A power series expansion method based on frequency response function matrix for sensitivity analysis of viscously damped system

被引:0
|
作者
Shen, Jingfang
Diao, Yuxian [1 ]
机构
[1] Huazhong Agr Univ, Dept Sci, Wuhan 430070, Hubei, Peoples R China
关键词
MODE SHAPE SENSITIVITIES; EIGENVECTOR DERIVATIVES; NATURAL FREQUENCY; EIGENVALUES; EIGENSOLUTIONS; EFFICIENT; DISTINCT;
D O I
10.1088/1755-1315/94/1/012007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The modal method represents the derivative of the eigenvector as a superposition of all modes. Although this method is relatively effective, it has a problem of modal truncation error. In this paper, based on the two kinds of calculation methods of frequency response function matrix, the transformation relationship between system matrices and eigensolutions is proposed. Meanwhile the transition from the high-order modes to the low-order modes is emphasized. Then the conversion relationship is applied to reduce the modal truncation error, and finally a more accurate method for sensitivity analysis is derived.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Design sensitivity analysis for transient response of non-viscously damped systems based on direct differentiate method
    Ding, Zhe
    Li, Li
    Zou, Guangming
    Kong, Jianyi
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 121 : 322 - 342
  • [2] Hybrid expansion method for frequency responses and their sensitivities, Part II: Viscously damped systems
    Qu, ZQ
    Selvam, RP
    [J]. JOURNAL OF SOUND AND VIBRATION, 2000, 238 (03) : 369 - 388
  • [3] A comparative study of design sensitivity analysis based on adjoint variable method for transient response of non-viscously damped systems
    Ding, Zhe
    Li, Li
    Li, Xiaobai
    Kong, Jianyi
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 110 : 390 - 411
  • [4] Design sensitivity analysis for transient response of non-viscously damped dynamic systems
    Kyeong-Soo Yun
    Sung-Kie Youn
    [J]. Structural and Multidisciplinary Optimization, 2017, 55 : 2197 - 2210
  • [5] Design sensitivity analysis for transient response of non-viscously damped dynamic systems
    Yun, Kyeong-Soo
    Youn, Sung-Kie
    [J]. STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2017, 55 (06) : 2197 - 2210
  • [6] A new sensitivity analysis method of frequency response function
    Hua, HX
    Shi, YM
    Qu, ZQ
    [J]. IMAC - PROCEEDINGS OF THE 17TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I AND II, 1999, 3727 : 1869 - 1872
  • [7] Operational Modal Analysis Method Based on the Pseudo Frequency Response Function Matrix
    Chen, Tao
    Chu, Zhigang
    Li, Peiran
    Peng, Chuan
    Yang, Liang
    [J]. Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (20): : 266 - 276
  • [8] An improved series expansion method of frequency response function under medium and high frequency excitations
    Ning, Wei
    Wang, Jun
    Zhang, Jing-Hui
    [J]. INTERNATIONAL JOURNAL OF MECHANICS AND MATERIALS IN DESIGN, 2010, 6 (01) : 11 - 15
  • [9] An improved series expansion method of frequency response function under medium and high frequency excitations
    Wei Ning
    Jun Wang
    Jing-Hui Zhang
    [J]. International Journal of Mechanics and Materials in Design, 2010, 6 : 11 - 15
  • [10] Nonparametric identification method for frequency response function of a lightly damped multi-variable system
    Zhou, Yi
    Zhang, Erliang
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (19): : 182 - 186