Upgrade of the X-ray pinhole camera system at SSRF

被引:3
|
作者
Gao, Bo [1 ,2 ]
Leng, Yong-Bin [1 ,2 ]
Chen, Han-Jiao [1 ,2 ]
Chen, Jie [1 ]
Ye, Kai-Rong [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
美国国家科学基金会;
关键词
X-ray pinhole camera; Transverse beam size; Diagnostic beam line; Point spread function; X-ray quasimonochromator;
D O I
10.1007/s41365-018-0444-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since 2009. The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera. Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size. However, this calibration method requires special beam conditions. In order to overcome this limitation, the pinhole camera was upgraded and an X-ray quasi-monochromator was installed. A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function. The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size. The X-ray spectrum can also be obtained. In this work, the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Upgrade of the X-ray pinhole camera system at SSRF
    Bo Gao
    Yong-Bin Leng
    Han-Jiao Chen
    Jie Chen
    Kai-Rong Ye
    NuclearScienceandTechniques, 2018, 29 (08) : 9 - 17
  • [2] Upgrade of the X-ray pinhole camera system at SSRF
    Bo Gao
    Yong-Bin Leng
    Han-Jiao Chen
    Jie Chen
    Kai-Rong Ye
    Nuclear Science and Techniques, 2018, 29
  • [3] The beam-based calibration of an X-ray pinhole camera at SSRF
    冷用斌
    黄国庆
    张满洲
    陈之初
    陈杰
    叶恺容
    中国物理C, 2012, (01) : 80 - 83
  • [4] The beam-based calibration of an X-ray pinhole camera at SSRF
    Leng Yong-Bin
    Huang Guo-Qing
    Zhang Man-Zhou
    Chen Zhi-Chu
    Chen Jie
    Ye Kai-Rong
    CHINESE PHYSICS C, 2012, 36 (01) : 80 - 83
  • [5] TEMPORAL X-RAY ASTRONOMY WITH A PINHOLE CAMERA
    HOLT, SS
    ASTROPHYSICS AND SPACE SCIENCE, 1976, 42 (01) : 123 - 141
  • [6] Fluorescent X-ray imaging with pinhole camera
    Dudchik, Yu. I.
    Hilko, G. I.
    Lomashko, Yu. K.
    DEVICES AND METHODS OF MEASUREMENTS, 2016, 7 (02): : 169 - 175
  • [7] X-RAY PINHOLE CAMERA WITH NANOSECOND RESOLUTION
    BERNSTEIN, MJ
    HAI, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (12): : 1843 - +
  • [8] Los Alamos pinhole camera (LAPC): A new flexible x-ray pinhole camera
    Oertel, JA
    Peterson, CG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 786 - 788
  • [9] USE OF A CCD ARRAY IN AN X-RAY PINHOLE CAMERA
    CAVAILLER, C
    HENRY, P
    LAUNSPACH, J
    MENS, A
    ROSTAING, M
    SAUNEUF, R
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 442 - 450
  • [10] X-ray pinhole camera resolution and emittance measurement
    Thomas, Cyrille
    Rehm, Guenther
    Martin, Ian
    Bartolini, Riccardo
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2010, 13 (02):