In view of the abnormal tripping of a circuit breaker in 220 kv substation, according to the protection action, field inspection and test, the author preliminarily determines that the reason of the fault is the abnormal operation of the mechanical transmission mechanism of the circuit breaker. For the fault, it is put forward that the same type of circuit breaker and the same batch of mechanical transmission mechanism should he completely replaced, and B maintenance for this type of circuit breaker with longer operating life should be carried out to prevent similar faults from happening again.
引用
收藏
页码:210 / 213
页数:4
相关论文
共 50 条
  • [1] Fault Analysis of 220kV High Voltage Circuit Breaker
    Yan, Lin
    Wang, Wei
    [J]. 2019 6TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2019), 2019, : 737 - 741
  • [2] Main Transformer Fault Analysis in 220kV Substation
    Wu, Dong-xun
    Wang, Miao
    Liu, Ji-wu
    [J]. PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 551 - 554
  • [3] Analysis of Abnormal Discharge of 220kV Transformer
    Liu Hong
    Liang Jizhong
    Wang Wei
    Guo Ruizhou
    [J]. PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 2388 - 2392
  • [4] Calculation of Base Price of 220kV Circuit Breaker in the Background of "Battalion Reform"
    Ren, Chumeng
    [J]. 2016 2ND INTERNATIONAL CONFERENCE ON BUSINESS AND FINANCE (BF 2016), 2016, 4 : 77 - 80
  • [5] Discuss the Solution to Hydraulic Gear Secondary Circuit Hidden Danger on the 220KV Circuit Breaker
    Xu Yao-hui
    Duan Li-wei
    Du Shi-min
    Chen Zong-yan
    [J]. 12TH ANNUAL MEETING OF CHINA ASSOCIATION FOR SCIENCE AND TECHNOLOGY ON INFORMATION AND COMMUNICATION TECHNOLOGY AND SMART GRID, 2010, : 105 - 107
  • [6] Failure analysis of phase B pull rod of HGIS circuit breaker operating mechanism in 220 kV Substation
    Lyu, Lei
    Chen, Hao
    Zhang, Yanfei
    Bai, Haolun
    [J]. Journal of Physics: Conference Series, 2021, 1885 (04):
  • [7] The Analysis of 220kV Transformer Abnormal DC Resistance
    Lan Wei
    Cheng Pengfei
    Wang Qinghao
    Liu Chenyang
    Zhang Hua
    Liu Bo
    Li Bo
    Liu Chuanbo
    Wu Yunguo
    Huang Zijun
    Dong Pin
    Liu Zhaohui
    Gao Wei
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 2031 - 2034
  • [8] Research on Improving 220kV Bus Short Circuit Current Level of 500kV Substation
    Wang, Kui
    Yan, Dawei
    Li, Hui
    Wang, Xuejun
    Li, Yuanyuan
    Luo, Tao
    Lei, Zheng
    Cui, Guangsheng
    Zhou, Jin
    Liu, Lixia
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1706 - 1710
  • [9] Research on Continuous Lightning Strokes Analysis and Protection of 220kV Substation
    Zhao, Xiaofeng
    Liao, Zhiming
    Li, Qian
    Yang, Lei
    Li, Zhaoting
    Han, Yongxia
    Yang, Xian
    [J]. 2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 955 - 963
  • [10] Process Level Network Performance Analysis in 220kV Smart Substation
    Jiang, Jiandong
    Gong, Xiangyu
    Wei, Renran
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 4220 - 4224