Evaluation of Atopic Dermatitis Improvement Caused by Low-Level, Low-Frequency Pulsed Electromagnetic Fields

被引:3
|
作者
Kim, Jun-Young [1 ]
Lee, Ji-Young [2 ]
Lee, Ja-Woo [1 ]
Lee, Soo-Kyung [1 ]
Park, Chang-Soon [1 ]
Yang, Se-Jung [2 ]
Lee, Yong-Heum [1 ]
机构
[1] Yonsei Univ, Dept Biomed Engn, Biomed Electromagnet Syst Lab, Wonju, Gangwon Do, South Korea
[2] Yonsei Univ, Dept Biomed Engn, Lab Artificial Intelligence Biomed Imaging, Wonju, Gangwon Do, South Korea
关键词
hairless mouse; pulsed electromagnetic field; dinitrochlorobenzene; inflammation; atopic dermatitis; SKIN; SEVERITY; EXPRESSION; DISEASE; ALLERGY; PLASMA; SCORE;
D O I
10.1002/bem.22405
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to evaluate the effectiveness of using low-level, low-frequency pulsed electromagnetic field (LLLF_PEMF) stimulation to improve atopic dermatitis induced by 2,4-dinitrochlorobenzene (DNCB). Twenty 6-week-old hairless mice were randomly divided into Normal (n = 5), PEMF 15 Hz (n = 5), PEMF 75 Hz (n = 5), and Sham (n = 5) groups. Following the onset of atopic dermatitis symptoms, PEMF groups (15 and 75 Hz) were stimulated with LLLF_PEMF (15 mT) for 8 h per day for 1 week. Sensory evaluation analysis revealed a significant difference between the PEMF 15 Hz group and Sham group (P < 0.05), but these differences were not visually obvious. While both the PEMF and Sham groups had atopic dermatitis lesions, lesion size was significantly smaller in the two PEMF groups than in the Sham group (P < 0.001). Additionally, changes in epithelial thickness because of skin inflammation significantly decreased for both PEMF groups, compared with the Sham group (P < 0.001). In conclusion, these results suggest that PEMF stimulation in vivo triggers electro-chemical reactions that affect immune response. (c) 2022 Bioelectromagnetics Society.
引用
收藏
页码:268 / 277
页数:10
相关论文
共 50 条
  • [1] EXPOSURE TO LOW-LEVEL EXTREMELY LOW-FREQUENCY ELECTROMAGNETIC-FIELDS NEAR NAVAL COMMUNICATIONS FACILITIES
    ENK, JO
    ABROMAVAGE, MM
    [J]. IEEE JOURNAL OF OCEANIC ENGINEERING, 1984, 9 (03) : 136 - 142
  • [2] In vitro effects of low-level, low-frequency electromagnetic fields on DNA damage in human leucocytes by comet assay
    Ahuja, YR
    Vijayashree, B
    Saran, R
    Jayashri, EL
    Manoranjani, JK
    Bhargava, SC
    [J]. INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1999, 36 (05): : 318 - 322
  • [3] BIOLOGICAL EFFECTS OF LOW-LEVEL LOW-FREQUENCY ELECTRIC AND MAGNETIC-FIELDS
    POLK, C
    [J]. IEEE TRANSACTIONS ON EDUCATION, 1991, 34 (03) : 243 - 249
  • [4] LOW-LEVEL LOW-FREQUENCY DETECTION SYSTEM
    LARSEN, NT
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (11): : 1200 - &
  • [5] EFFECT ON MYOBLAST DIFFERENTIATION BY EXTREMELY LOW-FREQUENCY PULSED ELECTROMAGNETIC FIELDS
    Han, Fujun
    Yin, Shuang
    Wu, Hao
    Zhou, Chenliang
    Wang, Xintao
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (08)
  • [6] LOW-FREQUENCY PULSED ELECTROMAGNETIC-FIELDS INFLUENCE EEG OF MAN
    VONKLITZING, L
    [J]. PHYSICA MEDICA, 1995, 11 (02) : 77 - 80
  • [7] Computation of low-frequency electromagnetic fields
    VanRienen, U
    Clemens, M
    Weiland, T
    [J]. ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1996, 76 : 567 - 568
  • [8] Evaluation of testicular degeneration induced by low-frequency electromagnetic fields
    Tenorio, Bruno Mendes
    Jimenez, George Chaves
    de Morais, Rosana Nogueira
    Peixoto, Christina Alves
    Nogueira, Romildo de Albuquerque
    da Silva Junior, Valdemiro Amaro
    [J]. JOURNAL OF APPLIED TOXICOLOGY, 2012, 32 (03) : 210 - 218
  • [9] LOW-FREQUENCY SYNCHRONOUS AMPLIFIER WITH A LOW-LEVEL OF DRIFT
    KUZKOV, VP
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1989, 32 (01) : 173 - 174
  • [10] CLINICAL OBSERVATION OF LOW-FREQUENCY PULSED ELECTROMAGNETIC FIELDS (PEMFS) ON POSTMENOPAUSAL OSTEOPOROSIS
    Liu, Y.
    Wang, C.
    Xu, J.
    Li, P.
    He, C.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 : S750 - S751