Reliability analysis and comparison of long-distance HVAC and HVDC power transmission lines

被引:0
|
作者
Alekseeva, ND [1 ]
Bubnova, AV [1 ]
Chudny, VS [1 ]
Tikhodeev, NN [1 ]
机构
[1] HVDC Power Transmiss Res Inst, NIIPT, St Petersburg, Russia
关键词
HVDC and HVAC overhead lines; reliability; tower; pole; phase;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Double-circuit HVDC overhead power transmission lines rated at +/-500 to 750 kV with self-supporting towers and a long current-boosting capacity are capable to assure a maximum performance coefficient K-p of 0.996 (per 1000 km) in terms of electric energy transmitted. Much promise for densely populated areas is offered by quadrupolar transmission lines, i. e. those with double-circuit towers, calling for a minimum-width right-of-way. HVAC lines of a 500 to 1150 kV rating are inferior to their +/-500-750 kV counterparts as regards maneuverability, right-of-way width and performance coefficient (K-p = 0.98-0.99), because the line must be de-energized each time a phase, is damaged.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 50 条
  • [1] Application and Analysis of Long-distance EPON In Transmission Lines Monitoring System
    Huang, Hui
    Zhang, Hao
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 1583 - 1589
  • [2] HVDC over HVAC Power Transmission System: Fault Current Analysis and Effect Comparison
    Rahman, Md. Mizanur
    Rabbi, Md. Fazle
    Islam, Md. Khurshedul
    Rahman, F. M. Mahafugur
    [J]. 2014 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT 2014), 2014,
  • [3] Study on Ionized Field under Hybrid HVDC and HVAC Power Transmission Lines
    Yang, Jie
    Lu, Tiebing
    Zhao, Zhibin
    Gao, Changzheng
    [J]. 2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1076 - 1079
  • [4] Extra Long-Distance Bulk Power Transmission
    Lima, Antonio
    Dias, Robson
    [J]. 2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [5] Long-Distance DC Electrical Power Transmission
    Liu, Rongsheng
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2013, 29 (05) : 37 - 46
  • [6] Extra Long-Distance Bulk Power Transmission
    Dias, Robson
    Lima, Antonio
    Portela, Carlos
    Aredes, Mauricio
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1440 - 1448
  • [7] Long-distance Monitoring System on Galloping of Transmission Lines
    Sun, Chaohong
    Zhang, Zhanlong
    Liu, Huayong
    Mao, Yuxing
    Deng, Jun
    [J]. 2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1644 - +
  • [8] Power Balance Protection Using Long-distance Discretization Equation for EHV Transmission Lines
    Qiao, Zhanjun
    Li, Feng
    [J]. INTERNATIONAL JOURNAL OF GRID AND DISTRIBUTED COMPUTING, 2014, 7 (03): : 155 - 162
  • [9] Conditions of static stability of long-distance power transmission lines with controlled shunt reactors
    Ragozin, AA
    [J]. ELECTRICAL TECHNOLOGY, 1997, (02): : 73 - 79
  • [10] early ac power the first long-distance lines
    Allerhand, Adam
    [J]. IEEE POWER & ENERGY MAGAZINE, 2019, 17 (05): : 82 - 90