Uricase-immobilization on radiation grafted polymer support for detection of uric acid using Ag-nanoparticle based optical biosensor

被引:26
|
作者
Kumar, Virendra [1 ]
Misra, Nilanjal [1 ]
Paul, Jhimli [1 ]
Dhanawade, B. R. [1 ]
Varshney, Lalit [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiat Technol Dev Div, Bombay 400085, Maharashtra, India
关键词
Radiation grafting; Uricase; Immobilization; COVALENT IMMOBILIZATION; HUMAN SERUM; INVERTASE; ENZYME; POLYETHYLENE; ACRYLAMIDE; MEMBRANE;
D O I
10.1016/j.polymer.2014.04.012
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A functional polymer support was designed for covalent immobilization of enzyme uricase, which was further utilized in a single enzyme based silver nanoparticles (Ag-NPs)-optical biosensor system for estimation of uric acid. A carboxylic acid functionalized polymer support was fabricated via gamma radiation induced mutual-irradiation grafting of polyacrylic acid (PAA) on to non-woven polypropylene (PP) matrix. Grafting parameters, such as dose, monomer concentration, homopolymer inhibitor and inorganic acid concentration were studied to optimize the grafting process. PAA-g-PP samples were characterized by grafting yield measurement, water uptake, FTIR, TGA and SEM techniques. Uricase enzyme was immobilized on to the PAA-g-PP support via covalent amide linkage using coupling agents, namely N-hydroxysuccinimide (NHS) and N-ethyl-N'-(3-(dimethylamino)propyl)carbodiimide (EDC). The catalytic activity of uricase was investigated spectrophotometrically using uric acid as a substrate. Study of kinetic parameters (Km. V,,,x) revealed the value of Km for covalently immobilized uricase to be similar to 1.2-fold higher than that of free enzyme. The uricase-immobilized-PAA-g-PP samples could be repeatedly used for 20 cycles over a period of 30 days when stored in phosphate buffer (pH similar to 7.4) at 4 C without significant decrease in the enzyme activity. The uricase immobilized samples were successfully used in conjunction with the radiolytically synthesized Ag-NPs as a LSPR-optical biosensor for estimation of uric acid. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2652 / 2660
页数:9
相关论文
共 35 条
  • [1] Uricase grafted nanoconducting matrix based electrochemical biosensor for ultrafast uric acid detection in human serum samples
    Verma, Shilpi
    Choudhary, Jyoti
    Singh, Krishna P.
    Chandra, Pranjal
    Singh, Surinder P.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 130 : 333 - 341
  • [2] An electrochemiluminescent biosensor based on polypyrrole immobilized uricase for ultrasensitive uric acid detection
    Chu, Haihong
    Wei, Xiuhua
    Wu, Meisheng
    Yan, Jilin
    Tu, Yifeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01) : 247 - 252
  • [3] Conductimetric Biosensor for the Detection of Uric Acid by Immobilization Uricase on Nata de Coco Membrane-Pt Electrode
    Mulyasuryani, Ani
    Srihardiastutie, Arie
    ANALYTICAL CHEMISTRY INSIGHTS, 2011, 6 : 47 - 51
  • [4] Uricase Based Enzymatic Biosensor for Non-invasive Detection of Uric Acid by Entrapment in PVA-SbQ Polymer Matrix
    RoyChoudhury, Sohini
    Umasankar, Yogeswaran
    Hutcheson, Joshua D.
    Lev-Tov, Hadar A.
    Kirsner, Robert S.
    Bhansali, Shekhar
    ELECTROANALYSIS, 2018, 30 (10) : 2374 - 2385
  • [5] An Amperomertic Uric Acid Biosensor Based on Immobilization of Uricase onto Polyaniline-multiwalled Carbon Nanotube Composite Film
    Bhambi, Manu
    Sumana, G.
    Malhotra, B. D.
    Pundir, C. S.
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2010, 38 (04): : 178 - 185
  • [6] An electrochemical biosensor based on novel butylamine capped CZTS nanoparticles immobilized by uricase for uric acid detection
    Jain, Shefali
    Verma, Shilpi
    Singh, Surinder P.
    Sharma, Shailesh Narain
    BIOSENSORS & BIOELECTRONICS, 2019, 127 : 135 - 141
  • [7] Fiber Optic SPR-Based Uric Acid Biosensor Using Uricase Entrapped Polyacrylamide Gel
    Kant, Ravi
    Tabassum, Rana
    Gupta, Banshi D.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (19) : 2050 - 2053
  • [8] An ultra-sensitive uric acid second generation biosensor based on chemical immobilization of uricase on functionalized multiwall carbon nanotube grafted palm oil fiber in the presence of a ferrocene mediator
    Deffo, Gullit
    Hazarika, Ranjit
    Ngaha, Marcel Cedric Deussi
    Basumatary, Mwina
    Kalita, Shyamali
    Hussain, Nayab
    Njanja, Evangeline
    Puzari, Panchanan
    Ngameni, Emmanuel
    ANALYTICAL METHODS, 2023, 15 (20) : 2456 - 2466
  • [9] Uricase biosensor based on a screen-printed electrode modified with Prussian blue for detection of uric acid in human blood serum
    Piermarini, Silvia
    Migliorelli, Davide
    Volpe, Giulia
    Massoud, Renato
    Pierantozzi, Andrea
    Cortese, Claudio
    Palleschi, Giuseppe
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 170 - 174
  • [10] Uric acid biosensor based on chemiluminescence detection using a nano-micro hybrid matrix
    Chaudhari, Rashmi D.
    Joshi, Abhijeet B.
    Srivastava, Rohit
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 882 - 889