Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region

被引:98
|
作者
Verellen, D
Linthout, N
VandenBerge, D
Bel, A
Storme, G
机构
[1] Free University Brussels (AZ-VUB), Academic Hospital, Department of Radiotherapy, Brussels
关键词
conformal radiation therapy; intensity modulation; tomotherapy; patient positioning; film dosimetry; alanine dosimetry; multileaf collimator;
D O I
10.1016/S0360-3016(97)00304-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The efficacy of a conventional, noninvasive fixation technique in combination with a commercially available system for conformal radiotherapy by intensity modulation of the treatment beam has been studied, Methods and Materials: A slice-by-slice are-rotation approach was used to deliver a conformal dose to the target and patient fixation was performed by means of thermoplastic casts, Eleven patients have been treated, of which 9 were for tumors of the head and neck region and 2 were for intracranial lesions. A procedure for target localization and verification of patient positioning suitable for this particular treatment technique has been developed based on the superposition of digitized portals with plots generated from the treatment-planning system, A dosimetric verification of the treatment procedure was performed with an anthropomorphic phantom: both absolute dose measurements (alanine and thermoluminescent detectors) and relative dose distribution measurements (film dosimetry) have been applied, The dose delivered outside the target has also been investigated. Results: The dose verification with the anthropomorphic phantom yielded a ratio between measured and predicted dose values of 1.0 for different treatment schedules and the calculated dose distribution agreed with the measured dose distribution, Day-to-day variations in patient setup of 0.3 cm (translations) and 2.0 degrees (rotations) were considered acceptable for this particular patient population, whereas the verification protocol allowed detection of 0.1 cm translational errors and 1.0 rotational errors, Conclusions: The noninvasive fixation technique in combination with an adapted verification protocol proved to be acceptable far conformal treatment of the head and neck region, Dose measurements, in turn, confirmed the predicted dose values to the target and organs at risk within uncertainty, Daily monitoring becomes mandatory if an accuracy superior to 0.1 cm and 1.0 degrees is required for patient setup, (C) 1997 Elsevier Science Inc.
引用
收藏
页码:99 / 114
页数:16
相关论文
共 50 条
  • [1] Intensity-modulated radiation therapy in the treatment of head and neck cancer
    Eisbruch, A
    [J]. NATURE CLINICAL PRACTICE ONCOLOGY, 2005, 2 (01): : 34 - 39
  • [2] Intensity-modulated radiation therapy in the treatment of head and neck cancer
    Avraham Eisbruch
    [J]. Nature Clinical Practice Oncology, 2005, 2 : 34 - 39
  • [3] Intensity-modulated radiation therapy in head and neck cancers: The Mallinckrodt experience
    Chao, KSC
    Low, DA
    Perez, CA
    Purdy, JA
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2000, 90 (02) : 92 - 103
  • [4] Intensity-modulated radiation therapy for head and neck carcinoma
    Gregoire, Vincent
    De Neve, Wilfried
    Eisbruch, Avraham
    Lee, Nancy
    Van den Weyngaert, Danielle
    Van Gestel, Dirk
    [J]. ONCOLOGIST, 2007, 12 (05): : 555 - 564
  • [5] Intensity-modulated radiation therapy for head and neck cancer
    Ozyigit G.
    Yang T.
    Chao K.S.C.
    [J]. Current Treatment Options in Oncology, 2004, 5 (1) : 3 - 9
  • [6] Intensity-modulated radiation therapy for head and neck cancer
    Chou, WW
    Puri, DR
    Lee, NY
    [J]. EXPERT REVIEW OF ANTICANCER THERAPY, 2005, 5 (03) : 515 - 521
  • [7] Intensity-modulated conformal radiation therapy in head and neck cancer. Treatment and associated quality control protocol
    Marchesi, V
    Lapeyre, M
    Aletti, P
    Graff, P
    Mege, A
    Noel, A
    Marchal, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S413 - S413
  • [8] Target localization and treatment verification for intensity modulated conformal radiation therapy of the head and neck region - The AZ-VUB experience
    Verellen, D
    Linthout, N
    Storme, G
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 : 19 - 27
  • [9] Intensity-modulated radiation therapy in head and neck cancers: An update
    Lee, Nancy
    Puri, Dev R.
    Blanco, Angel I.
    Chao, K. S. Clifford
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2007, 29 (04): : 387 - 400
  • [10] Intensity-modulated radiation therapy in the management of head and neck cancer
    Hong, TS
    Tomé, WA
    Harari, PM
    [J]. CURRENT OPINION IN ONCOLOGY, 2005, 17 (03) : 231 - 235