Derating of distribution transformers for non-sinusoidal load currents using finite element method

被引:0
|
作者
Faiz, J [1 ]
Sharifian, MBB
Fakheri, SA
Sabet-Marzooghi, E
机构
[1] Univ Tehran, Dept Elect & Comp Engn, Tehran, Iran
[2] Univ Tabriz, Dept Elect Engn, Tabriz, Iran
[3] Tabriz Elect Power Distribut Co, Tabriz, Iran
来源
关键词
transformer; nonlinear load; finite element method;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transformers are normally designed and built for use at rated frequency and prefect sinusoidal load current. Non-linear loads on a transformed lead to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these problems, the rated capacity of a transformer, which supply non-linear loads must be reduced. In this paper a 50-kVA three-phase distribution transformer is modeled using the finite element (FE) method and its losses are estimated under rated frequency and load conditions, as well as under non-linear loads. An equivalent rating of the transformer is estimated based on the harmonic loss factor and is compared to the recomended standard rating. This comparison shows that the estimation of derating of the transformer supplying non-linear loads rising the standard recommendations is acceptable, but slightly conservative.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [1] Derating of distribution transformers for non-sinusoidal load currents using finite element method
    Sharifian, MBB
    Faiz, J
    Fakheri, SA
    Zraatparvar, A
    [J]. ICECS 2003: PROCEEDINGS OF THE 2003 10TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2003, : 754 - 757
  • [2] Derating of transformers under non-sinusoidal loads
    Sadati, S. B.
    Tahani, A.
    Jafari, M.
    Dargahi, M.
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL I, 2008, : 263 - 268
  • [3] Derating of transformers under non-linear load current and non-sinusoidal voltage - an overview
    Faiz, Jawad
    Ghazizadeh, Milad
    Oraee, Hashem
    [J]. IET ELECTRIC POWER APPLICATIONS, 2015, 9 (07) : 486 - 495
  • [4] Impacts of Non-Sinusoidal Load Currents on Distribution Transformer Losses-Part I: Theoretical Aspects and Finite Element Based Simulation
    Mirzaie, M.
    Yazdani-Asrami, M.
    Sadati, S. B.
    Akmal, A. Shayegani
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (05): : 2207 - 2214
  • [5] Losses Distribution in Sheathed Power Cables Under Non-Sinusoidal Currents Using Numerical Method
    Rasoulpoor, Masoumeh
    Mirzaie, Mohammad
    Mirimani, Seyyed Mehdi
    [J]. COMPUTER APPLICATIONS IN ENGINEERING EDUCATION, 2016, 24 (05) : 692 - 705
  • [6] Transformer Assessment Practices Under Non-Sinusoidal Load Currents
    Fragozo Diaz, Rafael Enrique
    Malagon Carvajal, Gabriel Alexis
    Chacon Velasco, Julio Cesar
    Ordonez Plata, Gabriel
    Giraldo Picon, Wilson
    [J]. INGE CUC, 2014, 10 (01) : 63 - 74
  • [7] Winding Position in Power Transformers to Reduce Copper Losses: Non-sinusoidal Currents
    Cougo, Bernardo
    Meynard, Thierry
    Forest, Francois
    Laboure, Eric
    [J]. 2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 3959 - +
  • [8] DANGER CAUSED BY NON-SINUSOIDAL CURRENTS
    EGYPTIEN, HH
    [J]. ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1977, 29 (01): : 15 - 15
  • [9] Calculation of losses and ampacity derating in medium-voltage cables under harmonic load currents using finite element method
    Rasoulpoor, Masoumeh
    Mirzaie, Mohammad
    Mirimani, Seyyed Mehdi
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2017, 27 (03):
  • [10] Evaluating and Derating of Three-Phase Distribution Transformer under Unbalanced Voltage and Unbalance Load Using Finite Element Method
    Njafi, Atabak
    Iskender, Ires
    Genc, Naci
    [J]. 2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 160 - 165