Performance Evaluation of rPPG Approaches with and without the Region-of-Interest Localization Step

被引:2
|
作者
Pirnar, Zan [1 ]
Finzgar, Miha [1 ]
Podrzaj, Primoz [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, Askerceva Cesta 6, Ljubljana 1000, Slovenia
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 08期
关键词
remote photoplethysmography; vital signs monitoring; remote sensing; NONCONTACT;
D O I
10.3390/app11083467
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Traditionally, the first step in physiological measurements based on remote photoplethysmography (rPPG) is localizing the region of interest (ROI) that contains a desired pulsatile information. Recently, approaches that do not require this step have been proposed. The purpose of this study was to evaluate the performance of selected approaches with and without ROI localization step in rPPG signal extraction. The Viola-Jones face detector and Kanade-Lucas-Tomasi tracker (VK) in combination with (a) a region-of-interest (ROI) cropping, (b) facial landmarks, (c) skin-color segmentation, and (d) skin detection based on maximization of mutual information and an approach without ROI localization step (Full Video Pulse (FVP)) were studied. Final rPPG signals were extracted using selected model-based and data-driven rPPG algorithms. The performance of the approaches was tested on three publicly available data sets offering compressed and uncompressed video recordings covering various scenarios. The success rates of pulse waveform signal extraction range from 88.37% (VK with skin-color segmentation) to 100% (FVP). In challenging scenarios (skin tone, lighting conditions, exercise), there were no statistically significant differences between the studied approaches in terms of SNR. The best overall performance in terms of RMSE was achieved by a combination of VK with ROI cropping and the model-based rPPG algorithm. Results indicate that the selection of the ROI localization approach does not significantly affect rPPG measurements if combined with a robust algorithm for rPPG signal extraction.
引用
收藏
页数:17
相关论文
共 43 条
  • [1] Translational calibration in region-of-interest localization for palmprint recognition
    Liao, Fengxiang
    Wu, Tengfei
    Gao, Fumeng
    Leng, Lu
    [J]. VISUAL COMPUTER, 2024, 40 (10): : 7293 - 7305
  • [2] Evaluation of Effective Dose in Region-Of-Interest Neuroimaging
    Gill, K.
    Bednarek, D.
    Rudin, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] LEAST-SQUARES ALGORITHM FOR REGION-OF-INTEREST EVALUATION IN EMISSION TOMOGRAPHY
    FORMICONI, AR
    PASSERI, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 588 - 588
  • [5] Evaluation of Region-of-Interest coders using perceptual image quality assessments
    Garcia-Alvarez, J. C.
    Fuhr, H.
    Castellanos-Dominguez, G.
    [J]. JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2013, 24 (08) : 1316 - 1327
  • [6] LEAST-SQUARES ALGORITHM FOR REGION-OF-INTEREST EVALUATION IN EMISSION TOMOGRAPHY
    FORMICONI, AR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (01) : 90 - 100
  • [7] Two-step Iterative Reconstruction of Region-of-Interest with Truncated Projection in Computed Tomography
    Yamakawa, Keisuke
    Kojima, Shinichi
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] High-Performance Region-of-Interest Image Error Concealment with Hiding Technique
    Hsia, Shih-Chang
    Wang, Szu-Hong
    Chen, Ming-Huei
    [J]. JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2010, 2010
  • [9] Automated region-of-interest localization and classification for vision-based visual assessment of civil infrastructure
    Yeum, Chul Min
    Choi, Jongseong
    Dyke, Shirley J.
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2019, 18 (03): : 675 - 689
  • [10] A new method of deriving the mice cardiovascular transit time without the need of region-of-interest drawing
    Wu, HM
    Kreissl, MC
    Ladno, W
    Prins, M
    Schelbert, HR
    Huang, SC
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2674 - 2676