374 - 376
  • [6] Biomechanical study on pullout strength of thoracic extrapedicular screw fixation
    付长峰
    刘一
    张绍昆
    宋之明
    中华创伤杂志(英文版), 2006, (06) : 374 - 376
  • [7] Strength of Thoracic Spine under Simulated Direct Vertebral Rotation: A Biomechanical Study
    Borkowski S.L.
    Sangiorgio S.N.
    Bowen R.E.
    Scaduto A.A.
    He B.
    Bauer K.L.
    Ebramzadeh E.
    Spine Deformity, 2016, 4 (2) : 85 - 93
  • [8] BIOMECHANICAL STUDY OF PEDICLE SCREW FIXATION STRENGTH: ASSOCIATION OF SCREW MALPOSITION AND SCREW INSERTION TORQUE
    Tsai, Tsung-Ting
    Chen, Yu-Hung
    Liao, Chao-Yaug
    Lin, Hsin-Tzu
    Liu, Mu-Yi
    Chen, Jin-Kai
    Lai, Po-Liang
    Tai, Ching-Lung
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (02)
  • [9] Biomechanical Investigation of a Novel Revision Device in an Osteoporotic Model Pullout Strength of Pedicle Screw Anchor Versus Larger Screw Diameter
    Manon, Jacinto
    Hussain, Mir M.
    Harris, Jonathan
    Moldavsky, Mark
    La Marca, Frank
    Bucklen, Brandon S.
    CLINICAL SPINE SURGERY, 2017, 30 (06): : 265 - 271
  • [10] Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    Barber, JW
    Boden, SD
    Ganey, T
    Hutton, WC
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (03): : 215 - 220