Surface plasmon resonance/mass spectrometry interface

被引:38
|
作者
Grote, J
Dankbar, N
Gedig, E
Koenig, S
机构
[1] Univ Munster, Fac Med, Interdisciplinary Ctr Clin Res, D-48149 Munster, Germany
[2] XanTec Bioanalyt GmbH, Munster, Germany
关键词
D O I
10.1021/ac049033d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A strategy for combining surface plasmon resonance (SPR) biomolecular interaction analysis, and matrixassisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. Both techniques are highly complementary but need separate optimization to improve their individual specificity and sensitivity. Sensor surfaces that are optimal for kinetic analysis are not well suited for MALDI-MS and vice versa. In addition, the transfer of analyte from SPR to MS is crucial and often accompanied by sample loss. To address both of these points, a bifunctional SPR fluid cell was constructed where optimized surfaces can be used for binding studies and MS simultaneously with regard to the special need of each technique. The setup guarantees that the SPR and the loading experiment for MS are performed at identical conditions. A removable pin carries the affinity-surface-bound analyte to the mass spectrometer so that handling is minimized, avoiding analyte elution. Functionalized transfer pins can also be used independently of SPR for microaffinity capture-MS.
引用
收藏
页码:1157 / 1162
页数:6
相关论文
共 50 条
  • [1] Surface plasmon resonance mass spectrometry in proteomics
    Visser, Natasja F. C.
    Heck, Albert J. R.
    EXPERT REVIEW OF PROTEOMICS, 2008, 5 (03) : 425 - 433
  • [2] Interface for Online Coupling of Surface Plasmon Resonance to Direct Analysis in Real Time Mass Spectrometry
    Zhang, Yiding
    Li, Xianjiang
    Nie, Honggang
    Yang, Li
    Li, Ze
    Bai, Yu
    Niu, Li
    Song, Daqian
    Liu, Huwei
    ANALYTICAL CHEMISTRY, 2015, 87 (13) : 6505 - 6509
  • [3] Development of surface plasmon resonance mass spectrometry array platform
    Nedelkov, Dobrin
    ANALYTICAL CHEMISTRY, 2007, 79 (15) : 5987 - 5990
  • [4] Surface plasmon resonance mass spectrometry: recent progress and outlooks
    Nedelkov, D
    Nelson, RW
    TRENDS IN BIOTECHNOLOGY, 2003, 21 (07) : 301 - 305
  • [5] Surface plasmon resonance-enabled mass spectrometry arrays
    Nedelkov, Dobrin
    Tubbs, Kemmons A.
    Nelson, Randall W.
    ELECTROPHORESIS, 2006, 27 (18) : 3671 - 3675
  • [6] A dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry
    Zhang, Yiding
    Xu, Shuting
    Wen, Luhong
    Bai, Yu
    Niu, Li
    Song, Daqian
    Liu, Huwei
    ANALYST, 2016, 141 (11) : 3343 - 3348
  • [7] Screening for enzyme inhibitors by surface plasmon resonance combined with mass spectrometry
    Borch, J
    Roepstorff, P
    ANALYTICAL CHEMISTRY, 2004, 76 (18) : 5243 - 5248
  • [8] Optimizing the surface plasmon resonance/mass spectrometry interface for functional proteomics applications:: How to avoid and utilize nonspecific adsorption
    Larsericsdotter, H
    Jansson, Ö
    Zhukov, A
    Areskoug, D
    Oscarsson, S
    Buijs, J
    PROTEOMICS, 2006, 6 (08) : 2355 - 2364
  • [9] Biochip Spray: Simplified Coupling of Surface Plasmon Resonance Biosensing and Mass Spectrometry
    Joshi, Sweccha
    Zuilhof, Han
    van Beek, Teris A.
    Nielen, Michel W. F.
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1427 - 1432
  • [10] Longitudinal Surface Plasmon Resonance Based Gold Nanorod Biosensors for Mass Spectrometry
    Castellana, Edward T.
    Gamez, Roberto C.
    Gomez, Mario E.
    Russell, David H.
    LANGMUIR, 2010, 26 (08) : 6066 - 6070