Measurement of retention in comprehensive two-dimensional gas chromatography using flow modulation with methane dopant

被引:6
|
作者
Klee, Matthew S. [1 ]
Blumberg, Leonid M. [2 ]
机构
[1] Agilent Technol, Wilmington, DE 19808 USA
[2] Fast GC Consulting, Wilmington, DE 19801 USA
关键词
GC x GC; Flow modulation; Hold-up time; Temperature-programmed GC; Elution retention factors; SEPARATIONS;
D O I
10.1016/j.chroma.2010.01.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow modulation of methane-doped carrier gas is used to visualize the second dimension hold-Lip time in CC x GC continuously throughout the run This provides an internal reference of hold-up time and presents a straight forward means of examining retention in each dimension of GC x GC Retention factors on similar and dissimilar column pairs are examined Stationary phase bleed is shown to be retained by the second dimension column. (C) 2010 Elseviei B V All rights reserved
引用
收藏
页码:1830 / 1837
页数:8
相关论文
共 50 条
  • [1] Pulsed flow modulation comprehensive two-dimensional gas chromatography
    Poliak, Marina
    Kochman, Maya
    Amirav, Aviv
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 189 - 195
  • [2] Comprehensive two-dimensional gas chromatography via differential flow modulation
    Seeley, JV
    Kramp, F
    Hicks, CJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (18) : 4346 - 4352
  • [3] Retention indices in comprehensive two-dimensional gas chromatography
    von Muehlen, Carin
    Marriott, Philip J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2351 - 2360
  • [4] Retention indices in comprehensive two-dimensional gas chromatography
    Carin von Mühlen
    Philip J. Marriott
    [J]. Analytical and Bioanalytical Chemistry, 2011, 401 : 2351 - 2360
  • [5] Retention modeling and retention time prediction in gas chromatography and flow-modulation comprehensive two-dimensional gas chromatography: The contribution of pressure on solute partition
    Burel, Antoine
    Vaccaro, Marie
    Cartigny, Yohann
    Tisse, Severine
    Coquerel, Gerard
    Cardinael, Pascal
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 : 101 - 119
  • [6] Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation - An intralaboratory study
    Shellie, RA
    Xie, LL
    Marriott, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 161 - 170
  • [7] Modulation ratio in comprehensive two-dimensional gas chromatography
    Khummueng, Weeraya
    Harynuk, James
    Marriott, Philip J.
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (13) : 4578 - 4587
  • [8] Comprehensive two-dimensional gas chromatography with pattern modulation
    Seeley, John V.
    Seeley, Stacy K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1421 : 114 - 122
  • [9] Evaluation of a retention model in comprehensive two-dimensional gas chromatography
    Vendeuvre, C
    Bertoncini, F
    Thiébaut, D
    Martin, M
    Hennion, MC
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1129 - 1136
  • [10] Retention correlation maps in comprehensive two-dimensional gas chromatography
    Western, RJ
    Marriott, PJ
    [J]. JOURNAL OF SEPARATION SCIENCE, 2002, 25 (13) : 832 - 838