Experimental investigations on the behaviour of autoclaved aerated concrete under fatigue and sustained loads

被引:0
|
作者
Raue, E [1 ]
Tartsch, E [1 ]
机构
[1] Bauhaus Univ Weimar, Dept Reinforced Concrete Struct, D-99421 Weimar, Germany
关键词
autoclaved aerated concrete; AAC; fatigue strength; sustained loading strength; sinusoidal loading; stiffness degradation; smith diagram; S/N plot;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fatigue strength of concrete is lower than static strength. It was tried to accelerate destabilisation process due to microcracking by fatigue loads in order to get information about it's sustained loading strength quickly. Fatigue strength of autoclaved aerated concrete (AAC) is observed applying cyclic loads to unreinforced cylinders. The AAC was found to be less sensitive than lightweight concrete to fatigue loads. The fatigue tests are supplemented by tests with sustained loads. It can be assumed that both the behaviour under static and fatigue loads is comparable with that of lightweight and normal concrete. A substantial influence of load duration especially at high load levels was found.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 50 条
  • [1] Experimental and Modeling Investigations on the Water Sorption Behaviors of Autoclaved Aerated Concrete
    Garbalinska, Halina
    Bochenek, Magdalena
    Stasiak, Marcin
    MATERIALS, 2021, 14 (21)
  • [2] Experimental Investigation of Autoclaved Aerated Concrete Masonry
    Bhosale, Avadhoot
    Zade, Nikhil P.
    Davis, Robin
    Sarkar, Pradip
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (07)
  • [3] Thermal behaviour of autoclaved aerated concrete exposed to fire
    Karim, Ghazi Wakili
    Hugi, E.
    Karvonen, L.
    Schnewlin, P.
    Winnefeld, F.
    CEMENT & CONCRETE COMPOSITES, 2015, 62 : 52 - 58
  • [4] Investigations of Forming Mixture Parameters of Autoclaved Aerated Concrete with Nanoadditives
    Lekunaite, Lina
    Laukaitis, Antanas
    Kligys, Modestas
    Mikulskis, Donatas
    MATERIALS SCIENCE-MEDZIAGOTYRA, 2012, 18 (03): : 284 - 289
  • [5] Microstructural investigations of naturally and artificially weathered autoclaved aerated concrete
    Kus, H
    Carlsson, T
    CEMENT AND CONCRETE RESEARCH, 2003, 33 (09) : 1423 - 1432
  • [6] Autoclaved aerated concrete behavior under explosive action
    Yankelevsky, DZ
    Avnon, I
    CONSTRUCTION AND BUILDING MATERIALS, 1998, 12 (6-7) : 359 - 364
  • [7] Experimental and numerical investigation of polymer-reinforced and normal autoclaved aerated concrete masonry walls under large TNT explosive loads
    Yu, Qi
    Zeng, Dan
    Xu, Xuan
    Li, Suling
    Dong, Wenxue
    Dai, Lan
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2022, 164
  • [9] Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling
    Ferretti, D.
    Michelini, E.
    Rosati, G.
    CEMENT AND CONCRETE RESEARCH, 2015, 67 : 156 - 167
  • [10] Experimental Investigation on Flexural Performance of Autoclaved Aerated Concrete Slab
    Zhang, Guo-Wei
    Chen, Bo-Shan
    Miao, Qi-Song
    Wu, Hui
    Chen, Peng
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHANICS AND CIVIL ENGINEERING, 2014, 7 : 1019 - +