Prediction of the critical heat flux for saturated upward flow boiling water in vertical narrow rectangular channels

被引:7
|
作者
Choi, Gil Sik [1 ]
Chang, Soon Heung [1 ]
JeongDepartment, Yong Hoon [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon 305380, South Korea
关键词
ANNULAR 2-PHASE FLOW; REGIME TRANSITION CRITERIA; LIQUID-FILM; DROPLET ENTRAINMENT; MINIMUM THICKNESS; TUBES; MODEL;
D O I
10.1016/j.nucengdes.2016.03.032
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A study, on the theoretical method to predict the critical heat flux (CHF) of saturated upward flow boiling water in vertical narrow rectangular channels, has been conducted.For the assessment of this CHF prediction method, 608 experimental data were selected from the previous researches, in which the heated sections were uniformly heated from both wide surfaces under the high pressure condition over 41 bar. For this purpose, representative previous liquid film dryout (LFD) models for circular channels were reviewed by using 6058 points from the KAIST CHF data bank. This shows that it is reasonable to define the initial condition of quality and entrainment fraction at onset of annular flow (OAF) as the transition to annular flow regime and the equilibrium value, respectively, and the prediction error of the LFD model is dependent on the accuracy of the constitutive equations of droplet deposition and entrainment. In the modified Levy model, the CHF data are predicted with standard deviation (SD) of 14.0% and root mean square error (RMSE) of 14.1%. Meanwhile, in the present LFD model, which is based on the constitutive equations developed by Okawa et al., the entire data are calculated with SD of 17.1% and RMSE of 17.3%. Because of its qualitative prediction trend and universal calculation convergence, the present model was finally selected as the best LFD model to predict the CHF for narrow rectangular channels. For the assessment of the present LFD model for narrow rectangular channels, effective 284 data were selected. By using the present LFD model, these data are predicted with RMSE of 22.9% with the dryout criterion of zero -liquid film flow, but RMSE of 18.7% with rivulet formation model. This shows that the prediction error of the present LFD model for narrow rectangular channels is similar with that for circular channels. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] THEORETICAL CALCULATION OF THE CRITICAL HEAT FLUX IN ANNULAR UPWARD FLOW IN VERTICAL NARROW RECTANGULAR CHANNELS
    Du, Dongxiao
    Su, Guanghui
    Qiu, Suizheng
    [J]. ICONE17, VOL 4, 2009, : 311 - 319
  • [2] Critical heat flux prediction for saturated flow boiling of water in vertical tubes
    Celata, GP
    Mishima, K
    Zummo, G
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) : 4323 - 4331
  • [3] A study on prediction methods of the critical heat flux for upward flow in a vertical narrow rectangular channel
    Choi, Gil Sik
    Jeong, Yong Hoon
    Chang, Soon Heung
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2015, 294 : 103 - 116
  • [4] An evaluation of critical heat flux prediction methods for the upward flow in a vertical narrow rectangular channel
    Yan, Meiyue
    Ma, Zaiyong
    Pan, Liangming
    Liu, Wei
    He, Qingche
    Zhang, Rui
    Wu, Qi
    Xu, Wangtao
    [J]. PROGRESS IN NUCLEAR ENERGY, 2021, 140
  • [5] Heat transfer and pressure drop for flow boiling of water in narrow vertical rectangular channels
    Shuai, J
    Kulenovic, R
    Groll, M
    [J]. FIRST INTERNATIONAL CONFERENCE ON MICROCHANNELS AND MINICHANNELS, 2003, : 667 - 673
  • [6] Experimental and numerical study of flow boiling in a vertical upward narrow rectangular channel under low heat flux
    Cheng, Zheming
    Tao, Leren
    Jin, Cheng
    Cheng, Jian
    Li, Meng
    Zhang, Suhan
    Chang, Wanying
    [J]. APPLIED THERMAL ENGINEERING, 2024, 256
  • [7] CRITICAL HEAT-FLUX DURING NATURAL CONVECTIVE BOILING IN VERTICAL RECTANGULAR CHANNELS SUBMERGED IN SATURATED LIQUID
    MONDE, M
    KUSUDA, H
    UEHARA, H
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 300 - 303
  • [8] Critical heat flux correlation for subcooled boiling flow in narrow channels
    Kureta, M
    Akimoto, H
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (20) : 4107 - 4115
  • [9] Correlation for Flow Boiling Critical Heat Flux in Thin Rectangular Channels
    Tanaka, Fotoshi
    Hibiki, Takashi
    Mishima, Kaichiro
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2009, 131 (12): : 1 - 7
  • [10] EXPERIMENTAL INVESTIGATION OF SATURATED FLOW BOILING HEAT TRANSFER OF VERTICAL NARROW RECTANGULAR CHANNEL
    Chen, De-Qi
    Pan, Liang-ming
    Yuan, De-Wen
    [J]. ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 535 - 539