Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using microfluidic paper-based analytical devices

被引:0
|
作者
Kamnoet, Pornphimon [1 ]
Aeungmaitrepirom, Wanlapa [1 ]
Menger, Ruth F. [2 ]
Henry, Charles S. [2 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, Environm Anal Res Unit EARU, Phayathai Rd, Bangkok 10330, Thailand
[2] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
SOLID-PHASE EXTRACTION; HEAVY-METAL IONS; COLORIMETRIC DETERMINATION; SENSOR; COPPER; QUANTIFICATION; AGGREGATION; MEMBRANE; LIQUID; WAX;
D O I
10.1039/d0an02200d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new paper-based analytical device design was fabricated by a wax printing method for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii). Colorimetry was used to quantify these heavy metal ions using bathocuproine (Bc), dimethylglyoxime (DMG), dithizone (DTZ), and 4-(2-pyridylazo) resorcinol (PAR) as complexing agents. The affinity of complexing agents to heavy metal ions is dependent on the formation constant (K-f). To enhance the selectivity for heavy metal ion determination, the new device was designed with two pretreatment zones, where masking agents remove the interfering ions. It was found that two pretreatment zones worked better than a single pretreatment zone at removing interferences. The reaction time, sample and complexing agent volumes, and complexing agent concentrations were optimized. The analytical results were achieved with the lowest detectable concentrations of 0.32, 0.59, 5.87, 0.20, and 0.11 mg L-1 for Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii), respectively. The linear ranges were found to be 0.32-63.55 mg L-1 (Cu(ii)), 0.59-4.71 mg L-1 (Co(ii)), 5.87-352.16 mg L-1 (Ni(ii)), 0.20-12.04 mg L-1 (Hg(ii)), and 0.11-0.55 mg L-1 (Mn(ii)). The lowest detectable concentration and linearity for the five metal ions allow the application of this device for the determination of heavy metal ions in various water samples. The sensor showed high selectivity and efficiency for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in drinking, tap, and pond water samples on a single device and detection with the naked eye. The results illustrated that the proposed sensor showed good accuracy and precision agreement with the standard ICP-OES method.
引用
收藏
页码:2229 / 2239
页数:11
相关论文
共 50 条
  • [1] Quantum-dot-functionalized paper-based device for simultaneous visual detection of Cu(II), Mn(II), and Hg(II)
    Yue, Jinping
    Lv, Qing
    Wang, Wan
    Zhang, Qing
    [J]. TALANTA OPEN, 2022, 5
  • [2] INTERACTION OF MN(II), CO(II), NI(II), CU(II), ZN(II), CD(II) AND HG(II) WITH BIURET
    SRIVASTAVA, PC
    BANERJEE, BK
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1979, 17 (06): : 583 - 585
  • [3] Paper-based microfluidics for experimental design: screening masking agents for simultaneous determination of Mn(II) and Co(II)
    Meredith, Nathan A.
    Volckens, John
    Henry, Charles S.
    [J]. ANALYTICAL METHODS, 2017, 9 (03) : 534 - 540
  • [4] Construction and Application of an Electrochemical Sensor for Simultaneous Determination of Cd( II), Cu( II) and Hg( II) in Water and Foodstuff Samples
    Afkhami, Abbas
    Moosavi, Razieh
    Madrakian, Tayyebeh
    Keypour, Hassan
    Ramezani-Aktij, Ameneh
    Mirzaei-Monsef, Misagh
    [J]. ELECTROANALYSIS, 2014, 26 (04) : 786 - 795
  • [5] SUCCINIMIDE COMPLEXES OF CU(II), NI(II), CO(II), FE(II) AND HG(II)
    SHARMA, CL
    SHARMA, S
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1976, 14 (07): : 534 - 535
  • [6] Simultaneous determination of Zn(II), Cd(II) and Hg(II) in water
    Raimundo, IM
    Narayanaswamy, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 90 (1-3) : 189 - 197
  • [7] A prototype microfluidic paper-based chromatic device for simultaneous determination of copper(II) and zinc(II) in urine
    Perez-Rodriguez, Michael
    del Pilar Canizares-Macias, Maria
    [J]. TALANTA OPEN, 2023, 7
  • [8] STUDIES ON THIOCYANATE AND CYANATE COMPLEXES OF MN(II), FE(II), CO(II), NI(II), CU(II), ZN(II), CD(II), HG(II) AND PD(II)
    SINGH, PP
    KHAN, SA
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1976, 14 (03): : 176 - 178
  • [9] Complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), and Hg(II) with ON-NO donor chelating tetradentate ligands
    Mahapatra, BB
    Mishra, ASP
    [J]. ASIAN JOURNAL OF CHEMISTRY, 1998, 10 (03) : 610 - 612
  • [10] PERIODATE AS AN ANALYTICAL REAGENT .4. ESTIMATION OF THIOCYANATE AND ITS APPLICATION IN DETERMINATION OF CU(II), ZN(II), CD(II), CO(II), NI(II) AND HG(II)
    KAUSHIK, RL
    PROSAD, R
    [J]. INDIAN JOURNAL OF CHEMISTRY, 1970, 8 (11): : 1034 - &