Detection of grouting defects in prestressed tendon ducts using distributed fiber optic sensors

被引:9
|
作者
Gong, Shilin [1 ]
Feng, Xin [1 ,2 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116023, Peoples R China
[2] Dalian Univ Technol, Key Lab Engn Disaster Prevent & Mitigat Liaoning, Dalian, Peoples R China
关键词
Grouting defect; detection; distributed fiber optic sensor; temperature; equivalent thermal conductivity; CONCRETE STRUCTURES;
D O I
10.1177/1475921719880318
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To compensate for the shortcomings of the existing point detection methods for grouting defects in prestressed tendon ducts, such as low detection efficiency, stringent detection environment, and easy omission of grouting defects, this article presents a distributed detection approach to detect the grouting defects in tendon ducts. The main objective of the research pertained to the development of a method for accurate identification and location of grouting defects and qualitative evaluation of the size of grouting defects using distributed fiber optic sensors with active heating. Using the thermal analysis of grouting defects in the tendon duct and the research on distributed fiber optic sensors measurement characteristics, our work proposed a method for identifying and locating grouting defects and explored the effect of the grouting defect length and the grouting compactness on the temperature rise of distributed fiber optic sensors. The feasibility of the proposed approach is evaluated through an experimental program. The experimental program involved use of heating distributed fiber optic sensors for the distributed measurement of temperature after the heating and detection of grouting defects in tendon ducts in a concrete beam. The results indicate that distributed fiber optic sensors can monitor the temperature distribution of the tendon duct during a temperature rise in real time. Grouting defects in the tendon duct can be quickly detected and located by identifying temperature anomalies in the temperature contour of the distributed fiber optic sensors. Furthermore, there is a linear relationship between the defect length and the abnormal temperature length on the distributed fiber optic sensors, and the defect length can be identified based on the abnormal temperature length obtained by the measurement. Plane-equivalent thermal conductivity can be used to evaluate the grouting compactness of the tendon duct. When the grouting compactness is greater than 70%, the smaller the plane-equivalent thermal conductivity is, the lower the grouting compactness is. The plane-equivalent thermal conductivity is basically the same when the grouting compactness is less than 70%.
引用
收藏
页码:1273 / 1286
页数:14
相关论文
共 50 条
  • [1] Application of the Phase Spectrum of Impact Echo in the Detection of Grouting Defects in the Tendon Ducts
    Chai, Wenhao
    Yang, Yaxun
    [J]. JOURNAL OF TESTING AND EVALUATION, 2024, 52 (04) : 1910 - 1925
  • [2] Experimental and Numerical Investigation of Cyclic Grouting Compactness in Prestressed Tendon Ducts
    Chen, Chulong
    Yang, Zeliang
    Yu, Shunxin
    Chen, Jinzhou
    [J]. ADVANCES IN CIVIL ENGINEERING, 2024, 2024
  • [3] Investigation of the applicability of infrared thermography detection of grouting voids in prestressed tendon ducts under hydration heat excitation
    Li, Shengli
    Gao, Xing
    Wang, Jiangfei
    Yang, Quan
    Jiang, Nan
    Zheng, Pengfei
    Cui, Can
    Han, Shanling
    Sun, Shiji
    [J]. NDT & E INTERNATIONAL, 2024, 143
  • [4] Distributed Fiber-Optic Sensors for Vibration Detection
    Liu, Xin
    Jin, Baoquan
    Bai, Qing
    Wang, Yu
    Wang, Dong
    Wang, Yuncai
    [J]. SENSORS, 2016, 16 (08)
  • [5] Pressure test of a prestressed concrete cylinder pipe using distributed fiber optic sensors: Instrumentation and results
    Li, Kangping
    Li, Yanlong
    Dong, Peng
    Wang, Zuorong
    Dou, Tiesheng
    Ning, Jinghua
    Dong, Xiaonong
    Si, Zheng
    [J]. ENGINEERING STRUCTURES, 2022, 270
  • [6] Mechanical properties of prestressed concrete cylinder pipe with broken wires using distributed fiber optic sensors
    Li, Kangping
    Li, Yanlong
    Dong, Peng
    Wang, Zuorong
    Dou, Tiesheng
    Ning, Jinghua
    Dong, Xiaonong
    Si, Zheng
    Wang, Jing
    [J]. ENGINEERING FAILURE ANALYSIS, 2022, 141
  • [7] Research on the Technology of Defects Detection in Prestressed Pipe Grouting
    He, Xiaoyu
    Liu, Jing
    Guo, Yilin
    [J]. TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 1312 - 1318
  • [8] Fiber optic distributed sensors
    Szustakowski, M
    Ciurapinski, WM
    [J]. OPTOELECTRONIC AND ELECTRONIC SENSORS II, 1997, 3054 : 12 - 17
  • [9] Impact detection, location and characterization using spatially weighted distributed fiber optic sensors
    Spillman, WB
    Huston, DR
    [J]. DISTRIBUTED AND MULTIPLEXED FIBER OPTIC SENSORS VI, 1996, 2838 : 143 - 152
  • [10] Detection of ground movements using soil-embedded distributed fiber optic sensors
    Hauswirth, D.
    Iten, M.
    Puzrin, A. M.
    [J]. GEOTECHNICAL AND GEOPHYSICAL SITE CHARACTERIZATION 4, VOLS I AND II, 2013, : 579 - 586