Comparison of Intensities and Rest Periods for VO2max Verification Testing Procedures

被引:50
|
作者
Nolan, P. B. [1 ]
Beaven, M. L. [1 ]
Dalleck, L. [2 ]
机构
[1] Univ Auckland, Dept Sport & Exercise Sci, Auckland 1, New Zealand
[2] Western State Colorado Univ, Gunnison, CO 81231 USA
关键词
exercise test; exercise; oxygen consumption; physical fitness; MAXIMAL OXYGEN-UPTAKE; CARDIORESPIRATORY FITNESS; CONFIRM ATTAINMENT; PHYSICAL-ACTIVITY; EXERCISE; CRITERIA; RISK; MEN; PERFORMANCE; CAPACITY;
D O I
10.1055/s-0034-1367065
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
We sought to determine the incidence of 'true' VO(2)max confirmation with the verification procedure across different protocols. 12 active participants (men n = 6, women n = 6) performed in random order 4 different maximal graded exercises tests (GXT) and verification bout protocols on 4 separate days. Conditions for the rest period and verification bout intensity were: A - 105 % intensity, 20 min rest; B -105 % intensity, 60 min rest; C - 115 % intensity, 20 min rest; D - 115 % intensity, 60 min rest. VO(2)max confirmation (difference between peak VO2 GXT and verification trial < +/- 3 %) using the verification trial was 12/12 (100 %), 12/12 (100 %), 8/12 (66.70 %), and 7/12 (58.33 %) for protocols A, B, C, and D. There was a signifi cant (p < 0.05) effect of verification intensity on VO(2)max confirmation across all exercise test conditions (intensity effect within recovery 20 min (chi(2) (1) = 4.800,p < 0.05), intensity effect within recovery 60 min (chi(2) (1) = 6.316, p < 0.05)). No signifi cant effect was found for incidence of VO(2)max confirmation with different rest periods. We recommend the use of 105 % of the maximal GXT workload and 20 min rest periods when using verification trials to confirm VO(2)max in normally active populations.
引用
收藏
页码:1024 / 1029
页数:6
相关论文
共 50 条
  • [1] A COMPARISON OF 4 PROCEDURES FOR THE DETERMINATION OF VO2MAX
    KEREN, G
    MAGAZANIK, A
    EPSTEIN, Y
    [J]. ISRAEL JOURNAL OF MEDICAL SCIENCES, 1980, 16 (03): : 219 - 219
  • [2] Verification Testing to Confirm VO2max in a Hot Environment
    Pryor, J. Luke
    Leija, Robert Garcia
    Morales, Jacobo
    Potter, Adam W.
    Looney, David P.
    Pryor, Riana R.
    Hostler, David
    Cochrane-Snyman, Kristen C.
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2021, 53 (04) : 763 - 769
  • [3] Efficacy of constant load verification testing to confirm VO2max attainment
    Astorino, Todd A.
    DeRevere, Jamie
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (04) : 703 - 709
  • [4] VERIFICATION CRITERIA FOR THE DETERMINATION OF VO2MAX IN THE FIELD
    Sanchez-Otero, Tania
    Iglesias-Soler, Eliseo
    Boullosa, Daniel A.
    Tuimil, Jose L.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (12) : 3544 - 3551
  • [5] Verification testing to confirm VO2max attainment in persons with spinal cord injury
    Astorino, Todd A.
    Bediamol, Noelle
    Cotoia, Sarah
    Ines, Kenneth
    Koeu, Nicolas
    Menard, Natasha
    Nguyen, Brianna
    Olivo, Cassandra
    Phillips, Gabrielle
    Tirados, Ardreen
    Cruz, Gabriela Velasco
    [J]. JOURNAL OF SPINAL CORD MEDICINE, 2019, 42 (04): : 494 - 501
  • [6] A COMPARISON OF VARIOUS METHODS FOR THE DETERMINATION OF VO2MAX
    KEREN, G
    MAGAZANIK, A
    EPSTEIN, Y
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 45 (2-3): : 117 - 124
  • [7] Time limit and VO2 slow component at intensities corresponding to VO2max in swimmers
    Fernandes, RJ
    Cardoso, CS
    Soares, SM
    Ascensao, A
    Colaço, PJ
    Vilas-Boas, JP
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2003, 24 (08) : 576 - 581
  • [8] VO2MAX LIMITS
    BOOTH, FW
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (03) : 1299 - 1300
  • [9] Validity and reproducibility of VO2max testing in a respiration chamber
    Kleinloog, Jordi P. D.
    van Laar, Stephen P. G. A.
    Schoffelen, Paul F. M.
    Plasqui, Guy
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2021, 31 (06) : 1259 - 1267
  • [10] Emergence of the verification phase procedure for confirming 'true' VO2max
    Midgley, A. W.
    Carroll, S.
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2009, 19 (03) : 313 - 322