Mandibular slope: a reproducible and simple measure of horizontal gaze

被引:4
|
作者
George, Stephen [1 ]
Spiegel, Matthew [2 ]
Protopsaltis, Themistocles [2 ]
Buckland, Aaron J. [2 ]
Gomez, Jaime A. [3 ]
Ramchandran, Subaraman [1 ]
Lafage, Renaud [4 ]
Lafage, Virginie [4 ]
Errico, Thomas [1 ]
Lonner, Baron [5 ]
机构
[1] Nicklaus Childrens Hosp, Miami, FL USA
[2] NYU, Langone Med Ctr, New York, NY USA
[3] Montefiore Med Ctr, 111 E 210th St, Bronx, NY 10467 USA
[4] Hosp Special Surg, 535 E 70th St, New York, NY 10021 USA
[5] Mt Sinai Hosp, Icahn Sch Med, 5 E 98th St,4th Floor, New York, NY 10029 USA
关键词
Novel measurement parameter; Horizontal gaze; Mandibular slope; Sagittal spinal alignment; BROW VERTICAL ANGLE; SPINAL DEFORMITY; ANKYLOSING-SPONDYLITIS; SAGITTAL BALANCE; CERVICAL-SPINE; OSTEOTOMY; ALIGNMENT;
D O I
10.1007/s43390-020-00137-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design This study is a single-center retrospective radiographic review. Objectives The objective of this study is to evaluate a novel measurement parameter, mandibular slope (MS), as a measure of horizontal gaze. Introduction Assessment of sagittal spinal alignment is essential in the evaluation of spinal deformity patients. Ability to achieve a horizontal gaze, a parameter of sagittal alignment, is needed for the performance of daily activities. Standard measures of horizontal gaze, including the gold-standard chin-brow to vertical angle (CBVA) and the surrogate measures McGregor's line (McGS) and Chamberlain's line (CS), require high-quality imaging, precise head positioning, and reliance on difficult to view visual landmarks. A novel measurement parameter, MS, utilizing the caudal margin of the mandible on standard lateral spine radiographs is proposed. Methods 90 radiographs from spine deformity patients with or without spinal implants from a single center were evaluated. Three spine surgery fellows independently measured CBVA, McGS, CS, and MS at two timepoints at least one week apart to assess accuracy and reliability. MS was measured as the angle created by the inferior edge of the mandibular body and the horizontal. Formulas for calculating CBVA based on the above parameters were derived and compared to the actual CBVA. Results Mean age was 49.7 years, 76 females and 14 males. CBVA correlated with CS, McGS, and MS, r=0.85, 0.81, and 0.80, respectively (p < 0.001). Standard error between real CBVA and calculated CBVA using CS (0.44.79) and McGS (0.4 +/- 3.9) was higher than that calculated using MS (- 0.2 +/- 4.3). ICC demonstrated the highest inter-observer reliability with MS (0.999). MS had the highest intra-observer reliabilities 0.975, 0.981, and 0.988 (p < 0.001); CS and McGS also demonstrated high intra-observer reliability. Conclusions MS is a promising measure of horizontal gaze that correlates highly with CBVA, has excellent intra- and inter-observer reliability with CBVA, and is easily measured using standard lateral spine radiographs.
引用
下载
收藏
页码:893 / 899
页数:7
相关论文
共 50 条
  • [1] Mandibular slope: a reproducible and simple measure of horizontal gaze
    Stephen George
    Matthew Spiegel
    Themistocles Protopsaltis
    Aaron J. Buckland
    Jaime A. Gomez
    Subaraman Ramchandran
    Renaud Lafage
    Virginie Lafage
    Thomas Errico
    Baron Lonner
    Spine Deformity, 2020, 8 : 893 - 899
  • [2] A simple device to measure gaze angles in visual task analyses
    Page, A.
    Mateo, B.
    Garrido-Jaen, J.
    Marzo, R.
    Duersteler, J. C.
    Gimenez, A.
    Prieto, C.
    BIODEVICES 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, VOL 1, 2008, : 119 - +
  • [3] Simple Slope Stabilization on Quartz Sandstone using Horizontal Drain
    Supandi, S.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2021, 34 (04): : 1046 - 1051
  • [4] An Experimental Investigation of Wave Forces on a Submerged Horizontal Plate over a Simple Slope
    Dong, Jie
    Xue, Leiping
    Cheng, Kaiyu
    Shi, Jian
    Zhang, Chi
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2020, 8 (07)
  • [5] Simple method to measure effects of horizontal atmospherical turbulence at ground level
    Tijaro Rojas, Omar J.
    Galeano Traslavina, Yuber A.
    Torres Moreno, Yezid
    LASER COMMUNICATION AND PROPAGATION THROUGH THE ATMOSPHERE AND OCEANS V, 2016, 9979
  • [6] Parametric study of horizontal drains for slope stability measure: A case study in Putrajaya, Malaysia
    Mohd Ashraf Mohamad Ismail
    Soon Min Ng
    Ismail Abustan
    KSCE Journal of Civil Engineering, 2017, 21 : 2162 - 2167
  • [7] Parametric study of horizontal drains for slope stability measure: A case study in Putrajaya, Malaysia
    Ismail, Mohd Ashraf Mohamad
    Ng, Soon Min
    Abustan, Ismail
    KSCE JOURNAL OF CIVIL ENGINEERING, 2017, 21 (06) : 2162 - 2167
  • [8] PARALYSIS OF HORIZONTAL GAZE WITH SCOLIOSIS
    MARCHANTE, JJA
    PEREZ, JAH
    VEGUERO, JMJ
    REVISTA CLINICA ESPANOLA, 1986, 178 (02): : 98 - 99
  • [9] MIDBRAIN PARESIS OF HORIZONTAL GAZE
    ZACKON, DH
    SHARPE, JA
    ANNALS OF NEUROLOGY, 1984, 16 (04) : 495 - 504
  • [10] FUNCTIONAL PARALYSIS OF HORIZONTAL GAZE
    TROOST, BT
    TROOST, EG
    NEUROLOGY, 1979, 29 (01) : 82 - 85