Two-stage high frequency pulse tube cooler for refrigeration at 25 K

被引:44
|
作者
Dietrich, M. [1 ]
Thummes, G.
机构
[1] Univ Giessen Klinikum, Inst Appl Phys, D-35392 Giessen, Germany
关键词
Pulse tube; Power applications;
D O I
10.1016/j.cryogenics.2010.01.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first-stage, since the intended application requires no cooling power at this intermediate temperature. Simulations where done using SAGE-software to find optimum operating conditions and cold head geometry. Flow-impedance matching was required to connect the compressor designed for 60 Hz operation to the 40 Hz cold head. A cooling power of 12.9 W at 25 K with an electrical input power of 4.6 kW has been achieved up to now. The lowest temperature reached is 13.7 K. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [1] High capacity two-stage coaxial pulse tube cooler
    Jaco, C.
    Nguyen, T.
    Tward, E.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 530 - 537
  • [2] Performance study on a two-stage 4 K pulse tube cooler
    Wang, C
    Thummes, G
    Heiden, C
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 2055 - 2062
  • [3] A two-stage pulse tube cooler operating below 4 K
    Wang, C
    Thummes, G
    Heiden, C
    [J]. CRYOGENICS, 1997, 37 (03) : 159 - 164
  • [4] Research of two-stage high frequency pulse tube cooler using lead regenerative materials
    Yang, Lu-Wei
    Dietrich, Marc
    Thummes, Guenter
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2007, 28 (SUPPL. 1): : 33 - 36
  • [5] Study of staging method for a 25 K two stage pulse tube cooler
    Kumar, Kranthi J.
    Jacob, S.
    Karunanithi, R.
    Narasimham, G. S. V. L.
    [J]. 27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [6] Study on high frequency two-stage pulse tube refrigeration at 35 K: Part II. Experimental verification
    Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
    [J]. Zhejiang Daxue Xuebao (Gongxue Ban), 2009, 8 (1454-1457): : 1454 - 1457
  • [7] GM-type two-stage pulse tube cooler with high efficiency
    Hofmann, A
    Pan, H
    Oellrich, L
    [J]. CRYOCOOLERS 11, 2001, : 221 - 227
  • [8] CHARACTERIZATION OF A TWO-STAGE PULSE TUBE COOLER FOR SPACE APPLICATIONS
    Orsini, R.
    Nguyen, T.
    Colbert, R.
    Raab, J.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 410 - 417
  • [9] Two-stage pulse tube cooler for operation of a Josephson voltage standard near 4 K
    Qiu, LM
    Thummes, G
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 625 - 632
  • [10] Two-stage high frequency pulse tube refrigerator with base temperature below 10 K
    Chen Liubiao
    Wu Xianlin
    Liu Sixue
    Zhu Xiaoshuang
    Pan Changzhao
    Guo Jia
    Zhou Yuan
    Wang Junjie
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278