Multiple Pinhole Collimator Based Microscopic X-ray Luminescence Computed Tomography

被引:0
|
作者
Zhang, Wei [1 ]
Zhu, Dianwen [1 ]
Li, Changqing [1 ]
机构
[1] Univ Calif Merced, Sch Engn, Merced, CA 95343 USA
关键词
X-ray Luminescence; Multiple Pinholes Collimator; Tomography; FLUORESCENCE MOLECULAR TOMOGRAPHY; OPTICAL TOMOGRAPHY;
D O I
10.1117/12.2213751
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray luminescence computed tomography (XLCT) is a new hybrid imaging modality, which has the capability to improve optical spatial resolution to hundreds of micrometers for deep targets. In this paper, we report a multiple pinhole collimator based microscopic X-ray luminescence computed tomography (microXLCT) system for small animal imaging. Superfine collimated X-ray pencil beams are used to excite deeply embedded phosphor particles, allowing us to obtain sub-millimeter optical spatial resolution in deep tissues. Multiple collimated X-ray beams are generated by mounting an array of pinholes in the front of a powerful X-ray tube. With multiple X-ray beams scanning, the phosphor particles in the region of the multiple beams are excited simultaneously, which requires less scanning time compared with a single beam scanning The emitted optical photons on the top surface of the phantom are measured with an electron multiplying charge-coupled device (EMCCD) camera. Meanwhile, an X-ray detector is used to determine the X-ray beam size and position, which are used as structural guidance in the microXLCT image reconstruction. To validate the performance of our proposed multiple pinhole based microXLCT imaging system, we have performed numerical simulations and a phantom experiment. In the numerical simulations, we simulated a cylindrical phantom with two and six embedded targets, respectively. In the simulations, we used four parallel X-ray beams with the beam diameter of 0.1 mm and the beam interval of 3.2 mm. We can reconstruct deeply embedded multiple targets with a target diameter of 0.2 mm using measurements in six projections, which indicated that four parallel X-ray beam scan could reduce scanning time without comprising the reconstructed image quality. In the phantom experiment, we generated two parallel X-ray beams with the beam diameter of 0.5 mm and the beam interval of 4.2 mm. We scanned a phantom of one target with the two parallel X-ray beams. The target was reconstructed successfully, which indicated that multiple collimated X-ray beam scan approach is feasible in small animal imaging.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multiple pinhole collimator based X-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Lun, Michael
    Li, Changqing
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (07): : 2506 - 2523
  • [2] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [3] Collimated superfine x-ray beam based x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Lun, Michael
    Li, Changqing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 945 - 957
  • [4] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [5] Multi-Pinhole Based X-Ray Fluorescence Computed Tomography: A Comparison with Single Pinhole Case
    Sasaya, Tenta
    Sunaguchi, Naoki
    Seo, Seung-Jun
    Zeniya, Tsutomu
    Hyodo, Kazuyuki
    Kim, Jong-Ki
    Yuasa, Tetsuya
    IMAGE AND SIGNAL PROCESSING (ICISP 2018), 2018, 10884 : 205 - 212
  • [6] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [7] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [9] Contrast agents for x-ray luminescence computed tomography
    Lun, Michael C.
    Ranasinghe, Meenakshi
    Arifuzzaman, Mohammad
    Fang, Yile
    Guo, Yiping
    Anker, Jeffrey N.
    Li, Changqing
    APPLIED OPTICS, 2021, 60 (23) : 6769 - 6775
  • [10] Fast X-Ray Luminescence Computed Tomography Imaging
    Liu, Xin
    Liao, Qimei
    Wang, Hongkai
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (06) : 1621 - 1627