Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions

被引:52
|
作者
Muthalib, Makii [1 ]
Millet, Guillaume Y. [1 ,2 ]
Quaresima, Valentina [3 ]
Nosaka, Kazunori [1 ]
机构
[1] Edith Cowan Univ, Sch Exercise Biomed & Hlth Sci, Joondalup, WA 6027, Australia
[2] Univ St Etienne, Exercise Physiol Lab, St Etienne, France
[3] Univ Aquila, Dept Hlth Sci, I-67100 Laquila, Italy
关键词
tissue oxygenation index; oxidative metabolism; coefficient of variation; Bland-Altman plots; MUSCLE DEOXYGENATION KINETICS; STATISTICAL-METHODS; HANDGRIP EXERCISE; SKELETAL-MUSCLE; SPORTS-MEDICINE; REOXYGENATION; CONSUMPTION; HETEROGENEITY; FLOW;
D O I
10.1117/1.3309746
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman +/- 2 SD limits of agreement plots and coefficient of variation (CV). No significant (P > 0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within +/- 2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3309746]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison between electrically evoked and voluntary isometric contractions for biceps brachii muscle oxidative metabolism using near-infrared spectroscopy
    Muthalib, Makii
    Jubeau, Marc
    Millet, Guillaume Y.
    Maffiuletti, Nicola A.
    Nosaka, Kazunori
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (02) : 235 - 241
  • [2] Triaxial Mechanomyography of the Biceps Brachii Muscle during Sustained Submaximal Isometric Contractions
    Nogueira-Neto, Guilherme N.
    Scheeren, Eduardo M.
    Nohama, Percy
    Button, Vera Lucia S. N.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1502 - 1505
  • [3] Comparison between electrically evoked and voluntary isometric contractions for biceps brachii muscle oxidative metabolism using near-infrared spectroscopy
    Makii Muthalib
    Marc Jubeau
    Guillaume Y. Millet
    Nicola A. Maffiuletti
    Kazunori Nosaka
    [J]. European Journal of Applied Physiology, 2009, 107 : 235 - 241
  • [4] Tissue oxygenation by near-infrared spectroscopy and muscle blood flow during isometric contractions of the forearm
    Hicks, A
    McGill, S
    Hughson, RL
    [J]. CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1999, 24 (03): : 216 - 230
  • [5] Comparison of forearm muscle oxygenation dynamics during isometric and isotonic contractions monitored by near-infrared spectroscopy
    Cheung, A.
    Tu, L.
    Sahragard, F.
    Shadgan, B.
    [J]. BIOPHOTONICS IN EXERCISE SCIENCE, SPORTS MEDICINE, HEALTH MONITORING TECHNOLOGIES, AND WEARABLES, 2020, 11237
  • [6] Trial-to-trial Reliability of Biceps Brachii Mechanomyographic Responses during Isometric Contractions
    Miles, Patrick A.
    McMahon, Matthew J.
    Mookerjee, Swapan
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 190 - 191
  • [7] RELIABILITY OF NEAR-INFRARED SPECTROSCOPY FOR MEASURING INTERMITTENT HANDGRIP CONTRACTIONS IN SPORT CLIMBERS
    Balas, Jiri
    Kodejska, Jan
    Krupkova, Dominika
    Hannsmann, Johan
    Fryer, Simon
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2018, 32 (02) : 494 - 501
  • [8] Intensity-dependent EMG response for the biceps brachii during sustained maximal and submaximal isometric contractions
    Carr, Joshua C.
    Beck, Travis W.
    Ye, Xin
    Wages, Nathan P.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (09) : 1747 - 1755
  • [9] Intensity-dependent EMG response for the biceps brachii during sustained maximal and submaximal isometric contractions
    Joshua C. Carr
    Travis W. Beck
    Xin Ye
    Nathan P. Wages
    [J]. European Journal of Applied Physiology, 2016, 116 : 1747 - 1755
  • [10] Reliability of spike and turn variables of surface EMG during isometric voluntary contractions of the biceps brachii muscle
    Lee, Jin
    Jung, Min-Ye
    Kim, Sung-Hwan
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (01) : 119 - 127