Calcium phosphate cement leakage after percutaneous vertebroplasty for osteoporotic vertebral fractures: risk factor analysis for cement leakage

被引:40
|
作者
Nakano, M
Hirano, N
Ishihara, H
Kawaguchi, Y
Matsuura, K
机构
[1] Toyama Rosai Hosp, Dept Orthopaed Surg, Toyama 9370042, Japan
[2] Toyama Med & Pharmaceut Univ, Fac Med, Toyama, Japan
关键词
osteoporosis; vertebral fracture; vertebroplasty; calcium phosphate cement; complication;
D O I
10.3171/spi.2005.2.1.0027
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The purpose of this study was to analyze the risk factors for leakage of calcium phosphate cement (CPC) after vertebroplasty for osteoporotic vertebral fractures and to determine whether the vertebral body (VB) leakage caused any changes in the therapeutic benefits. Methods. Between August 2000 and April 2002, the authors performed 65 CPC-assisted vertebroplasty procedures in 55 patients with thoracic or lumbar osteoporotic vertebral fractures. Back and low-back pain were evaluated using the visual analog scale and the duration of analgesic medication requirement. Factors related to CPC leakage and the postoperative outcome were analyzed. There was a small amount of VB CPC leakage in 23 cases. In 10 of 23 cases, leakage into the epidural space was found. Although VB CPC leakage was independently associated with high initial age, female sex, high bone mineral density (BMD), short injury-surgery interval, and injection via the unipedicular route in the logistic regression analysis, there was no factor associated with CPC leakage into the epidural space. Cement leakage into the epidural space reduced the immediate therapeutic effects on fracture-related pain (p = 0.0128). All patients in whom cement leaked into the epidural space had improved by the 2-week follow-up examination. Conclusions. Advanced initial age, female sex, high BMD, a short interval from injury to surgery, and injection via the unipedicular route may increase the incidence of CPC leakage. Cement leakage into the epidural space attenuated only the immediate therapeutic effects of CPC-assisted vertebroplasty.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors
    Nieuwenhuijse, Marc J.
    Van Erkel, Arian R.
    Dijkstra, Sander
    [J]. SPINE JOURNAL, 2011, 11 (09): : 839 - 848
  • [2] Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures
    Jie Ding
    Qiong Zhang
    Jianfei Zhu
    Weiwei Tao
    Qi Wu
    Lu Chen
    Pengwen Shi
    Haojie Zhang
    [J]. European Spine Journal, 2016, 25 : 3411 - 3417
  • [3] Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures
    Ding, Jie
    Zhang, Qiong
    Zhu, Jianfei
    Tao, Weiwei
    Wu, Qi
    Chen, Lu
    Shi, Pengwen
    Zhang, Haojie
    [J]. EUROPEAN SPINE JOURNAL, 2016, 25 (11) : 3411 - 3417
  • [4] Adjacent Intravertebral Cement Leakage During Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures
    Qin, De-an
    Song, Jie-fu
    Liang, Qing-yuan
    [J]. PAIN MEDICINE, 2021, 22 (06) : 1453 - 1455
  • [5] Impact of Cement Placement and Leakage in Osteoporotic Vertebral Compression Fractures Followed by Percutaneous Vertebroplasty
    Chen, Xiaobin
    Ren, Jixin
    Zhang, Jianzheng
    Li, Shaoguang
    Liu, Zhi
    [J]. CLINICAL SPINE SURGERY, 2016, 29 (07): : E365 - E370
  • [6] New Vertebral Fractures after Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures: A Clustered Analysis and the Relevance of Intradiskal Cement Leakage
    Nieuwenhuijse, Marc J.
    Putter, Hein
    van Erkel, Arian R.
    Dijkstra, P. D. Sander
    [J]. RADIOLOGY, 2013, 266 (03) : 862 - 870
  • [7] Thick cement usage in percutaneous vertebroplasty for malignant vertebral fractures at high risk for cement leakage
    Reyad, R. M.
    Ghobrial, H. Z.
    Hakim, S. M.
    Hashem, R. H.
    Elsaman, A.
    Shaaban, M. H.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2017, 98 (10) : 721 - 728
  • [8] Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures Analysis of Risk Factors
    Xie, Weixing
    Jin, Daxiang
    Ma, Hui
    Ding, Jinyong
    Xu, Jixi
    Zhang, Shuncong
    Liang, De
    [J]. CLINICAL SPINE SURGERY, 2016, 29 (04): : E171 - E176
  • [9] Cement Leakage in Percutaneous Vertebroplasty for Multiple Osteoporotic Vertebral Compression Fractures: A Prospective Cohort Study
    Tran Anh Tuan
    Tran Van Luong
    Pharr Manh Cuong
    Vu Long
    Huynh Quang Huy
    Nguyen Minh Duc
    [J]. ORTHOPEDIC RESEARCH AND REVIEWS, 2020, 12 : 105 - 111
  • [10] Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures
    Yeom, JS
    Kim, WJ
    Choy, WS
    Lee, CK
    Chang, BS
    Kang, JW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (01): : 83 - 89