Total heat recovery of gas boiler by absorption heat pump and direct-contact heat exchanger

被引:96
|
作者
Zhu, Kan [1 ]
Xia, Jianjun [1 ]
Xie, Xiaoyun [1 ]
Jiang, Yi [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing, Peoples R China
关键词
Heat recovery; Condensing heat; Gas boiler; Absorption heat pump; Direct-contact heat exchanger; CONDENSING BOILERS; FIRED BOILER; SYSTEM;
D O I
10.1016/j.applthermaleng.2014.06.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a new technology which combines the absorption heat pump and the direct-contact heat exchanger. Based on the analysis of natural gas features and thermal efficiency of the gas boilers, it analyzes existing and new techniques for heat recovery, focusing upon removing heat from the flue gas to a point where it can be below the dew point as significant to realizing the total heat recovery for the gas boiler. Through field test and experimental analysis of an actual case in a district heating system operating at various system load, this paper strives to identify challenges related to high return water temperature, achieving a low-temperature cold source, and enhancing the heat transfer effect; while observing if the system performance is satisfactory, and whether the system can achieve very stable performance under different working conditions and realize the total design heat capacity improvement of 12%. Data will be examined for boiler load and its influences on the condensing rate with suggestions for further improvements. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [1] Application of absorption heat pump and direct-contact total heat exchanger to advanced-recovery flue-gas waste heat for gas boiler
    Li Feng
    Lin, Duanmu
    Fu Lin
    Zhao Xiling
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (02) : 149 - 155
  • [2] Experimental and simulation study on heat and mass transfer characteristics in direct-contact total heat exchanger for flue gas heat recovery
    Wei, Hongyang
    Huang, Shifang
    Zhang, Xiaosong
    [J]. APPLIED THERMAL ENGINEERING, 2022, 200
  • [3] Heat storage in direct-contact heat exchanger with phase change material
    Nomura, Takahiro
    Tsubota, Masakatsu
    Oya, Teppei
    Okinaka, Noriyuki
    Akiyama, Tomohiro
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 26 - 34
  • [4] Stability of a Direct-Contact Spray Column Heat Exchanger
    Golafshani, M.
    Jacobs, H. R.
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 767 - 772
  • [5] New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement
    Qu, Ming
    Abdelaziz, Omar
    Yin, Hongxi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 175 - 184
  • [6] COMPUTER MODELING OF A DIRECT-CONTACT CONDENSING HEAT-EXCHANGER FOR GAS FURNACES
    CHRISTENSEN, RN
    LIU, Q
    TALBERT, SG
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1994, 14 (02): : 195 - 209
  • [7] Theoretical and experimental study of volumetric heat transfer coefficient for Direct-Contact Heat Exchanger
    Huang, Junwei
    Wang, Shibo
    Hu, Jianhang
    [J]. ADVANCES IN ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2016, : 367 - 373
  • [8] Improvement on Heat Release Performance of Direct-contact Heat Exchanger Using Phase Change Material for Recovery of Low Temperature Exhaust Heat
    Nomura, Takahiro
    Tsubota, Masakatsu
    Okinaka, Noriyuki
    Akiyama, Tomohiro
    [J]. ISIJ INTERNATIONAL, 2015, 55 (02) : 441 - 447
  • [9] Heat release performance of direct-contact heat exchanger with erythritol as phase change material
    Nomura, Takahiro
    Tsubota, Masakatsu
    Oya, Teppei
    Okinaka, Noriyuki
    Akiyama, Tomohiro
    [J]. APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 28 - 35
  • [10] A total heat recovery system between the flue gas and oxidizing air of a gas-fired boiler using a non-contact total heat exchanger
    Shang, Sheng
    Li, Xianting
    Chen, Wei
    Wang, Baolong
    Shi, Wenxing
    [J]. APPLIED ENERGY, 2017, 207 : 613 - 623