Assessment of Interfacial Charge Accumulation in Oil-Paper Interface in Transformer Insulation from Polarization-Depolarization Current Measurements

被引:56
|
作者
Mishra, D. [1 ]
Haque, N. [2 ]
Baral, A. [1 ]
Chakravorti, S. [2 ,3 ]
机构
[1] Indian Sch Mines, Indian Inst Technol, Elect Engn Dept, Dhanbad 826004, Jharkhand, India
[2] Jadavpur Univ, Elect Engn Dept, Kolkata 700032, W Bengal, India
[3] Jadavpur Univ, Kolkata, India
关键词
Interfacial charge; polarization-de-polarization; current; oil-paper insulation; transformer; FREQUENCY-DOMAIN; SYSTEM; MODEL; TIME;
D O I
10.1109/TDEI.2017.006525
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accumulation of interfacial space charge in oil-paper interface is a critical issue in insulation diagnostics of transformers. This interfacial charge mainly accumulates due to the conductivity difference of oil and paper. Accumulation of interfacial charge leads to localized field enhancement, which further leads to partial discharges and acceleration in the aging of insulation. Therefore, from the point of view of transformer insulation diagnostics, assessment of interfacial charge is very important. However, it is not easy to estimate interfacial space charge behavior from the transformer diagnostics methods currently in use. In case of Polarization-Depolarization Current (PDC) measurement, a well known method for transformer condition monitoring, the effect of interfacial charge is reflected in the non-linearity of current response during polarization and de-polarization. During de-polarization process, a part of the interfacial charge accumulated during polarization period is absorbed by the electrodes producing a current, which is difficult to separate using conventional linear dielectric theory. In this paper, an attempt has been made to separate this current component from de-polarization current through considering charge de-trapping mechanism. Terming this current component as de-trapping current, its relationship with other parameters of transformer insulation is discussed. The developed methodology has been applied on several practical transformers. It was observed that the time constant of de-trapping current is related to the paper conductivity, oil conductivity, dissipation factor and age of the insulation.
引用
收藏
页码:1665 / 1673
页数:9
相关论文
共 50 条
  • [1] Correlation between Polarization-depolarization Current and Interface Barrier in Oil-paper Insulation
    Ma, Yun-tong
    Wu, Kai
    Lv, Ze-peng
    Peng, Jin-yang
    Zhang, Chen
    Wang, Bing-jie
    [J]. 2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 269 - 273
  • [2] Effect of Temperature on Condition Assessment of Oil-Paper Insulation using Polarization-Depolarization Current
    Saurabh
    Mukherjee, M.
    Pradhan, A. K.
    Baral, A.
    Chakravorti, S.
    [J]. 2016 NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2016,
  • [3] Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers
    Saha, TK
    Purkait, P
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (01) : 144 - 154
  • [4] Effect of Thermal Transient on the Polarization and Depolarization Current Measurements of Oil-Paper Insulation
    Fofana, I.
    Hemmatjou, H.
    Meghnefi, F.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (02) : 513 - 520
  • [5] Importance of Depolarization Current in the Diagnosis of Oil-Paper Insulation of Power Transformer
    Kumar, Alok
    Mishra, Deepak
    Baral, Arijit
    [J]. IEEE ACCESS, 2023, 11 : 56858 - 56864
  • [6] Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements
    Saha, TK
    Darveniza, M
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 463 - 466
  • [7] Study on assessing the ageing Condition of Oil-Paper Insulation by Polarization/Depolarization Current
    Xu JiQuan
    Yang Lijun
    Li Bin
    Liao Ruijin
    He Yunhua
    Guo Pei
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 617 - 621
  • [8] Analysis of Dielectric Response Measurements for Condition Assessment of Oil-Paper Transformer Insulation
    Koch, Maik
    Prevost, Thomas
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1908 - 1915
  • [9] Surface and Interface Charge Accumulation and Decay of Oil-paper Insulation under DC Voltage
    Du, B. X.
    Zhu, W. B.
    Zhang, J. G.
    Li, X. L.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 939 - 946
  • [10] Influence of Aging Degree on Polarization and Depolarization Currents of Oil-paper Insulation
    Li Xiao
    Liao Ruijin
    Li Maochang
    Yang Lijun
    Yang Junkun
    Qi Chaoliang
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 612 - 616