Minimum 10-year results of cementless total hip arthroplasty in patients with rheumatoid arthritis

被引:6
|
作者
Haraguchi, Akihisa [1 ]
Nakashima, Yasuharu [1 ]
Miyahara, Hisaaki [2 ]
Esaki, Yukio [2 ]
Okazaki, Ken [1 ]
Fukushi, Jun-ichi [1 ]
Hirata, Go [2 ]
Ikemura, Satoshi [1 ]
Kamura, Satoshi [2 ]
Sakuraba, Koji [2 ]
Fujimura, Kenjiro [2 ]
Akasaki, Yukio [1 ]
Yamada, Hisakata [3 ]
机构
[1] Kyushu Univ, Dept Orthopaed Surg, Fukuoka, Japan
[2] Natl Hosp Org Kyushu Med Ctr, Dept Orthoped, Fukuoka, Japan
[3] Kondo Clin Rheumatol & Orthopaed Surg, Fukuoka, Japan
基金
日本学术振兴会;
关键词
Cementless total hip arthroplasty; Long-term results; Mortality; Rheumatoid arthritis; PERIPROSTHETIC FEMORAL FRACTURES; CROSS-LINKED POLYETHYLENE; TOTAL JOINT ARTHROPLASTY; POPULATION-BASED COHORT; FOLLOW-UP; CARDIOVASCULAR EVENTS; ORAL GLUCOCORTICOIDS; MORTALITY; RISK; CLASSIFICATION;
D O I
10.1080/14397595.2016.1256024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To retrospectively evaluate the long-term results of cementless total hip arthroplasty (THA) in patients with rheumatoid arthritis (RA) and postoperative patient mortality after THA. Methods: This study included 191 hips in 149 RA patients who underwent cementless THA between 1998 and 2005. Mean age at surgery was 54.2 years, and mean follow-up was 12.6 years. Implant and patient survivorships were determined using the Kaplan-Meier method, and the associated influencing factors were determined. Results: Implant survivals at 17 years were 99.5% for stems, 93.9% for cups, and 90.8% for liners. Among the liners used, THAs with highly cross-linked polyethylene showed better survivals compared with those with conventional polyethylene and alumina-bearing surface (93.4%, 90.9%, and 52.2%, respectively). A total of 64 deaths occurred; 45 patients died within 10 years and 19 patients died between 10 and 17 years. Malignancy (25.0%) was the leading cause of death, followed by pneumonia (20.8%) and sepsis (20.8%). The patient survival rate was 36.9% at 17 years after THA. Multivariate analysis exhibited that older age at operation and greater dose of concomitant corticosteroid resulted in shorter patient survivals. Conclusions: Cementless THA worked well in patients with RA. Mortality remained high among RA patients who needed THA.
引用
收藏
页码:598 / 604
页数:7
相关论文
共 50 条
  • [1] Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results
    Hans D. Carl
    Jan Ploetzner
    Bernd Swoboda
    Gerd Weseloh
    Lutz Arne Mueller
    [J]. Rheumatology International, 2011, 31 : 353 - 359
  • [2] Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results
    Carl, Hans D.
    Ploetzner, Jan
    Swoboda, Bernd
    Weseloh, Gerd
    Mueller, Lutz Arne
    [J]. RHEUMATOLOGY INTERNATIONAL, 2011, 31 (03) : 353 - 359
  • [3] Cementless total hip arthroplasty for patients with rheumatoid arthritis: a more than 10-year follow-up
    Yuasa T.
    Maezawa K.
    Nozawa M.
    Kaneko K.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (6) : 599 - 603
  • [4] Long-term clinical and radiographic results of cementless total hip arthroplasty for patients with rheumatoid arthritis: minimal 10-year follow-up
    Matsushita, Isao
    Morita, Yuji
    Ito, Yoshiaki
    Motomura, Hiraku
    Kimura, Tomoatsu
    [J]. MODERN RHEUMATOLOGY, 2014, 24 (02) : 281 - 284
  • [5] Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty
    Mallory, TH
    Lombardi, AV
    Leith, JR
    Fujita, H
    Hartman, JF
    Capps, SG
    Kefauver, CA
    Adams, JB
    Vorys, GC
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 49 - 54
  • [6] Minimum 10-year results of a tapered cementless hip replacement
    Sakalkale, DP
    Eng, K
    Hozack, WJ
    Rothman, RH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (362) : 138 - 144
  • [7] Omnifit cementless total hip arthroplasty - A 10-year average followup
    Hellman, EJ
    Capello, WN
    Feinberg, JR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (364) : 164 - 174
  • [8] Cementless total hip arthroplasty in young patients under the age of 30: a minimum 10-year follow-up
    Shin, Eun Ho
    Moon, Kyoung Ho
    [J]. HIP INTERNATIONAL, 2018, 28 (05) : 507 - 513
  • [9] Minimum 10-Year Results of Modular Metal-On-Metal Total Hip Arthroplasty
    Wakabayashi, Hiroki
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [10] Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty - Minimum 5-year results
    Keisu, KS
    Orozco, F
    McCallum, JD
    Bissett, G
    Hozack, WJ
    Sharkey, PF
    Rothman, RH
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (04): : 415 - 421