Sheathless capillary electrophoresis-mass spectrometry for anionic metabolic profiling

被引:55
|
作者
Gulersonmez, Mehmet Can [1 ]
Lock, Stephen [2 ]
Hankemeier, Thomas [1 ]
Ramautar, Rawi [1 ]
机构
[1] Leiden Univ, Div Analyt Biosci, Leiden Acad Ctr Drug Res, NL-2333 CC Leiden, Netherlands
[2] SCIEX Ltd, Phoenix House,Ctr Pk, Warrington, Cheshire, England
关键词
Anionic metabolites; Glioblastoma cell line; Mass spectrometry; Metabolic profiling; Sheathless porous tip interface; CE-MS; TIME; NUCLEOTIDES; ELECTROLYTE; INTERFACE; PLATFORM;
D O I
10.1002/elps.201500435
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of CE coupled on-line to MS via a sheathless porous tip sprayer was evaluated for anionic metabolic profiling. A representative metabolite mixture and biological samples were used for the evaluation of various analytical parameters, such as peak efficiency (plate numbers), migration time and peak area repeatability, and LODs. The BGE, i.e. 10% acetic acid (pH 2.2), previously used for cationic metabolic profiling was now assessed for anionic metabolic profiling by using MS detection in negative ion mode. For test compounds, RSDs for migration times and peak areas were below 2 and 11%, respectively, and plate numbers ranged from 60 000 to 40 0000 demonstrating a high separation efficiency. Critical metabolites with low or no retention on reversed-phase LC could be efficiently separated and selectively analyzed by the sheathless CE-MS method. An injection volume of only circa 20 nL resulted in LODs between 10 and 200 nM (corresponding to an amount of 0.4-4 fmol), which was an at least tenfold improvement as compared to LODs obtained by conventional CE-MS approaches for these analytes. The methodology was applied to anionic metabolic profiling of glioblastoma cell line extracts. Overall, a sheathless CE-MS method has been developed for highly efficient and sensitive anionicmetabolic profiling studies, which can also be used for cationic metabolic profiling studies by only switching the MS detection and separation voltage polarity.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 50 条
  • [1] Sheathless Capillary Electrophoresis-Mass Spectrometry for Metabolic Profiling of Biological Samples
    Zhang, Wei
    Gulersonmez, M. Can
    Hankemeier, Thomas
    Ramautar, Rawi
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (116):
  • [2] Utility of sheathless capillary electrophoresis-mass spectrometry for metabolic profiling of limited sample amounts
    Zhang, Wei
    Guled, Faisa
    Hankemeier, Thomas
    Ramautar, Rawi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1105 : 10 - 14
  • [3] Comparison of capillary electrophoresis-mass spectrometry and hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine
    Kok, Miranda G. M.
    Somsen, Govert W.
    de Jong, Gerhardus J.
    [J]. TALANTA, 2015, 132 : 1 - 7
  • [4] Anionic metabolic profiling of urine from antibiotic-treated rats by capillary electrophoresis-mass spectrometry
    Kok, Miranda G. M.
    Ruijken, Marco M. A.
    Swann, Jonathan R.
    Wilson, Ian D.
    Somsen, Govert W.
    de Jong, Gerhardus J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (08) : 2585 - 2594
  • [5] Enhancing the Coverage of the Urinary Metabolome by Sheathless Capillary Electrophoresis-Mass Spectrometry
    Ramautar, Rawi
    Busnel, Jean-Marc
    Deelder, Andre M.
    Mayboroda, Oleg A.
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (02) : 885 - 892
  • [6] Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source
    Chao, Bing-Fong
    Chen, Chao-Jung
    Li, Fu-An
    Her, Guor-Rong
    [J]. ELECTROPHORESIS, 2006, 27 (11) : 2083 - 2090
  • [7] Intact monoclonal antibodies separation and analysis by sheathless capillary electrophoresis-mass spectrometry
    Giorgetti, Jeremie
    Lechner, Antony
    Del Nero, Elise
    Beck, Alain
    Francois, Yannis-Nicolas
    Leize-Wagner, Emmanuelle
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2019, 25 (03) : 324 - 332
  • [8] Low-Flow Sheathless Capillary Electrophoresis-Mass Spectrometry for Sensitive Glycoform Profiling of Intact Pharmaceutical Proteins
    Haselberg, Rob
    de Jong, Gerhardus J.
    Somsen, Govert W.
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2289 - 2296
  • [9] Capillary electrophoresis-mass spectrometry in impurity profiling of pharmaceutical products
    Visky, D
    Jimidar, I
    Van Ael, W
    Vennekens, T
    Redlich, D
    De Smet, M
    [J]. ELECTROPHORESIS, 2005, 26 (7-8) : 1541 - 1549
  • [10] An automated, sheathless capillary electrophoresis-mass spectrometry platform for discovery of biomarkers in human serum
    Sassi, AP
    Andel, F
    Bitter, HML
    Brown, MPS
    Chapman, RG
    Espiritu, J
    Greenquist, AC
    Guyon, I
    Horchi-Alegre, M
    Stults, KL
    Wainright, A
    Heller, JC
    Stults, JT
    [J]. ELECTROPHORESIS, 2005, 26 (7-8) : 1500 - 1512