Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: A comparative in vitro study between machined and plasma-sprayed titanium surfaces

被引:23
|
作者
Chairay, JP
Boulekbache, H
Jean, A
Soyer, A
Bouchard, P
机构
[1] Denis Diderot Univ, Sch Dent, Dept Periodontol, Paris, France
[2] Dev Biol Lab, Paris, France
[3] Mineral Crystallog Lab, Paris, France
关键词
titanium; dental implants; air abrasion; comparison study;
D O I
10.1902/jop.1997.68.12.1215
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AN LN VITRO COMPARATIVE study was conducted in order to evaluate the effects of an air-abrasive system on dental implant surfaces. Eight new titanium dental implants, four standard machined implants (machined group), and four standard plasma-sprayed implants (plasma-sprayed group) were selected for investigation. Both neck and body surfaces of the implants were analyzed. Each pair of implants in each, group was treated as follows: the spray of the air-abrasive unit was applied to each area for 5 seconds on the first implant and 15 seconds on the second implant. A total of 24 areas were observed: 16 test implants and 8 controls. Scanning electron photomicrographs were analyzed by 3 examiners using a category rating scale (kappa = 0.594). The images were also computerized for texture analysis. The results indicate that a single air-powder abrasive treatment of the dental implants selected for this study modified their exposed surfaces. After treatment, the threaded neck surface of a machined group implant was least affected, whereas the body was the most altered. In the plasma-sprayed group, comparisons between implant surfaces showed little change. In the machined group, more change was observed in both neck and body areas. In all specimens, a 5-second exposure to the air-powder abrasive did not induce deep changes in the surfaces. A 15-second exposure modified all the specimen surfaces. Further studies are needed to evaluate the effect of these changes on the biological osseointegration process.
引用
收藏
页码:1215 / 1222
页数:8
相关论文
共 4 条
  • [1] Microvascular changes after placement of titanium implants: Scanning electron microscopy observations of machined and titanium plasma-sprayed implants in dogs
    Matsuo, M
    Nakamura, T
    Kishi, Y
    Takahashi, K
    JOURNAL OF PERIODONTOLOGY, 1999, 70 (11) : 1330 - 1338
  • [2] The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Topography of Implant Surfaces: Scanning Electron Analysis and In Vitro Study
    Gianfreda, Francesco
    Marenzi, Gaetano
    Nicolai, Eleonora
    Muzzi, Maurizio
    Bari, Monica
    Bernardini, Sergio
    Adamo, Daniela
    Miniello, Alessandra
    Sammartino, Gilberto
    Bollero, Patrizio
    EUROPEAN JOURNAL OF DENTISTRY, 2024,
  • [3] Comparative in vitro analysis of vacuum plasma-sprayed titanium implants -: Evaluation of OPG, osteokalzin and AP expression
    Endres, S.
    Wilke, M.
    Knoell, P.
    Frank, H.
    Kratz, M.
    Windler, M.
    Wilke, A.
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2006, 144 (06): : 632 - 638
  • [4] The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study
    Gianfreda, Francesco
    Bollero, Patrizio
    Muzzi, Maurizio
    Di Giulio, Andrea
    Nicolai, Eleonora
    Canullo, Luigi
    DENTISTRY JOURNAL, 2022, 10 (03)