Multicentre dose audit for clinical trials of radiation therapy in Asia

被引:2
|
作者
Mizuno, Hideyuki [1 ]
Fukuda, Shigekazu [1 ]
Fukumura, Akifumi [1 ]
Nakamura, Yuzuru-Kutsutani [1 ]
Cao Jianping [2 ]
Cho, Chul-Koo [3 ]
Supriana, Nana [4 ]
Dung, To Anh [5 ]
Calaguas, Miriam Joy [6 ]
Devi, C. R. Beena [7 ]
Chansilpa, Yaowalak [8 ]
Banu, Parvin Akhter [9 ]
Riaz, Masooma [10 ]
Esentayeva, Surya [11 ]
Kato, Shingo [12 ]
Karasawa, Kumiko [13 ]
Tsujii, Hirohiko [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol QST, Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Soochow Univ, Suzhou, Peoples R China
[3] Korea Inst Radiol & Med Sci, Seoul, South Korea
[4] Cipto Mangunkusumo Hosp, Jakarta, Indonesia
[5] Natl Canc Hosp, Hanoi, Vietnam
[6] St Lukes Med Ctr, Quezon City, Philippines
[7] Sarawak Gen Hosp, Kuching, Sarawak, Malaysia
[8] Mahidol Univ, Siriraj Hosp, Bangkok, Thailand
[9] Delta Hosp Ltd, Dhaka, Bangladesh
[10] Inst Nucl Med & Oncol, Lahore, Pakistan
[11] Kazakh Res Inst Oncol & Radiol, Alma Ata, Kazakhstan
[12] Saitama Med Univ, Int Med Ctr, Moroyama, Saitama, Japan
[13] Tokyo Womens Med Univ Hosp, Tokyo, Japan
关键词
dosimetry; dose audit; linac; forum for nuclear cooperation in Asia; radiophotoluminescent glass dosimeter; NUCLEAR COOPERATION; CERVICAL-CANCER; NASOPHARYNGEAL CANCER; RADIOTHERAPY; FORUM; DOSIMETER; EAST;
D O I
10.1093/jrr/rrw108
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of +/- 5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy.
引用
收藏
页码:372 / 377
页数:6
相关论文
共 50 条
  • [1] Multicentre dose audit for clinical trials of radiation therapy in Asia
    Mizuno, Hideyuki
    Fukuda, Shigekazu
    Fukumura, Akifumi
    Nakamura, Yuzuru-Kutsutani
    Jianping, Cao
    Cho, Chul-Koo
    Supriana, Nana
    Dung, To Anh
    Calaguas, Miriam Joy
    Devi, C.R. Beena
    Chansilpa, Yaowalak
    Banu, Parvin Akhter
    Riaz, Masooma
    Esentayeva, Surya
    Kato, Shingo
    Karasawa, Kumiko
    Tsujii, Hirohiko
    Journal of Radiation Research, 2017, 58 (03): : 372 - 377
  • [2] The need for multicentre cardiovascular clinical trials in Asia
    Joey S. W. Kwong
    Cheuk-Man Yu
    Nature Reviews Cardiology, 2013, 10 : 355 - 362
  • [3] The need for multicentre cardiovascular clinical trials in Asia
    Kwong, Joey S. W.
    Yu, Cheuk-Man
    NATURE REVIEWS CARDIOLOGY, 2013, 10 (06) : 355 - 362
  • [4] Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials
    Prezado, Y.
    Fois, G.
    Edouard, M.
    Nemoz, C.
    Renier, M.
    Requardt, H.
    Esteve, F.
    Adam, J. F.
    Elleaume, H.
    Bravin, A.
    MEDICAL PHYSICS, 2009, 36 (03) : 725 - 733
  • [5] Multicentre quality assurance of intensity-modulated radiation therapy plans: A precursor to clinical trials
    Williams, M. J.
    Bailey, M. J.
    Forstner, D.
    Metcalfe, P. E.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (05): : 472 - 479
  • [6] External dosimetry audit for quality assurance of carbon-ion radiation therapy clinical trials
    Mizuno, Hideyuki
    Fukumura, Akifumi
    Kanematsu, Nobuyuki
    Yonai, Shunsuke
    Shirai, Toshiyuki
    Yusa, Ken
    Yanou, Toshihiro
    Suga, Masaki
    Mizota, Manabu
    Minohara, Shinichi
    Kanai, Tatsuaki
    Kamada, Tadashi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 31 - 36
  • [7] Dose Specification for NRG Radiation Therapy Trials
    Gladstone, David J.
    Kry, Stephen F.
    Xiao, Ying
    Chetty, Indrin J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (05): : 1344 - 1345
  • [8] IMPROVING ANAEMIA THERAPY IN HAEMODIALYSIS PATIENTS: RESULTS OF A MULTICENTRE CLINICAL AUDIT
    Macdougall, Iain C.
    Sousa, Antonio
    Andrade, Carlos
    Schumann, Erika
    Ryzlewicz, Thomas
    Becker, Franz-Ferdinand
    Fairburn-Beech, Amelia
    Kilgallon, William
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 277 - 277
  • [9] Multicentre clinical trials
    Garattini, S
    Bertele, V
    LANCET, 1999, 353 (9156): : 930 - 930
  • [10] A virtual audit system for intensity-modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials
    Nakamura, Mitsuhiro
    RADIOTHERAPY AND ONCOLOGY, 2024, 197 : S27 - S28