Effect of morbid obesity on kinetic of desflurane: wash-in wash-out curves and recovery times

被引:1
|
作者
La Colla, G.
La Colla, L.
Turi, S.
Poli, D.
Albertin, A.
Pasculli, N.
Bergonzi, P. C.
Gonfalini, M.
Ruggieri, F.
机构
[1] Univ Milan, IRCCS, H San Raffaele, Dept Anaesthesiol, I-20132 Milan, Italy
[2] Univ Modena, Dept Anaesthesia, I-41100 Modena, Italy
关键词
obesity; desflurane; remifentanil; kinetics;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Aim. The aim of this paper was to compare wash-in and wash-out curves of desflurane in morbidly obese and nonobese patients. Methods. Fourteen patients (7 obese and 7 nonobese) were studied. In the nonobese patients, anaesthesia was started by administering 2 mg/kg propofol bolus and a target controlled effect site concentration of remifentanil set at 2.5 ng/mL. Obese patients were intubated using a flexible fiberoptic bronchoscopic technique facilitated by a target controlled effect site concentration of remifentanil set at 2.5 ng/mL. After endotracheal intubation, general anaesthesia was started by administering a 1.5 mg/kg propofol bolus dose. Ten minutes after induction of anaesthesia, 4% desflurane was administered for 30 min. Desflurane kinetics was determined by collecting end-tidal samples from first breaths at 1, 5, 10, 15, 20, 25 and 30 min. At last skin suture, the end-tidal concentration of desflurane was recorded from 5 consecutive breaths before their discontinuation, then the end-tidal samples of the inhalational agent were collected at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5 and 5 min after terminating its administration. The period of time from discontinuation of desflurane to opening eyes, squeezing the observer's hand, extubation, stating the patients' name and providing date of birth was also recorded. Results. The FA/FI ratio was higher in the nonobese group from the 10th to the 15th min. Wash-out curves of desflurane and recovery times were similar. Conclusion. Our results show that desflurane provides similar kinetic and recovery profiles in obese and nonobese patients.
引用
收藏
页码:275 / 279
页数:5
相关论文
共 50 条
  • [1] Effects of obesity on wash-in and wash-out kinetics of sevoflurane
    Casati, A
    Marchetti, C
    Spreafico, E
    Mamo, D
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (03) : 243 - 245
  • [2] WASH-IN WASH-OUT AND SYSTEMIC EFFECTS IN EXTENDED PRISONERS DILEMMA
    TERHUNE, KW
    JOURNAL OF CONFLICT RESOLUTION, 1974, 18 (04) : 656 - 685
  • [3] INTERPRETATION OF 133XE LUNG WASH-IN AND WASH-OUT CURVES USING AN ANALOGUE COMPUTER
    MATTHEWS, CM
    DOLLERY, CT
    CLINICAL SCIENCE, 1965, 28 (03) : 573 - +
  • [4] Evaluation of wash-in and wash-out in the differential diagnosis of inflammatory and neoplastic nodules
    Bottinelli, O
    Campani, R
    Calliada, F
    Passamonti, M
    Carnevale, G
    RADIOLOGY, 1998, 209P : 309 - 309
  • [5] Evaluation of wash-in and wash-out in the differential diagnosis of thyroid nodules of different nature
    Calliada, F
    Campani, R
    Bottinelli, O
    Pallavicini, D
    Anguissola, R
    Madonia, L
    RADIOLOGY, 1998, 209P : 384 - 384
  • [6] UPTAKE AND ELIMINATION OF HALOTHANE IN DOGS - 2 OR MULTICOMPARTMENT SYSTEM .2. EVALUATION OF WASH-IN AND WASH-OUT CURVES
    BENEKENKOLMER, HH
    BURM, AG
    CRAMERS, CA
    RAMAKERS, JM
    VADER, HL
    BRITISH JOURNAL OF ANAESTHESIA, 1975, 47 (11) : 1169 - 1175
  • [7] ELIMINATION OF THE WASH-OUT EFFECT
    JOHNSON, M
    GONG, HY
    FREDDO, TF
    KAMM, RD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1123 - 1123
  • [8] HELIUM WASH-OUT CURVES IN POPULATION STUDIES
    VISSER, BF
    VANDERLENDE, R
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1975, 11 (01): : P46 - P50
  • [9] The suitability of EIT to estimate EELV in a clinical trial compared to oxygen wash-in/wash-out technique
    Karsten, Jan
    Meier, Torsten
    Iblher, Peter
    Schindler, Angela
    Paarmann, Hauke
    Heinze, Hermann
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 (01): : 59 - 64
  • [10] Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies
    Chon, D
    Simon, BA
    Beck, KC
    Shikata, H
    Saba, OI
    Won, CH
    Hoffman, EA
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 148 (1-2) : 65 - 83