The impact of anatomical variables on haemodialysis tunnelled catheter replacement without fluoroscopy

被引:3
|
作者
Maggiani-Aguilera, Pablo [1 ,2 ]
Chavez-Iniguez, Jonathan S. [1 ,2 ]
Navarro-Gallardo, Joana G. [1 ,2 ]
Navarro-Blackaller, Guillermo [1 ,2 ]
Flores-Llamas, Alondra M. [1 ,2 ]
Pelayo-Retano, Tania [1 ,2 ]
Arellano-Delgado, Erendira A. [1 ,2 ]
Gonzalez-Montes, Violeta E. [1 ,2 ]
Yanowsky-Ortega, Ekatherina [1 ,2 ]
Raimann, Jochen G. [3 ]
Garcia-Garcia, Guillermo [1 ,2 ]
机构
[1] Hosp Civil Guadalajara Fray Antonio Alcalde, Nephrol Serv, Hosp 278, Guadalajara 44280, Jalisco, Mexico
[2] Univ Guadalajara, Hlth Sci Ctr, Guadalajara, Jalisco, Mexico
[3] Renal Res Inst, New York, NY USA
关键词
catheter dysfunction; catheter replacement; catheter tip position; haemodialysis; tunnelled catheter; CENTRAL VENOUS CATHETER; VASCULAR ACCESS; TIP; DYSFUNCTION; PLACEMENT; FISTULA;
D O I
10.1111/nep.13909
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aim Tunnelled haemodialysis (HD) catheters can be used instantly, but there are several anatomical variables that could impact it survival. This study aimed to examine the impact of different novel anatomic variables, with catheter replacement. Methods In a single-centre a prospective cohort in chronic kidney disease G5 patients were conducted. The primary outcome was to determine the factors associated with catheter replacement during the first 6-month of follow-up. All procedures were performed without fluoroscopy. Three anatomic regions for catheter tip position were established: considered as superior vena cava (SVC), cavo-atrial junction (CAJ) and mid-to deep atrium (MDA). Many other anatomical variables were measured. Catheter-related bloodstream infection was also included. Results Between January 2019 and January 2020 a total of 75 patients with tunnelled catheter insertion were analysed. Catheter replacement at 6-month occur in 10 (13.3%) patients. By multivariate analysis, the incorrect catheter tip position (SVC) (OR 1.23, 95% CI 1.07-1.42, p <.004), the presence of extrasystoles during the procedure (OR 0.88, 95% CI 0.78-0.98, p = .03), incorrect catheter tug (OR 1.31, 95% CI 1.10-1.55, p = .003), incorrect catheter top position (kinking; OR 1.40, 95% CI 1.04-1.88, p = .02) and catheter-related bloodstream infection (OR 2.60, 95% CI 2.09-3.25, p <.001) were the only variables associated with catheter replacement at 6-month follow-up. Conclusion The risk of catheter replacement at 6-month follow-up could be attenuated by avoiding incorrect catheter tug and top position, and by placing the vascular catheter tip in the CAJ and MDA.
引用
收藏
页码:824 / 832
页数:9
相关论文
共 50 条
  • [1] Comparing outcomes of tunnelled dialysis catheter insertions and exchanges with or without fluoroscopy
    Chang, Zi Yun
    Wong, Weng Kin
    Chan, Yiong Huak
    Khan, Behram A.
    Leo, Christopher C. H.
    [J]. JOURNAL OF VASCULAR ACCESS, 2022, 23 (03): : 443 - 449
  • [2] Fibrin sheath on a tunnelled haemodialysis catheter
    Peel, RK
    Turney, JH
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (05) : 1026 - 1026
  • [3] Impact of a permanent catheter tunnelled by haemodialysis in the jugular vein, an exceptional complication
    Merino, J. L.
    Galeano, C.
    Chinchilla, A.
    Sanchez, J.
    [J]. NEFROLOGIA, 2006, 26 (03): : 395 - 396
  • [4] Late atrial perforation from tunnelled haemodialysis catheter
    Banerjee, A.
    Bhowmick, K.
    Nayagam, M.
    Farrington, K.
    [J]. QJM-AN INTERNATIONAL JOURNAL OF MEDICINE, 2010, 103 (07) : 527 - 529
  • [5] Tunnelled vascular catheters for haemodialysis: the Tesio catheter.
    Ringrose, TR
    Mason, PD
    Winearls, CG
    Maxwell, PH
    [J]. KIDNEY INTERNATIONAL, 1999, 55 (05) : 2094 - 2094
  • [6] Tunnelled haemodialysis catheter and haemodialysis outcomes: a retrospective cohort study in Zagreb, Croatia
    Pasara, Vedran
    Maksimovic, Bojana
    Gunjaca, Mihaela
    Mihovilovic, Karlo
    Loncar, Andrea
    Kudumija, Boris
    Zabic, Igor
    Knotek, Mladen
    [J]. BMJ OPEN, 2016, 6 (05):
  • [7] TUNNELLED CENTRAL VENOUS HAEMODIALYSIS CATHETER TIP DESIGN AND RISK OF CATHETER DYSFUNCTION
    Lazarus, Benjamin
    Polkinghorne, Kevan
    Coggan, Sarah
    Gray, Nicholas
    Talaulikar, Girish
    Gallagher, Martin
    Kotwal, Sradha
    [J]. NEPHROLOGY, 2022, 27 : 23 - 23
  • [8] Tunnelled Central Venous Haemodialysis Catheter Tip Design and Risk of Catheter Dysfunction
    Lazarus, Ben
    Polkinghorne, Kevan
    Coggan, Sarah E.
    Gray, Nicholas A.
    Talaulikar, Girish S.
    Gallagher, Martin P.
    Kotwal, Sradha S.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 124 - 124
  • [9] Duration and complications of tunnelled central-venous haemodialysis catheter
    Clauss, M
    Rodersen, HP
    Floege, J
    von Dahl, J
    Corsten, F
    Janssen, U
    [J]. MEDIZINISCHE KLINIK, 2006, 101 (04) : A94 - A94
  • [10] UTILITY OF INTRALUMINAL THROMBOLYTIC THERAPY FOR TUNNELLED HAEMODIALYSIS CATHETER DYSFUNCTION
    Yaxley, J.
    Kurtkoti, J.
    Stockwell, L.
    [J]. NEPHROLOGY, 2020, 25 : 74 - 74