Right Coronary Artery Flow Velocity and Volume Assessment With Spiral K-Space Sampled Breathhold Velocity-Encoded MRI at 3 Tesla: Accuracy and Reproducibility

被引:14
|
作者
Brandts, Anne [1 ]
Roes, Stijntje D. [1 ]
Doornbos, Joost [1 ]
Weiss, Robert G. [2 ,3 ]
de Roos, Albert [1 ]
Stuber, Matthias [2 ,3 ,4 ,5 ,6 ]
Westenberg, Jos J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
[4] Johns Hopkins Univ, Dept Elect & Comp Engn, Div MR Res, Baltimore, MD 21218 USA
[5] Univ Lausanne, Lausanne, Switzerland
[6] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
基金
美国国家卫生研究院;
关键词
accuracy; reproducibility; MRI; coronary flow velocity; PHASE-CONTRAST FLOW; SIGNAL-TO-NOISE; MAGNETIC-RESONANCE ANGIOGRAPHY; BLOOD-FLOW; QUANTIFICATION; VALIDATION; EXCITATION; RESOLUTION; VESSELS; RATIOS;
D O I
10.1002/jmri.22144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. Materials and Methods: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). Results: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. Conclusion: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
引用
收藏
页码:1215 / 1223
页数:9
相关论文
共 8 条
  • [1] Measurement of coronary flow response to cold pressor stress in asymptomatic women with cardiovascular risk factors using spiral velocity-encoded cine MRI at 3 Tesla
    Maroules, Christopher D.
    Chang, Alice Y.
    Kontak, Andrew
    Dimitrov, Ivan
    Kotys, Melanie
    Peshock, Ronald M.
    ACTA RADIOLOGICA, 2010, 51 (04) : 420 - 426
  • [2] Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames
    Clarke, GD
    Hundley, WG
    McColl, RW
    Eckels, R
    Smith, D
    Chaney, C
    Li, HF
    Peshock, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05): : 733 - 742
  • [3] Quantification of coronary artery volume flow rate using fast velocity-encoded cine MR imaging
    Sakuma, H
    Saeed, M
    Takeda, K
    Wendland, MF
    Schwitter, J
    Szolar, DH
    Derugin, N
    Shimakawa, A
    Foo, TKF
    Higgins, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1363 - 1367
  • [4] Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation
    Saito, Y
    Sakuma, H
    Shibata, M
    Okinaka, T
    Isaka, N
    Tomemori, T
    Takeda, K
    Nakano, T
    Higgins, CB
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (03) : 209 - 214
  • [5] Coronary sinus flow reserve in response to cold pressor stress in healthy women using velocity-encoded cine (VEC) spiral 3 T MRI
    Christopher D Maroules
    Alice Y Chang
    Andrew Kontak
    Hardik Yadav
    Tommy Tillery
    Ron M Peshock
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [6] Comparison of spiral and FLASH phase velocity mapping, with and without breath-holding, for the assessment of left and right coronary artery blood flow velocity
    Keegan, J
    Gatehouse, PD
    Mohiaddin, RH
    Yang, GZ
    Firmin, DN
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) : 40 - 49
  • [7] Leveling of arterial wall stiffness between aortic arch and left carotid artery due to aging is associated with reduced volume flow towards the brain: pulse wave velocity evaluation with high-field velocity-encoded MRI
    Eleanore Kroner
    Hildo J Lamb
    Pieter J van den Boogaard
    Hans-Marc J Siebelink
    Ernst E van der Wall
    Albert de Roos
    Jos J Westenberg
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [8] Clinical application of 3D velocity-encoded magnetic resonance imaging: a new tool for the assessment of tricuspid and pulmonary valve flow and diastolic function of the right ventricle in patients after correction of Tetralogy of Fallot
    Annelies E van der Hulst
    Jos JM Westenberg
    Lucia JM Kroft
    Jeroen J Bax
    Nico A Blom
    Albert de Roos
    Arno AW Roest
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)