Study of a portable multi-parameter biochemical analyzer

被引:0
|
作者
Yu, YC [1 ]
Tang, F [1 ]
Wang, XH [1 ]
Chen, ZC [1 ]
Zhou, ZY [1 ]
机构
[1] Tsing Hua Univ, Inst Instrument Sci & Technol, Beijing 100084, Peoples R China
关键词
biochemical analyzer; self-monitoring; enzyme immobilizing; electrochemical detecting;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Portable biochemical analyzers are mainly used in the patients' self-monitoring and the medical institutions' rapid primary diagnosis. With the increased population of diseasedness and the enhancing health consciousness of people, they have found an ever-widening range of application. However, most of the present portable analyzers, no matter inland or outland, can only serve in the single-parameter detecting, and the accuracy of their test results, generally speaking, are not satisfied. In order to change this kind of status, the work described in this paper is focused on the development of a portable biochemical analyzer which is capable of testing 4 parameters including,blood sugar, cholesterol, uric acid and acetone body. Adopting the enzyme immobilizing technology and the electrochemical detecting method, the complete and practicable system design was proposed and the prototype was constructed as well. The comparing detecting experiments of partial parameters between our instrument and the large biochemical equipment indicate that out instrument operates steadily and its results correlate well.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 50 条
  • [1] Design of a multi-parameter substance analyzer
    Pérez, MA
    Campo, JC
    González, M
    López, P
    [J]. IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 1584 - 1589
  • [2] Portable Elevator Integration of Multi-parameter Measurement Instrument Design
    Wang, Pengfei
    Li, Zonghua
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHATRONICS, ROBOTICS AND AUTOMATION (ICMRA 2015), 2015, 15 : 311 - 314
  • [3] Measurement of beta-gamma coincidence with a multi-parameter analyzer system
    Yazdanpanah-Kejani, M.
    Abbasi, F.
    Lamehi-Rachti, M.
    Doost-Mohammadi, V.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 243 - 246
  • [4] Clustering reveals limits of parameter identifiability in multi-parameter models of biochemical dynamics
    Nienaltowski, Karol
    Wlodarczyk, Michal
    Lipniacki, Tomasz
    Komorowski, Michal
    [J]. BMC SYSTEMS BIOLOGY, 2015, 9
  • [5] Portable multi-parameter electrical impedance tomography for sleep apnea and hypoventilation monitoring: feasibility study
    Lee, Min Hyoung
    Jang, Geuk Young
    Kim, Young Eun
    Yoo, Pil Joong
    Wi, Hun
    Oh, Tong In
    Woo, Eung Je
    [J]. PHYSIOLOGICAL MEASUREMENT, 2018, 39 (12)
  • [6] Design and implementation of multi-parameter portable biological information measurement system
    Zhao Jinchuang
    Zhang Hao
    Fu Wenli
    Zou Xingxing
    [J]. PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 3762 - 3765
  • [7] Design of the serial data sampling system for portable multi-parameter monitor
    He, QH
    Wu, BM
    [J]. IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 495 - 496
  • [8] Some fast mono multi-processor configurations for a single multi-parameter multichannel analyzer
    Imperiale, C
    Imperiale, A
    [J]. MEASUREMENT, 2000, 27 (04) : 257 - 275
  • [9] Study on optical fiber multi-parameter sensor
    Liu, Tongyu
    Li, Zhen
    Meng, Xiangjun
    Zhao, Lin
    Wang, Fuqi
    Dong, Guofeng
    Wang, Jiqiang
    [J]. Tongxin Xuebao/Journal on Communications, 2020, 41 (02): : 66 - 73
  • [10] Design of Multi-parameter Portable Water Quality Detector Based on Wireless Network
    Junhua Xiong
    Tingling Wang
    [J]. Wireless Personal Communications, 2018, 102 : 1891 - 1904