Electrocardiographic Imaging of Repolarization Abnormalities

被引:17
|
作者
Bear, Laura R. [1 ,2 ,3 ]
Cluitmans, Matthijs [4 ]
Abell, Emma [1 ,2 ,3 ]
Rogier, Julien [7 ]
Labrousse, Louis [1 ,6 ]
Cheng, Leo K. [8 ]
LeGrice, Ian [8 ]
Lever, Nigel [8 ]
Sands, Gregory B. [8 ]
Smaill, Bruce [8 ]
Haissaguerre, Michel [1 ,2 ,3 ,5 ]
Bernus, Olivier [1 ,2 ,3 ]
Coronel, Ruben [1 ,9 ]
Dubois, Remi [1 ,2 ,3 ]
机构
[1] Fdn Bordeaux Univ, IHU LIRYC, Pessac, France
[2] Univ Bordeaux, CRCTB U1045, Bordeaux, France
[3] CRCTB, INSERM, U1045, Pessac, France
[4] Maastricht UMC, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[5] Bordeaux Univ Hosp CHU, Dept Cardiac Electrophysiol & Stimulat, Pessac, France
[6] CHU, Dept Cardiac Surg, Pessac, France
[7] CHU, Organ Procurement Unit, Pessac, France
[8] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
[9] Acad Med Ctr, Dept Expt Cardiol, Amsterdam, Netherlands
来源
基金
欧洲研究理事会;
关键词
ECG; electrocardiographic imaging; electrocardiography; electrophysiology mapping; repolarization;
D O I
10.1161/JAHA.120.020153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Dispersion and gradients in repolarization have been associated with life-threatening arrhythmias, but are difficult to quantify precisely from surface electrocardiography. The objective of this study was to evaluate electrocardiographic imaging (ECGI) to noninvasively detect repolarization-based abnormalities. Methods and Results Ex vivo data were obtained from Langendorff-perfused pig hearts (n=8) and a human donor heart. Unipolar electrograms were recorded simultaneously during sinus rhythm from an epicardial sock and the torso-shaped tank within which the heart was suspended. Regional repolarization heterogeneities were introduced through perfusion of dofetilide and pinacidil into separate perfusion beds. In vivo data included torso and epicardial potentials recorded simultaneously in anesthetized, closed-chest pigs (n=5), during sinus rhythm, and ventricular pacing. For both data sets, ECGI accurately reconstructed T-wave electrogram morphologies when compared with those recorded by the sock (ex vivo: correlation coefficient, 0.85 [0.52-0.96], in vivo: correlation coefficient, 0.86 [0.52-0.96]) and repolarization time maps (ex-vivo: correlation coefficient, 0.73 [0.63-0.83], in vivo: correlation coefficient, 0.76 [0.67-0.82]). ECGI-reconstructed repolarization time distributions were strongly correlated to those measured by the sock (both data sets, R-2 >= 0.92). Although the position of the gradient was slightly shifted by 8.3 (0-13.9) mm, the mean, max, and SD between ECGI and recorded gradient values were highly correlated (R-2=0.87, 0.75, and 0.86 respectively). There was no significant difference in ECGI accuracy between ex vivo and in vivo data. Conclusions ECGI reliably and accurately maps potentially critical repolarization abnormalities. This noninvasive approach allows imaging and quantifying individual parameters of abnormal repolarization-based substrates in patients with arrhythmogenesis, to improve diagnosis and risk stratification.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Electrocardiographic repolarization abnormalities in subarachnoid hemorrhage
    Sommargren, CE
    Zaroff, JG
    Banki, N
    Drew, BJ
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 : 257 - 262
  • [2] Noninvasive Mapping of Repolarization With Electrocardiographic Imaging
    Rudy, Yoram
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (09):
  • [4] Inferior and Lateral Electrocardiographic Repolarization Abnormalities in Brugada Syndrome
    Sarkozy, Andrea
    Chierchia, Gian-Battista
    Paparella, Gaetano
    Boussy, Tim
    De Asmundis, Carlo
    Roos, Marcus
    Henkens, Stefan
    Kaufman, Leonard
    Buyl, Ronald
    Brugada, Ramon
    Brugada, Josep
    Brugada, Pedro
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (02): : 154 - 161
  • [5] Concurrent electrocardiographic repolarization abnormalities: What is the underlying channelopathy?
    Ali, Hussam
    Lupo, Pierpaolo
    De Ambroggi, Guido
    Cappato, Riccardo
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (05) : 771 - 772
  • [6] Abnormalities in electrocardiographic ventricular repolarization in patients with dengue virus infection
    Furlan-Daniel, Rosemary Aparecida
    Silveira Santos, Luis Felipe
    Magalhaes Geleilete, Tufik Jose
    Araujo Restini, Carolina Baraldi
    Bestetti, Reinaldo Bulgarelli
    [J]. JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2019, 13 (08): : 759 - 763
  • [7] Modelling and imaging cardiac repolarization abnormalities
    Rudy, Y
    [J]. JOURNAL OF INTERNAL MEDICINE, 2006, 259 (01) : 91 - 106
  • [8] ELECTROCARDIOGRAPHIC REPOLARIZATION
    STATTERS, DJ
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (06) : 1224 - 1225
  • [9] Electrocardiographic repolarization abnormalities in familial dysautonomia: an indicator of cardiac autonomic dysfunction
    Glickstein, JS
    Axelrod, FB
    Friedman, D
    [J]. CLINICAL AUTONOMIC RESEARCH, 1999, 9 (02) : 109 - 112
  • [10] Electrocardiographic Repolarization Abnormalities and Electroanatomic Substrate in Arrhythmogenic Right Ventricular Cardiomyopathy
    Kubala, Maciej
    Pathak, Rajeev K.
    Xie, Shuanglun
    Arroyo, Ruben Casado
    Tschabrunn, Cory M.
    Hayashi, Tatsuya
    Garcia, Fermin C.
    Supple, Gregory E.
    Santangeli, Pasquale
    Frankel, David S.
    Zado, Erica S.
    Callans, David J.
    Marchlinski, Francis E.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (03):