Diagnosis of carbonation induced corrosion initiation and progression in reinforced concrete structures using piezo-impedance transducers

被引:79
|
作者
Talakokula, V. [1 ,2 ]
Bhalla, S. [2 ]
Ball, R. J. [3 ]
Bowen, C. R. [4 ]
Pesce, G. L. [3 ]
Kurchania, R. [5 ]
Bhattacharjee, B. [2 ]
Gupta, A. [2 ]
Paine, K. [3 ]
机构
[1] ABES Engn Coll, Dept Civil Engn, Ghaziabad 201009, India
[2] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
[3] Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
[4] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
[5] MANIT, Dept Phys, Bhopal 462051, India
基金
英国工程与自然科学研究理事会;
关键词
SEM; Chloride; Corrosion; Carbonation; Reinforced concrete; Electro-mechanical impedance (EMI) technique; STEEL; SENSORS;
D O I
10.1016/j.sna.2016.02.033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In addition to chloride induced corrosion, the other commonly occurring type of rebar corrosion in reinforced concrete structures is that induced by the ingress of atmospheric carbon dioxide into concrete, commonly referred to as 'carbonation induced corrosion'. This paper presents a new approach for detecting the onset and quantifying the level of carbonation induced rebar corrosion, The approach is based on the changes in the mechanical impedance parameters acquired using the electro-mechanical coupling of a piezoelectric lead zirconate titanate (PZT) ceramic patch bonded to the surface of the rebar. The approach is non-destructive and is demonstrated though accelerated tests on reinforced concrete specimens subjected to controlled carbon dioxide exposure for a period spanning over 230 days. The equivalent stiffness parameter, extracted from the frequency response of the admittance signatures of the PZT patch, is found to increase with penetration of carbon dioxide inside the surface and the consequent carbonation, an observation that is correlated with phenolphthalein staining. After the onset of rebar corrosion, the equivalent stiffness parameter exhibited a reduction in magnitude over time, providing a clear indication of the occurrence of corrosion and the results are correlated with scanning electron microscope images and Raman spectroscopy measurements. The average rate of corrosion is determined using the equivalent mass parameter. The use of PZT ceramic transducers, therefore, provides an alternate and effective technique for diagnosis of carbonation induced rebar corrosion initiation and progression in reinforced concrete structures non-destructively. (C) 2016 The Authors. Published by Elsevier B.V.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 50 条
  • [1] Detection of chloride and carbonation induced corrosion in reinforced concrete structures using piezo sensors via electro-mechanical impedance technique
    Visalakshi, T.
    Bhalla, S.
    Gupta, A.
    [J]. CONCRETE SOLUTIONS: PROCEEDINGS OF CONCRETE SOLUTIONS, 5TH INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, 2014, : 597 - 602
  • [2] Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete
    Soh, CK
    Bhalla, S
    [J]. SMART MATERIALS AND STRUCTURES, 2005, 14 (04) : 671 - 684
  • [3] Structural identification and damage diagnosis using self-sensing piezo-impedance transducers
    Lim, Yee Yan
    Bhalla, Suresh
    Soh, Chee Kiong
    [J]. SMART MATERIALS AND STRUCTURES, 2006, 15 (04) : 987 - 995
  • [4] Monitoring Beam-Column Joint in Concrete Structures Using Piezo-Impedance Sensors
    Divsholi, Bahador Sabet
    Yang, Yaowen
    Bing, Li
    [J]. MULTI-FUNCTIONAL MATERIALS AND STRUCTURES II, PTS 1 AND 2, 2009, 79-82 : 59 - 62
  • [5] Carbonation and Corrosion Problems in Reinforced Concrete Structures
    Al Fuhaid, Abdulrahman Fahad
    Niaz, Akbar
    [J]. BUILDINGS, 2022, 12 (05)
  • [6] Carbonation-Induced and Chloride-Induced Corrosion in Reinforced Concrete Structures
    Zhou, Y.
    Gencturk, B.
    Willam, K.
    Attar, A.
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2015, 27 (09)
  • [7] Analysis of the parameters affecting probabilistic predictions of initiation time for carbonation-induced corrosion of reinforced concrete structures
    Lollini, F.
    Redaelli, E.
    Bertolini, L.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2012, 63 (12): : 1059 - 1068
  • [8] The influence of hydrophobic surface coatings on carbonation induced corrosion in reinforced concrete structures
    Schallock, B. M.
    Gastaldi, M.
    [J]. METALLURGIA ITALIANA, 2023, 114 (09): : 26 - 32
  • [9] Effect of corrosion inhibitors on the initiation of chloride-induced corrosion on reinforced concrete structures
    Ormellese, M.
    Bolzoni, F.
    Lazzari, L.
    Pedeferri, P.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2008, 59 (02): : 98 - 106
  • [10] Prognosis of low-strain fatigue induced damage in reinforced concrete structures using embedded piezo-transducers
    Bhalla, Suresh
    Kaur, Naveet