The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

被引:52
|
作者
Chen, Ligang [1 ]
Ding, Lan [1 ]
Jin, Haiyan [1 ]
Song, Daqian [1 ]
Zhang, Huarong [1 ]
Li, Jiantao [1 ]
Zhang, Kun [1 ]
Wang, Yutang [1 ]
Zhang, Hanqi [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
关键词
dynamic microwave-assisted extraction; solid-phase extraction; high-performance liquid chromatography (HPLC); on-line determination; organochlorine pesticides; grain;
D O I
10.1016/j.aca.2007.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min(-1). The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g(-1). The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required. circle star 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [1] Dynamic microwave-assisted extraction coupled on-line with solid-phase extraction:: determination of polycyclic aromatic hydrocarbons in sediment and soil
    Ericsson, M
    Colmsjö, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 964 (1-2) : 11 - 20
  • [2] High-throughput dynamic microwave-assisted extraction on-line coupled with solid-phase extraction for analysis of nicotine in mushroom
    Wang, Hui
    Zhao, Qi
    Song, Weitao
    Xu, Yang
    Zhang, Xiaopan
    Zeng, Qinglei
    Chen, Haiyan
    Ding, Lan
    Ren, Nanqi
    [J]. TALANTA, 2011, 85 (01) : 743 - 748
  • [3] On-line coupling of dynamic microwave-assisted extraction to solid-phase extraction for the determination of sulfonamide antibiotics in soil
    Chen, Ligang
    Zeng, Qinglei
    Wang, Hui
    Su, Rui
    Xu, Yang
    Zhang, Xiaopan
    Yu, Aimin
    Zhang, Hanqi
    Ding, Lan
    [J]. ANALYTICA CHIMICA ACTA, 2009, 648 (02) : 200 - 206
  • [4] Application of microwave-assisted micellar extraction combined with solid-phase microextraction and high-performance liquid chromatography with UV detection for the determination of organochlorine pesticides in different mud samples
    Vega, Daura
    Sosa, Zoraida
    Juan Santana-Rodriguez, Jose
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (03) : 185 - 197
  • [5] On-line solid-phase extraction and high performance liquid chromatography for the determination of bromide
    Jain, A
    Mishra, S
    Sahasrabuddhey, B
    Verma, KK
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1997, 36 (10): : 908 - 912
  • [6] Determination of Morphine in Pharmaceutical Products by On-Line Solid-Phase Extraction and High-Performance Liquid Chromatography
    Yang, Yan-Ling
    Ye, Xiao-Xue
    Li, Yu-Sang
    Tan, Zhi-Fang
    Jiang, Ji-Zhou
    [J]. ANALYTICAL LETTERS, 2016, 49 (09) : 1303 - 1309
  • [7] On-line coupling of solid-phase extraction to high-performance liquid chromatography for determination of estrogens in environment
    Wang, Shuo
    Huang, Wei
    Fang, Guozhen
    He, Jinxing
    Zhang, Yan
    [J]. ANALYTICA CHIMICA ACTA, 2008, 606 (02) : 194 - 201
  • [8] Determination of tetracyclines residues in honey by on-line solid-phase extraction high-performance liquid chromatography
    Li, Jiantao
    Chen, Ligang
    Wang, Xiao
    Jin, Haiyan
    Ding, Lan
    Zhang, Kun
    Zhang, Hanqi
    [J]. TALANTA, 2008, 75 (05) : 1245 - 1252
  • [9] Dynamic microwave-assisted extraction coupled on-line with solid-phase extraction and large-volume injection gas chromatography:: Determination of organophosphate esters in air samples
    Ericsson, M
    Colmsjö, A
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1713 - 1719
  • [10] On-line coupling of dynamic microwave-assisted extraction with high-performance liquid chromatography for determination of andrographolide and dehydroandrographolide in Andrographis paniculata Nees
    Chen, Ligang
    Jin, Haiyan
    Ding, Lan
    Zhang, Huarong
    Wang, Xiupin
    Wang, Ziming
    Li, Juan
    Qu, Chenling
    Wang, Yutang
    Zhang, Hanqi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) : 71 - 77