Quantitative flow phantom for contrast-enhanced breast tomosynthesis

被引:3
|
作者
Nock, Melissa L. [1 ,2 ]
Kempston, Michael P. [1 ]
Mainprize, James G. [1 ]
Yaffe, Martin J. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, 2075 Bayview ave, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
radiographic phantom; tomosynthesis; digital mammography; breast angiography; iodine contrast agent; image quality;
D O I
10.1117/12.708549
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of contrast agents can help to overcome a lack of intrinsic radiographic contrast between malignant and benign breast tissue by taking advantage of the properties of tumour angiogenesis. Studies of contrast-enhanced mammography have demonstrated increased lesion conspicuity and have shown that this technique provides information on contrast uptake kinetics. It has been suggested that malignant and benign lesions can be differentiated in part by their uptake kinetics, so this additional data may lead to more accurate diagnoses. Tomosynthesis is a 3D x-ray imaging technique that permits lesion depth localization and increased conspicuity in comparison with 2D x-ray projection techniques. This modality, used in combination with contrast agents, promises to be a sensitive method of breast cancer detection. To develop the technique of contrast-enhanced breast tomosynthesis, a dynamic flow phantom has been constructed to provide the same types of imaging challenges anticipated, in the clinical setting. These challenges include a low-contrast tumour space, relevant temporal contrast agent uptake and washout profiles, and a need for quantitative analysis of enhancement levels. The design of a flow phantom will be presented that includes a dynamic tumour space, a background that masks the tumour space in images without contrast enhancement, and flow characteristics that simulate tumour contrast agent uptake and washout kinetics. The system is calibrated to relate signal to concentration of the contrast agent using a well plate filled with iodinated water. Iodine detectability in the flow phantom is evaluated in terms of the signal-difference-to-noise ratio for various tomosynthesis image acquisition parameters including number of acquired angular views, angular extent, and reconstruction voxel size.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] System Calibration for Quantitative Contrast-Enhanced Digital Breast Tomosynthesis (CEDBT)
    Hill, Melissa L.
    Mainprize, James G.
    Yaffe, Martin J.
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 645 - 653
  • [2] Optimization of contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Li, Jingjing
    Chen, Sara
    Conant, Emily
    Maidment, Andrew D. A.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 183 - 189
  • [3] Quantification of contrast-enhanced digital breast tomosynthesis
    Maidment, A. D. A.
    Carton, A. -K.
    Chen, S.
    Conant, E. F.
    Schnal, M.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 12 - 14
  • [4] Contrast-enhanced breast tomosynthesis: A feasibility study
    Wu, T
    Rafferty, E
    Moore, R
    Kopans, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1796 - 1796
  • [5] Quantification for contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Li, Jingjing
    Albert, Michael
    Chen, Sara
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [6] A new breast phantom suitable for digital mammography, contrast-enhanced digital mammography and digital breast tomosynthesis
    Zhang, Changsheng
    Fu, Jian
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):
  • [7] Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment Comparison of contrast-enhanced
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [8] Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis-Comparison to contrast-enhanced breast MRI
    Chou, Chen-Pin
    Lewin, John M.
    Chiang, Chia-Ling
    Hung, Bao-Hui
    Yang, Tsung-Lung
    Huang, Jer-Shyung
    Liao, Jia-Bin
    Pan, Huay-Ben
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2501 - 2508
  • [9] Dependence of Contrast-Enhanced Lesion Detection in Contrast-Enhanced Digital Breast Tomosynthesis on Imaging Chain Design
    Scaduto, David A.
    Hu, Yue-Houng
    Lu, Yihuan
    Huang, Hailiang
    Liu, Jingxuan
    Rinaldi, Kim
    Gindi, Gene
    Fisher, Paul R.
    Zhao, Wei
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 136 - 144
  • [10] Initial clinical experience with contrast-enhanced digital breast tomosynthesis
    Chen, Sara C.
    Carton, Ann-Katherine
    Albert, Michael
    Conant, Emily F.
    Schnall, Mitchell D.
    Maidment, Andrew D. A.
    [J]. ACADEMIC RADIOLOGY, 2007, 14 (02) : 229 - 238